23 research outputs found
HRFlexToT: A High Dynamic Range ASIC for Time-of-Flight Positron Emission Tomography
Time-of-Flight positron emission tomography scanners demand fast and efficient photo sensors and scintillators coupled to fast readout electronics. This article presents the high resolution flexible Time-over-Threshold (HRFlexToT), a 16-channel application-specific-integrated circuit for silicon photomultipliers (SiPM) anode readout manufactured using XFAB 0.18- \mu \text{m} CMOS technology. The main features of the HRFlexToT are a linear Time-over-Threshold with an extended dynamic range (10 bits) for energy measurement, low power consumption (â 3.5 mW/ch), and an excellent timing response. The experimental measurements show an energy linearity error of â 3% and an energy resolution of about 12% at 511 keV. Single-photon time resolution measurements performed using an Fondazione Bruno Kessler (FBK) SiPM NUV-HD ( 4 \times 4 mm2 pixel, 40- \mu \text{m} cell) and a Hamamatsu SiPM S13360-3050CS are around 142 and 167 ps full width at half maximum (FWHM), respectively. Coincidence time resolution (CTR) measurements with small cross-section pixelated crystals (LSO:Ce,Ca 0.4%, 2 \times 2 \times 5 mm3) coupled to the same Hamamatsu S13360-3050CS and FBK NUV-HD sensors yield a CTR of 117 ps and 119 ps, respectively. Measurements performed with a large cross-section monolithic crystal (LFS crystal measuring 25 \times 25 \times 20 mm3) and a Hamamatsu SiPM array S13361-6050NE-04 show a CTR of 324 ps FWHM after time-walk and time-skew correction
Development of the photomultiplier tube readout system for the first Large-Sized Telescope of the Cherenkov Telescope Array
The Cherenkov Telescope Array (CTA) is the next generation ground-based very
high energy gamma-ray observatory. The Large-Sized Telescope (LST) of CTA
targets 20 GeV -- 1 TeV gamma rays and has 1855 photomultiplier tubes (PMTs)
installed in the focal plane camera. With the 23 m mirror dish, the night sky
background (NSB) rate amounts to several hundreds MHz per pixel. In order to
record clean images of gamma-ray showers with minimal NSB contamination, a fast
sampling of the signal waveform is required so that the signal integration time
can be as short as the Cherenkov light flash duration (a few ns). We have
developed a readout board which samples waveforms of seven PMTs per board at a
GHz rate. Since a GHz FADC has a high power consumption, leading to large heat
dissipation, we adopted the analog memory ASIC "DRS4". The sampler has 1024
capacitors per channel and can sample the waveform at a GHz rate. Four channels
of a chip are cascaded to obtain deeper sampling depth with 4096 capacitors.
After a trigger is generated in a mezzanine on the board, the waveform stored
in the capacitor array is subsequently digitized with a low speed (33 MHz) ADC
and transferred via the FPGA-based Gigabit Ethernet to a data acquisition
system. Both a low power consumption (2.64 W per channel) and high speed
sampling with a bandwidth of 300 MHz have been achieved. In addition, in
order to increase the dynamic range of the readout we adopted a two gain system
achieving from 0.2 up to 2000 photoelectrons in total. We finalized the board
design for the first LST and proceeded to mass production. Performance of
produced boards are being checked with a series of quality control (QC) tests.
We report the readout board specifications and QC results.Comment: In Proceedings of the 34th International Cosmic Ray Conference
(ICRC2015), The Hague, The Netherlands. All CTA contributions at
arXiv:1508.0589
A High Dynamic Range ASIC for Time of Flight PET with monolithic crystals
The HRFlexToT is a 16-channel ASIC for SiPM anode readout designed for Positron Emission Tomography (PET) applications that features high dynamic range (>8 bits), low input impedance, common cathode connection, high speed and low power (~3.5 mW/ch). The ASIC has been manufactured using XFAB 0.18 mm CMOS technology. The main characteristics of the HRFlexToT, compared to its predecessor, are a new energy measurement readout providing a linear Time Over Threshold (ToT) with an extended dynamic range, lower power consumption and better timing response. Initial measurements show a linearity error below 3%. Single Photon Time Resolution (SPTR) measurements performed using a Hamamatsu MPPC S13360-3050CS (3x3 mm2 pixel, 50 umm cell) shows 30% improvement with respect to the previous version of the ASIC, setting this specification in the order of 141 ps FWHM and reducing 3 times power consumption. It is important to highlight that an SPTR of 141 ps FWHM is, according to the best of our knowledge, the best resolution achieved so far for this sensor. Coincidence Time Resolution (CTR) measurements are expected to be performed during 2018
Influenza vaccine effectiveness in reducing severe outcomes over six influenza seasons, a case-case analysis, Spain, 2010/11 to 2015/16
When influenza vaccination is ineffective in preventing influenza virus infection, it may still reduce the severity of influenza-associated disease. Here, we estimate the effect of influenza vaccination in preventing severe outcomes e.g. intensive care unit (ICU) admission and death, even thougHospital it did not prevent influenza virus infection and subsequent hospitalisation. An observational case-case epidemiological study was carried out in 12 sentinel hospitals in Catalonia (Spain) over six influenza seasons 2010/11-2015/16. Cases were individuals witHospital severe laboratory-confirmed influenza virus infection and aged 18 years and older. For eacHospital reported case we collected demographic, virological and clinical characteristics. Logistic regression was used to estimate the crude, adjusted odd ratios (aOR) and 95% confidence intervals (CI). Of 1,727 hospital-ised patients included in the study, 799 were female (46.7%), 591 (34.2%) were admitted to the ICU and 223 (12.9%) died. Influenza vaccination uptake was lower in cases that required ICU admission or died (21.2% vs 29.7%, p < 0.001). The adjusted influenza vaccination effectiveness in preventing ICU admission or deatHospital was 23% (95% CI: 1 to 40). In an analysis restricted to sex, age group and antiviral treatment, influenza vaccination had a positive effect on disease severity in all age groups and categories. We found that influenza vaccination reduced the severity of disease even in cases where it did not prevent infection and influenza-associated hospitalisation. Therefore, increased vaccination uptake may reduce complications, ICU admission and death