468 research outputs found

    A "SHort course Accelerated RadiatiON therapy" (SHARON) During and Beyond the COVID-19 Pandemic

    Get PDF
    The current pandemic situation posed significant problems for radiotherapy (RT) services. In addition to the need to treat COVID-positive patients, it is important to protect health workers and healthy patients from the infection. Although some restrictions are being removed, it is not sure when the pandemic is actually going to be definitively over. Radiation oncologists (ROs) will be forced to face the pandemic for an unknown time interval (1). A recent guideline has been published on the possibility of adapting RT strategies in all settings (2). Particularly along the first months of pandemic spread, hypofractionated RT schedules adequately managing different clinical settings have been proposed to reduce the number of interactions and contacts in hospitals (for both patients–patients and patients–RT personnel), while delivering effective treatments (3–5). Only few were specifically dedicated to palliative RT or particularly oriented to relevant palliative presentations (e.g., bone metastases) (6). With the aim of decreasing hospital contacts, it has been proposed to omit, or delay, or modify the usual prescribed RT regimens (6), more often for palliative settings. However, in the field of palliative RT any omission and delay can dramatically worsen patients’ quality of life. In fact, the proposal to omit palliative radiotherapy during the COVID-19 pandemic has not been widely accepted, with some authors being worried by its clinical and ethical implications (7, 8). We would like to draw attention to a RT regimen tested in different settings. This scheme of SHort course Accelerated RadiatiON therapy: “SHARON” allows to complete a palliative RT course in four sessions and in only 2 days, using a double daily fractionation

    Layer dependence of graphene-diamene phase transition in epitaxial and exfoliated few-layer graphene using machine learning

    Full text link
    The study of the nanomechanics of graphene −- and other 2D materials −- has led to the discovery of exciting new properties in 2D crystals, such as their remarkable in-plane stiffness and out of plane flexibility, as well as their unique frictional and wear properties at the nanoscale. Recently, nanomechanics of graphene has generated renovated interest for new findings on the pressure-induced chemical transformation of a few-layer thick epitaxial graphene into a new ultra-hard carbon phase, named diamene. In this work, by means of a machine learning technique, we provide a fast and efficient tool for identification of graphene domains (areas with a defined number of layers) in epitaxial and exfoliated films, by combining data from Atomic Force Microscopy (AFM) topography and friction force microscopy (FFM). Through the analysis of the number of graphene layers and detailed \r{A}-indentation experiments, we demonstrate that the formation of ultra-stiff diamene is exclusively found in 1-layer plus buffer layer epitaxial graphene on silicon carbide (SiC) and that an ultra-stiff phase is not observed in neither thicker epitaxial graphene (2-layer or more) nor exfoliated graphene films of any thickness on silicon oxide (SiO2_{2}).Comment: 30 pages, 7 figure

    Potential Applications and Limitations of Electronic Nose Devices for Plant Disease Diagnosis

    Get PDF
    Electronic nose technology has recently been applied to the detection of several plant diseases and pests, with promising results. However, in spite of its numerous advantages, including operational simplicity, non-destructivity, and bulk sampling, drawbacks include a low sensitivity and specificity in comparison with microbiological and molecular methods. A critical review of the use of an electronic nose for plant disease diagnosis and pest detection is presented, describing the instrumental and procedural advances of sensorial analysis, for the improvement of discrimination between healthy and infected or infested plants. In conclusion, the use of electronic nose technology is suggested to assist, direct, and optimise traditionally adopted diagnostic technique

    Potential application of pre-harvest LED interlighting to improve tomato quality and storability

    Get PDF
    Unidad de excelencia MarĂ­a de Maeztu CEX2019-000940-MGrowing conditions and agronomical inputs play a key role in determining fruit qualitative and nutraceutical traits at harvest and post-harvest. The hereby presented research investigated the effects of pre-harvest supplemental LED interlighting on post-harvest quality of hydroponically grown tomatoes (Solanum lycopersicum "Siranzo"). Three LED treatments, applied for 16 h d-1 (h 8.00-00.00), were added to natural sunlight and consisted of Red and Blue (RB), Red and Blue + Far-Red (FR), and Red and Blue + Far-Red at the end-of-day for 30 min (EOD), with an intensity of 180 ”mol m-2 s-1 for Red and Blue, plus 44 ”mol m-2 s-1 for Far-Red. A control treatment (CK), where plants were grown only with sunlight, was also considered. Fruits at red stage were selected and placed in a storage room at 13 °C in darkness. Fruit quality assessment was performed at harvest time and after one week of storage. RB and FR increased fruit firmness compared to CK, opening possible benefits toward reducing fruit losses during post-harvest handling. RB treated fruits also maintained a higher content of lycopene and ÎČ-carotene after the first week of storage. The study demonstrates that supplementary LED interlighting during greenhouse tomato cultivation may enhance storability and help preserve fruit nutritional properties during post-harvest

    Innovation in grapevine water status monitoring and drought adaptation: leaf angle and temperature regulation

    Get PDF
    Increase of frequency, duration, and intensity of drought and heatwave and related water and heat crops stress are among the principal effects of climate change. This paper reports: (i) the effect of calcite particle film (CaPF) as a mitigation strategy against heat stress in well-watered (WW) or in drought-stress (D) conditions; and (ii) response of leaf angle variation to stomatal conductance changes induced by drought stress of Aleatico grapevine cultivar. Results have showed that CaPF, under WW conditions, reduced leaf temperature, and increased gas exchange, but, under very severe water stress, CaPF treatment was ineffective. Leaf angle ranged from 70° (WW vines) to 100° (drought stressed vines) and showed a good fit (R2 =0.81) with stomatal conductance within the range of 0.25 – 0.05 mol m-2 s–1 proving it might be a reliable proxy of vine water status

    Red and Blue Light Differently Influence Actinidia chinensis Performance and Its Interaction with Pseudomonas syringae pv. Actinidiae

    Get PDF
    Light composition modulates plant growth and defenses, thus influencing plant–pathogen interactions. We investigated the effects of different light-emitting diode (LED) red (R) (665 nm) and blue (B) (470 nm) light combinations on Actinidia chinensis performance by evaluating biometric parameters, chlorophyll a fluorescence, gas exchange and photosynthesis-related gene expression. Moreover, the influence of light on the infection by Pseudomonas syringae pv. actinidiae (Psa), the etiological agent of bacterial canker of kiwifruit, was investigated. Our study shows that 50%R–50%B (50R) and 25%R–75%B (25R) lead to the highest PSII efficiency and photosynthetic rate, but are the least effective in controlling the endophytic colonization of the host by Psa. Monochromatic red light severely reduced ΩPSII, ETR, Pn, TSS and photosynthesis-related genes expression, and both monochromatic lights lead to a reduction of DW and pigments content. Monochromatic blue light was the only treatment significantly reducing disease symptoms but did not reduce bacterial endophytic population. Our results suggest that monochromatic blue light reduces infection primarily by modulating Psa virulence more than host plant defenses

    Personalized Automation of Treatment Planning for Linac-Based Stereotactic Body Radiotherapy of Spine Cancer

    Get PDF
    Purpose/Objective(s)Stereotactic ablative body radiotherapy (SBRT) for vertebral metastases is a challenging treatment process. Planning automation has recently reported the potential to improve plan quality and increase planning efficiency. We performed a dosimetric evaluation of the new Personalized engine implemented in Pinnacle3 for full planning automation of SBRT spine treatments in terms of plan quality, treatment efficiency, and delivery accuracy. Materials/MethodsThe Pinnacle3 treatment planning system was used to reoptimize six patients with spinal metastases, employing two separate automated engines. These two automated engines, the existing Autoplanning and the new Personalized, are both template-based algorithms that employ a wishlist to construct planning goals and an iterative technique to replicate the planning procedure performed by skilled planners. The boost tumor volume (BTV) was defined as the macroscopically visible lesion on RM examination, and the planning target volume (PTV) corresponds with the entire vertebra. Dose was prescribed according to simultaneous integrated boost strategy with BTV and PTV irradiated simultaneously over 3 fractions with a dose of 30 and 21 Gy, respectively. Dose-volume histogram (DVH) metrics and conformance indices were used to compare clinically accepted manual plans (MP) with automated plans developed using both Autoplanning (AP) and Personalized engines (Pers). All plans were evaluated for planning efficiency and dose delivery accuracy. ResultsFor similar spinal cord sparing, automated plans reported a significant improvement of target coverage and dose conformity. On average, Pers plans increased near-minimal dose D98% by 10.4% and 8.9% and target coverage D95% by 8.0% and by 4.6% for BTV and PTV, respectively. Automated plans provided significantly superior dose conformity and dose contrast by 37%-47% and by 4.6%-5.7% compared with manual plans. Overall planning times were dramatically reduced to about 15 and 23 min for Pers and AP plans, respectively. The average beam-on times were found to be within 3 min for all plans. Despite the increased complexity, all plans passed the 2%/2 mm gamma-analysis for dose verification. ConclusionAutomated planning for spine SBRT through the new Pinnacle3 Personalized engine provided an overall increase of plan quality in terms of dose conformity and a major increase in efficiency. In this complex anatomical site, Personalized strongly reduce the tradeoff between optimal accurate dosimetry and planning time

    Pain Relief after Stereotactic Radiotherapy of Pancreatic Adenocarcinoma: An Updated Systematic Review

    Get PDF
    Severe pain is frequent in patients with locally advanced pancreatic ductal adenocarcinoma (PDCA). Stereotactic body radiotherapy (SBRT) provides high local control rates in these patients. The aim of this review was to systematically analyze the available evidence on pain relief in patients with PDCA. We updated our previous systematic review through a search on PubMed of papers published from 1 January 2018 to 30 June 2021. Studies with full available text, published in English, and reporting pain relief after SBRT on PDCA were included in this analysis. Statistical analysis was carried out using the MEDCALC statistical software. All tests were two-sided. The I-2 statistic was used to quantify statistical heterogeneity (high heterogeneity level: >50%). Nineteen papers were included in this updated literature review. None of them specifically aimed at assessing pain and/or quality of life. The rate of analgesics reduction or suspension ranged between 40.0 and 100.0% (median: 60.3%) in six studies. The pooled rate was 71.5% (95% CI, 61.6-80.0%), with high heterogeneity between studies (Q(2) test: p < 0.0001; I-2 = 83.8%). The rate of complete response of pain after SBRT ranged between 30.0 and 81.3% (median: 48.4%) in three studies. The pooled rate was 51.9% (95% CI, 39.3-64.3%), with high heterogeneity (Q(2) test: p < 0.008; I-2 = 79.1%). The rate of partial plus complete pain response ranged between 44.4 and 100% (median: 78.6%) in nine studies. The pooled rate was 78.3% (95% CI, 71.0-84.5%), with high heterogeneity (Q(2) test: p < 0.0001; I-2 = 79.4%). A linear regression with sensitivity analysis showed significantly improved overall pain response as the EQD2 alpha/beta:10 increases (p: 0.005). Eight papers did not report any side effect during and after SBRT. In three studies only transient acute effects were recorded. The results of the included studies showed high heterogeneity. However, SBRT of PDCA resulted reasonably effective in producing pain relief in these patients. Further studies are needed to assess the impact of SBRT in this setting based on Patient-Reported Outcomes
    • 

    corecore