30 research outputs found

    Access to

    Get PDF
    Objectives. Robotic surgery enables to perform coronary surgery totally endoscopically. This report describes our experience using the da Vinci system for coronary artery bypass surgery. Methods. Patients requiring single-or-double vessel revascularization were eligible. The procedure was performed without cardiopulmonary bypass on a beating heart. Results. From April 2004 to May 2008, fifty-six patients were enrolled in the study. Twenty-four patients underwent robotic harvesting of the mammary conduit followed by minimal invasive direct coronary artery bypass (MIDCAB), and twenty-three patients had a totally endoscopic coronary artery bypass (TECAB) grafting. Nine patients (16%) were converted to open techniques. The mean total operating time for TECAB was 372 ± 104 minutes and for MIDCAB was 220 ± 69 minutes. Followup was complete for all patients up to one year. There was one hospital death following MIDCAB and two deaths at follow up. Forty-eight patients had an angiogram or CT scan revealing occlusion or anastomotic stenoses (>50%) in 6 patients. Overall permeability was 92%. Conclusions. Robotic surgery can be performed with promising results

    Robotically-Assisted Coronary Artery Bypass Grafting

    Get PDF
    Objectives. Robotic surgery enables to perform coronary surgery totally endoscopically. This report describes our experience using the da Vinci system for coronary artery bypass surgery. Methods. Patients requiring single-or-double vessel revascularization were eligible. The procedure was performed without cardiopulmonary bypass on a beating heart. Results. From April 2004 to May 2008, fifty-six patients were enrolled in the study. Twenty-four patients underwent robotic harvesting of the mammary conduit followed by minimal invasive direct coronary artery bypass (MIDCAB), and twenty-three patients had a totally endoscopic coronary artery bypass (TECAB) grafting. Nine patients (16%) were converted to open techniques. The mean total operating time for TECAB was 372 ± 104 minutes and for MIDCAB was 220 ± 69 minutes. Followup was complete for all patients up to one year. There was one hospital death following MIDCAB and two deaths at follow up. Forty-eight patients had an angiogram or CT scan revealing occlusion or anastomotic stenoses (>50%) in 6 patients. Overall permeability was 92%. Conclusions. Robotic surgery can be performed with promising results

    Adult cardiac myocytes survive and remain excitable during long-term culture on synthetic supports

    Get PDF
    AbstractObjective: Cardiomyocytes can be transplanted successfully into skeletal and cardiac muscle. Our goal was to determine the feasibility of grafting cardiomyocytes onto various synthetic supports to create an excitable and viable tissue for implantation. Methods: Adult rat cardiomyocytes were cultured over an 8-week period onto different substitutes, including human glutaraldehyde-treated pericardium (n = 3), equine glutaraldehyde-treated pericardium (n = 3), polytetrafluoroethylene (n = 8), Dacron polyester (n = 16), and Vicryl polyglactin (n = 8). Results: Only the cells seeded on the Dacron survived, with the synthetic fibers colonized at 8 weeks. On the other supports, the number of myocytes progressively decreased from the first week, with their density (number of cells per square millimeter) being, after 20 days, 17 ± 2 on the polytetrafluoroethylene and 5 ± 1 on the human or equine pericardium compared with 45 ± 3 on the Dacron. After 8 weeks of culture on Dacron, the sarcomeric protein (sarcomeric α-actinin) was detected in all cells. In addition, the staining was regularly arranged and well aligned in a striated pattern. Spontaneous beating activity was obtained. Moreover, electrical stimulation of the cell preparation resulted in the generation of calcium transients, the frequency of which followed the frequency of the electrical stimulation. Conclusions: These results suggest that adult cardiac myocytes remain viable and excitable during long-term culture on a 3-dimensional Dacron support, which might constitute a new synthetic cardiac tissue. (J Thorac Cardiovasc Surg 2001;121:510-9

    ECMO for COVID-19 patients in Europe and Israel

    Get PDF
    Since March 15th, 2020, 177 centres from Europe and Israel have joined the study, routinely reporting on the ECMO support they provide to COVID-19 patients. The mean annual number of cases treated with ECMO in the participating centres before the pandemic (2019) was 55. The number of COVID-19 patients has increased rapidly each week reaching 1531 treated patients as of September 14th. The greatest number of cases has been reported from France (n = 385), UK (n = 193), Germany (n = 176), Spain (n = 166), and Italy (n = 136) .The mean age of treated patients was 52.6 years (range 16–80), 79% were male. The ECMO configuration used was VV in 91% of cases, VA in 5% and other in 4%. The mean PaO2 before ECMO implantation was 65 mmHg. The mean duration of ECMO support thus far has been 18 days and the mean ICU length of stay of these patients was 33 days. As of the 14th September, overall 841 patients have been weaned from ECMO support, 601 died during ECMO support, 71 died after withdrawal of ECMO, 79 are still receiving ECMO support and for 10 patients status n.a. . Our preliminary data suggest that patients placed on ECMO with severe refractory respiratory or cardiac failure secondary to COVID-19 have a reasonable (55%) chance of survival. Further extensive data analysis is expected to provide invaluable information on the demographics, severity of illness, indications and different ECMO management strategies in these patients

    Five-year results of the pilot trial of a sutureless valve

    No full text
    A prospective trial was designed to evaluate the feasibility of the Perceval sutureless aortic valve. We report the 5-year clinical and hemodynamic outcome.status: publishe

    Aortic valve replacement and concomitant procedures with the Perceval valve: results of European trials.

    No full text
    BACKGROUND The Perceval (Sorin Group, Milan, Italy) is a self-anchoring sutureless aortic valve prosthesis. We report the short- to midterm results of combined aortic valve replacement (AVR) with concomitant procedures in elderly patients undergoing operation as part of 3 consecutive prospective multicenter European studies. METHODS From April 2007 to February 2013, 243 patients (mean age, 79.7 ± 5.1 years; female patients, 61%; median EuroSCORE, 9%) underwent AVR with concomitant procedures. The concomitant procedures were coronary artery bypass grafting (CABG) (182 cases), septal myectomy (21 cases), CABG + other procedures (18 cases), and 22 other procedures. Primary and secondary end points included implant feasibility and safety (for mortality and morbidity) and efficacy (New York Heart Association [NYHA] class improvement and hemodynamic results) of the prosthesis at the different follow-up periods. Data were expressed as mean ± standard deviation. Kaplan-Meier analysis was performed for survival analysis. RESULTS Mean aortic cross-clamp and extracorporeal circulation (ECC) times were 50.7 ± 22.8 minutes and 78.9 ± 32.3 minutes, respectively. Thirty-day mortality was 2.1%. Mean postoperative gradient and effective orifice area were 10.1 ± 4.7 mm Hg and 1.5 ± 0.4 cm(2) and 8.9 ± 5.6 mm Hg and 1.6 ± 0.4 cm(2), respectively, at 1 year. There were early explantations, 4 of which resulted from paravalvular leaks. One additional valve explantation resulted from aortic root bleeding, probably caused by excessively extensive decalcification. In the late period, there was 1 mild paravalvular leak and no intravalvular insufficiency. No migration, dislodgement, or degeneration of the valve occurred during follow-up. Median follow-up was 444 days. CONCLUSIONS These trials confirm the safety and efficacy of the Perceval sutureless aortic valve, especially in elderly patients requiring AVR + concomitant procedures. In this patient group, sutureless valves may be advantageous compared to transcatheter valve implantations as concomitant procedures other than percutaneous coronary artery angioplasty are not always possible in the latter

    Carotid versus femoral access for transcatheter aortic valve implantation a propensity score inverse probability weighting study

    No full text
    International audienceObjectives - The transcarotid (TC) approach for transcatheter aortic valve implantation (TAVI) is potentially an optimal alternative to the transfemoral (TF) approach. Our goal was to compare the safety and efficacy of TC- and TF-TAVI. Methods - Patients who underwent TF-TAVI or TC-TAVI in the prospectively collected FRANCE TAVI registry between January 2013 and December 2015 were compared. Propensity score inverse probability weighting methods were employed to minimize the impact of bias related to non-random treatment assignment. Results - Of the 11 033 patients included in the current study, 10 598 (96%) underwent a TF-TAVI and 435 (4.1%) had a TC-TAVI. Patients in the TC-TAVI access group presented with a higher risk profile but were significantly younger. There were no differences in the perioperative and 2-year mortality rates after adjustment [odds ratio (OR) 1.02, 95% confidence interval (CI) 0.62-1.68; P = 0.99 and hazard ratio 1.03, 95% CI 0.7-1.35; P = 0.83). TC-TAVI was associated with a significant risk of stroke (OR 2.42, 95% CI 2.01-2.92; P < 0.001), ST-elevation myocardial infarction (OR 7.32, 95% CI 3.87-13.87; P < 0.001), infections (OR 2.36, 95% CI 2.04-2.71; P < 0.001), bleeding (OR 2.01, 95% CI 1.76-2.29; P < 0.001), renal failure (OR 2.23, 95% CI 1.90-2.60; P < 0.001) and need for dialysis (OR 2.36, 95% CI 2.01-2.76, P < 0.001). Conversely, TC-TAVI was not confirmed as a risk factor for pacemaker implantation after adjustment (OR 1.05, 95% CI 0.96-1.15; P < 0.28) and was a protective factor for vascular complications (OR 0.37, 95% CI 0.32-0.43; P < 0.001). Conclusions - TC-TAVI is a safe procedure compared to TF-TAVI, although it holds an increased risk of perioperative complications. It should be considered in case of non-femoral peripheral access as the second access choice, to increase the overall safety of TAVI procedures