81 research outputs found

    Study and Optimization of a Non-Foster Circuit for the Design of Wideband Metasurfaces

    Get PDF
    International audienceIn this paper, a detailed study and the optimization of a Negative Impedance Converter (NIC) circuit are presented to increase the bandwidth of a passive metasurface. The design and optimization procedure take into account the biasing and the effect of the transistors. The optimization ensures that the load can be realized with passive components

    Effect of angiotensin-converting enzyme inhibitor and angiotensin receptor blocker initiation on organ support-free days in patients hospitalized with COVID-19

    Get PDF
    IMPORTANCE Overactivation of the renin-angiotensin system (RAS) may contribute to poor clinical outcomes in patients with COVID-19. Objective To determine whether angiotensin-converting enzyme (ACE) inhibitor or angiotensin receptor blocker (ARB) initiation improves outcomes in patients hospitalized for COVID-19. DESIGN, SETTING, AND PARTICIPANTS In an ongoing, adaptive platform randomized clinical trial, 721 critically ill and 58 non–critically ill hospitalized adults were randomized to receive an RAS inhibitor or control between March 16, 2021, and February 25, 2022, at 69 sites in 7 countries (final follow-up on June 1, 2022). INTERVENTIONS Patients were randomized to receive open-label initiation of an ACE inhibitor (n = 257), ARB (n = 248), ARB in combination with DMX-200 (a chemokine receptor-2 inhibitor; n = 10), or no RAS inhibitor (control; n = 264) for up to 10 days. MAIN OUTCOMES AND MEASURES The primary outcome was organ support–free days, a composite of hospital survival and days alive without cardiovascular or respiratory organ support through 21 days. The primary analysis was a bayesian cumulative logistic model. Odds ratios (ORs) greater than 1 represent improved outcomes. RESULTS On February 25, 2022, enrollment was discontinued due to safety concerns. Among 679 critically ill patients with available primary outcome data, the median age was 56 years and 239 participants (35.2%) were women. Median (IQR) organ support–free days among critically ill patients was 10 (–1 to 16) in the ACE inhibitor group (n = 231), 8 (–1 to 17) in the ARB group (n = 217), and 12 (0 to 17) in the control group (n = 231) (median adjusted odds ratios of 0.77 [95% bayesian credible interval, 0.58-1.06] for improvement for ACE inhibitor and 0.76 [95% credible interval, 0.56-1.05] for ARB compared with control). The posterior probabilities that ACE inhibitors and ARBs worsened organ support–free days compared with control were 94.9% and 95.4%, respectively. Hospital survival occurred in 166 of 231 critically ill participants (71.9%) in the ACE inhibitor group, 152 of 217 (70.0%) in the ARB group, and 182 of 231 (78.8%) in the control group (posterior probabilities that ACE inhibitor and ARB worsened hospital survival compared with control were 95.3% and 98.1%, respectively). CONCLUSIONS AND RELEVANCE In this trial, among critically ill adults with COVID-19, initiation of an ACE inhibitor or ARB did not improve, and likely worsened, clinical outcomes. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT0273570

    Genomic investigations of unexplained acute hepatitis in children

    Get PDF
    Since its first identification in Scotland, over 1,000 cases of unexplained paediatric hepatitis in children have been reported worldwide, including 278 cases in the UK1. Here we report an investigation of 38 cases, 66 age-matched immunocompetent controls and 21 immunocompromised comparator participants, using a combination of genomic, transcriptomic, proteomic and immunohistochemical methods. We detected high levels of adeno-associated virus 2 (AAV2) DNA in the liver, blood, plasma or stool from 27 of 28 cases. We found low levels of adenovirus (HAdV) and human herpesvirus 6B (HHV-6B) in 23 of 31 and 16 of 23, respectively, of the cases tested. By contrast, AAV2 was infrequently detected and at low titre in the blood or the liver from control children with HAdV, even when profoundly immunosuppressed. AAV2, HAdV and HHV-6 phylogeny excluded the emergence of novel strains in cases. Histological analyses of explanted livers showed enrichment for T cells and B lineage cells. Proteomic comparison of liver tissue from cases and healthy controls identified increased expression of HLA class 2, immunoglobulin variable regions and complement proteins. HAdV and AAV2 proteins were not detected in the livers. Instead, we identified AAV2 DNA complexes reflecting both HAdV-mediated and HHV-6B-mediated replication. We hypothesize that high levels of abnormal AAV2 replication products aided by HAdV and, in severe cases, HHV-6B may have triggered immune-mediated hepatic disease in genetically and immunologically predisposed children

    Lignes de propagation intégrées à fort facteur de qualité en technologie CMOS. Application à la synthèse de circuits passifs millimétriques

    No full text
    This work focuses on high-performance S-CPW (Shielded CoPlanar Waveguide) transmissionlines in classical CMOS integrated technologies for the millimeter-wave frequency band.Thanks to an important slow-wave phenomenon, the physical length of S-CPW decreases by afactor from 1.3 to 3.2 compared with classical transmission lines. Presenting also lowattenuation loss, the developed transmission lines show very high quality factor (higher than 40at 60 GHz). The precise study of the electromagnetism field leads to an electrical model forS-CPWs. This is the first model that takes the losses in this topology into account. Then, somebasic passive circuits designed with S-CPWs and characterized up to 110 GHz are presented invarious CMOS technologies. The low insertion losses and relative low surfaces of a powerdivider and a passband filter show the great interest of S-CPW to integrate compact passivecircuits in classical CMOS technologies at millimeter-wave frequencies.L’objectif de ces travaux est le développement en technologie intégrée standard d’une topologiede ligne de propagation optimisée en termes de pertes, d’encombrement et de facteur de qualitéaux fréquences millimétriques. Cette topologie nommée S-CPW (Shielded CoPlanarWaveguide) utilise le phénomène d’ondes lentes afin de miniaturiser longitudinalement la ligned’un facteur compris entre 1,3 et 3,2 par rapport à des topologies classiques. Disposantégalement de faibles pertes, les lignes développées présentent un facteur de qualité élevé parfoissupérieur à 40, à 60 GHz. A partir de l’étude du champ électromagnétique dans la structure, unmodèle électrique a été développé. C’est le premier modèle dans la littérature prenant en compteles pertes dans ce type de guide d’onde. Plusieurs dispositifs passifs intégrés réalisés avec deslignes S-CPW dans différentes technologies CMOS ont été caractérisés jusqu’à 110GHz. Lacompacité et les faibles pertes d’insertion obtenues pour la mesure de filtres à stubs et dediviseurs de puissance permettent de réussir l’intégration de circuits passifs compacts entechnologie microélectronique CMOS standard aux fréquences millimétriques

    Lignes de propagation intégrées à fort facteur de qualité en technologie CMOS. Application à la synthèse de circuits passifs millimétriques

    No full text
    This work focuses on high-performance S-CPW (Shielded CoPlanar Waveguide) transmissionlines in classical CMOS integrated technologies for the millimeter-wave frequency band.Thanks to an important slow-wave phenomenon, the physical length of S-CPW decreases by afactor from 1.3 to 3.2 compared with classical transmission lines. Presenting also lowattenuation loss, the developed transmission lines show very high quality factor (higher than 40at 60 GHz). The precise study of the electromagnetism field leads to an electrical model forS-CPWs. This is the first model that takes the losses in this topology into account. Then, somebasic passive circuits designed with S-CPWs and characterized up to 110 GHz are presented invarious CMOS technologies. The low insertion losses and relative low surfaces of a powerdivider and a passband filter show the great interest of S-CPW to integrate compact passivecircuits in classical CMOS technologies at millimeter-wave frequencies.L’objectif de ces travaux est le développement en technologie intégrée standard d’une topologiede ligne de propagation optimisée en termes de pertes, d’encombrement et de facteur de qualitéaux fréquences millimétriques. Cette topologie nommée S-CPW (Shielded CoPlanarWaveguide) utilise le phénomène d’ondes lentes afin de miniaturiser longitudinalement la ligned’un facteur compris entre 1,3 et 3,2 par rapport à des topologies classiques. Disposantégalement de faibles pertes, les lignes développées présentent un facteur de qualité élevé parfoissupérieur à 40, à 60 GHz. A partir de l’étude du champ électromagnétique dans la structure, unmodèle électrique a été développé. C’est le premier modèle dans la littérature prenant en compteles pertes dans ce type de guide d’onde. Plusieurs dispositifs passifs intégrés réalisés avec deslignes S-CPW dans différentes technologies CMOS ont été caractérisés jusqu’à 110GHz. Lacompacité et les faibles pertes d’insertion obtenues pour la mesure de filtres à stubs et dediviseurs de puissance permettent de réussir l’intégration de circuits passifs compacts entechnologie microélectronique CMOS standard aux fréquences millimétriques

    High quality factor integrated transmission lines in CMOS technology - Application to millimetre passive circuits

    No full text
    L’objectif de ces travaux est le développement en technologie intégrée standard d’une topologiede ligne de propagation optimisée en termes de pertes, d’encombrement et de facteur de qualitéaux fréquences millimétriques. Cette topologie nommée S-CPW (Shielded CoPlanarWaveguide) utilise le phénomène d’ondes lentes afin de miniaturiser longitudinalement la ligned’un facteur compris entre 1,3 et 3,2 par rapport à des topologies classiques. Disposantégalement de faibles pertes, les lignes développées présentent un facteur de qualité élevé parfoissupérieur à 40, à 60 GHz. A partir de l’étude du champ électromagnétique dans la structure, unmodèle électrique a été développé. C’est le premier modèle dans la littérature prenant en compteles pertes dans ce type de guide d’onde. Plusieurs dispositifs passifs intégrés réalisés avec deslignes S-CPW dans différentes technologies CMOS ont été caractérisés jusqu’à 110GHz. Lacompacité et les faibles pertes d’insertion obtenues pour la mesure de filtres à stubs et dediviseurs de puissance permettent de réussir l’intégration de circuits passifs compacts entechnologie microélectronique CMOS standard aux fréquences millimétriques.This work focuses on high-performance S-CPW (Shielded CoPlanar Waveguide) transmissionlines in classical CMOS integrated technologies for the millimeter-wave frequency band.Thanks to an important slow-wave phenomenon, the physical length of S-CPW decreases by afactor from 1.3 to 3.2 compared with classical transmission lines. Presenting also lowattenuation loss, the developed transmission lines show very high quality factor (higher than 40at 60 GHz). The precise study of the electromagnetism field leads to an electrical model forS-CPWs. This is the first model that takes the losses in this topology into account. Then, somebasic passive circuits designed with S-CPWs and characterized up to 110 GHz are presented invarious CMOS technologies. The low insertion losses and relative low surfaces of a powerdivider and a passband filter show the great interest of S-CPW to integrate compact passivecircuits in classical CMOS technologies at millimeter-wave frequencies

    Etude pharmacocinétique de l influence du sexe sur le profil plasmatique de la sélamectine chez le chien

    No full text
    La sélamectine est un antiparasitaire polyvalent développé pour le chien et le chat sous le nom déposé Stronghold®. Cet endectocide dérivé de la doramectine, est le premier membre de la famille des avermectines présentant une bonne sécurité d utilisation combinée à une bonne efficacité à la fois sur les parasites internes et externes des animaux de compagnie. Après une étude bibliographique des propriétés physico-chimiques et des indications thérapeutiques de la sélamectine, le travail de l auteur a consisté à explorer l influence du sexe sur la rémanence de cette molécule chez le chien grâce à une étude pharmacocinétique. Dix chiens de race Beagle répartis en deux groupes de cinq mâles et cinq femelles, ont été traités selon le même protocole : une application en spot-on d une dose de 6 mg/kg de sélamectine puis plusieurs prises de sang selon un calendrier précis. Les résultats présentés par l auteur dénotent l existence d une différence significative entre mâles et femelles concernant deux paramètres pharmacocinétiques : l AUC est plus grande chez les femelles (370,97 +- 146,87 ng.jour/mL) que chez les mâles (192,08 +- 63,85 ng.jour/mL) et la clairance est plus faible chez les femelles (18 185,00 +- 6 377 mL/kg/jour) que chez les mâles (34 596,00 +- 12 736 mL/kg/jour). L auteur expose ensuite les hypothèses pouvant justifier cette différence de rémanence entre chiens mâles et chiens femelles. Il envisage enfin l intérêt et les perspectives des résultats obtenus sur ce nouvel endectocide.TOULOUSE3-BU Santé-Centrale (315552105) / SudocTOULOUSE-EN Vétérinaire (315552301) / SudocSudocFranceF

    Etude pharmacocinétique de l influence du sexe sur le profil plasmatique de la sélamectine chez le chien

    No full text
    La sélamectine est un antiparasitaire polyvalent développé pour le chien et le chat sous le nom déposé Stronghold®. Cet endectocide dérivé de la doramectine, est le premier membre de la famille des avermectines présentant une bonne sécurité d utilisation combinée à une bonne efficacité à la fois sur les parasites internes et externes des animaux de compagnie. Après une étude bibliographique des propriétés physico-chimiques et des indications thérapeutiques de la sélamectine, le travail de l auteur a consisté à explorer l influence du sexe sur la rémanence de cette molécule chez le chien grâce à une étude pharmacocinétique. Dix chiens de race Beagle répartis en deux groupes de cinq mâles et cinq femelles, ont été traités selon le même protocole : une application en spot-on d une dose de 6 mg/kg de sélamectine puis plusieurs prises de sang selon un calendrier précis. Les résultats présentés par l auteur dénotent l existence d une différence significative entre mâles et femelles concernant deux paramètres pharmacocinétiques : l AUC est plus grande chez les femelles (370,97 +- 146,87 ng.jour/mL) que chez les mâles (192,08 +- 63,85 ng.jour/mL) et la clairance est plus faible chez les femelles (18 185,00 +- 6 377 mL/kg/jour) que chez les mâles (34 596,00 +- 12 736 mL/kg/jour). L auteur expose ensuite les hypothèses pouvant justifier cette différence de rémanence entre chiens mâles et chiens femelles. Il envisage enfin l intérêt et les perspectives des résultats obtenus sur ce nouvel endectocide.TOULOUSE3-BU Santé-Centrale (315552105) / SudocTOULOUSE-EN Vétérinaire (315552301) / SudocSudocFranceF
    corecore