166 research outputs found
Measuring the Impact of Oesophagectomy on Physical Functioning and Physical Activity Participation: a Prospective Study
Background: Oesophagectomy remains the only curative intervention for oesophageal cancer, with defined nutritional and health-related quality of life (HR-QOL) consequences. It follows therefore that there is a significant risk of decline in physical wellbeing with oesophagectomy however this has been inadequately quantified. This study prospectively examines change in physical functioning and habitual physical activity participation, from presurgery through 6-months post-oesophagectomy. Methods: Patients scheduled for oesophagectomy with curative intent were recruited. Key domains of physical functioning including exercise tolerance (six-minute walk test (6MWT)) and muscle strength (hand-grip strength), and habitual physical activity participation, including sedentary behaviour (accelerometry) were measured presurgery (T0) and repeated at 1-month (T1) and 6-months (T2) post-surgery. HR-QOL was measured using the EORTC-QOL C30. Results: Thirty-six participants were studied (mean age 62.4 (8.8) years, n = 26 male, n = 26 transthoracic oesophagectomy). Mean 6MWT distance decreased significantly from T0 to T1 (p = 0.006) and returned to T0 levels between T1 and T2 (p \u3c 0.001). Percentage time spent sedentary increased throughout recovery (p \u3c 0.001) and remained significantly higher at T2 in comparison to T0 (p = 0.003). In contrast, percentage time spent engaged in either light or moderate-to-vigorous intensity activity, all reduced significantly (p \u3c 0.001 for both) and remained significantly lower at T2 in comparison to T0 (p = 0.009 and p = 0.01 respectively). Patients reported deficits in multiple domains of HR-QOL during recovery including global health status (p = 0.04), physical functioning (p \u3c 0.001) and role functioning (p \u3c 0.001). Role functioning remained a clinically important 33-points lower than preoperative values at T2. Conclusion: Habitual physical activity participation remains significantly impaired at 6-months postoesophagectomy. Physical activity is a measurable and modifiable target for physical rehabilitation, which is closely aligned with patient-reported deficits in role functioning. Rehabilitation aimed at optimising physical health in oesophageal cancer survivorship is warranted
Immediate and late outcome of excimer laser and balloon coronary angioplasty: A quantitative angiographic comparison based on matched lesions
Objectives.This study sought to compare acute lumen changes and late lumen narrowing during and after excimer laser-assisted balloon angioplasty, measured by quantitative coronary angiography, with the immediate and long-term outcome of balloon angioplasty alone.Background.Although excimer laser coronary angioplasty is used as an adjunct or alternative to balloon angioplasty, limited comparative data exist regarding the immediate and long-term efficacy of excimer laser-assisted balloon angioplasty versus balloon angioplasty alone.Methods.A series of 53 lesions in 47 consecutive patients successfully treated with excimer laser-assisted balloon angioplasty were individually matched after completion of 6-month follow-up angiography with 53 successfully treated balloon angioplasty lesions according to vessel location, preprocedural minimal lumen diameter and reference diameter. Immediate and long-term angiographic results were assessed by an automated lumen contour detection algorithm.Results.Before intervention in the laser and balloon angioplasty groups, respectively, minimal lumen diameter (mean ± SD) was 0.73 ± 0.47 and 0.74 ± 0.46 mm, and reference diameter was 2.71 ± 0.42 and 2.72 ± 0.41 mm. Laser angioplasty was followed by adjunctive balloon dilation in 50 lesions. Mean balloon diameter at maximal inflation was similar in both treatment groups (2.61 ± 0.32 and 2.65 ± 0.38 mm, respectively), resulting in similar minimal lumen diameters after intervention of 1.77 ± 0.41 and 1.78 ± 0.34 mm, respectively. At follow-up angiography, minimal lumen diameter after excimer laser-assisted balloon angioplasty was 1.17 ± 0.63 mm, and that after balloon angioplasty alone was 1.46 ± 0.67 mm (p = 0.02). The angiographic restenosis rates at follow-up using the 50% diameter stenosis cutoff criterion were 57% and 34%, respectively (p = 0.02).Conclusions.Quantitative angiographic analysis of a matched group of 106 successfully treated coronary lesions showed a similar immediate outcome but reduced long-term efficacy of excimer laser-assisted balloon angioplasty compared with that after balloon angioplasty alone
Azimuthal anisotropy and correlations in p+p, d+Au and Au+Au collisions at 200 GeV
We present the first measurement of directed flow () at RHIC. is
found to be consistent with zero at pseudorapidities from -1.2 to 1.2,
then rises to the level of a couple of percent over the range . The latter observation is similar to data from NA49 if the SPS rapidities
are shifted by the difference in beam rapidity between RHIC and SPS.
Back-to-back jets emitted out-of-plane are found to be suppressed more if
compared to those emitted in-plane, which is consistent with {\it jet
quenching}. Using the scalar product method, we systematically compared
azimuthal correlations from p+p, d+Au and Au+Au collisions. Flow and non-flow
from these three different collision systems are discussed.Comment: Quark Matter 2004 proceeding, 4 pages, 3 figure
Azimuthal anisotropy: the higher harmonics
We report the first observations of the fourth harmonic (v_4) in the
azimuthal distribution of particles at RHIC. The measurement was done taking
advantage of the large elliptic flow generated at RHIC. The integrated v_4 is
about a factor of 10 smaller than v_2. For the sixth (v_6) and eighth (v_8)
harmonics upper limits on the magnitudes are reported.Comment: 4 pages, 6 figures, contribution to the Quark Matter 2004 proceeding
All-optical switching and strong coupling using tunable whispering-gallery-mode microresonators
We review our recent work on tunable, ultrahigh quality factor
whispering-gallery-mode bottle microresonators and highlight their applications
in nonlinear optics and in quantum optics experiments. Our resonators combine
ultra-high quality factors of up to Q = 3.6 \times 10^8, a small mode volume,
and near-lossless fiber coupling, with a simple and customizable mode structure
enabling full tunability. We study, theoretically and experimentally, nonlinear
all-optical switching via the Kerr effect when the resonator is operated in an
add-drop configuration. This allows us to optically route a single-wavelength
cw optical signal between two fiber ports with high efficiency. Finally, we
report on progress towards strong coupling of single rubidium atoms to an
ultra-high Q mode of an actively stabilized bottle microresonator.Comment: 20 pages, 24 figures. Accepted for publication in Applied Physics B.
Changes according to referee suggestions: minor corrections to some figures
and captions, clarification of some points in the text, added references,
added new paragraph with results on atom-resonator interactio
Strange Resonance Production in p+p and Au+Au Collisions at RHIC Energies
Resonance yields and spectra from elementary p+p and Au+Au collisions at
200 GeV from the STAR experiment at RHIC are presented
and discussed in terms of chemical and thermal freeze-out conditions. Thermal
models do not adequately describe the yields of the resonance production in
central Au+Au collisions. The approach to include elastic hadronic interactions
between chemical freeze-out and thermal freeze-out suggests a time of 5 fm/c.Comment: 4 pages, 7 figures, proceedings of the Quark Matter 2004, in Oakland,
California, to be published in Journal of Physics G: Nuclear and Particle
Physic
Identified particles at large transverse momenta in STAR in Au+Au collisions @ sqrt(s_NN) = 200 GeV
We report measurements of the ratios of identified hadrons (pi,K,p,Lambda) in
Au+Au collisions at sqrt(s_NN) = 200 GeV as a function of both collision
centrality and transverse momentum (p_T). Ratios of anti-baryon to baryon
yields are independent of p_T within 2<p_T <6 GeV/c indicating that, for such a
range, our measurements are inconsistent with theoretical pQCD calculations
predicting a decrease due to a stronger contribution from valence quark
scattering. For both strange and non-strange species, a strong baryon
enhancement relative to meson yields is observed as a function of collision
centrality in this intermediate p_T region, leading to p/pi and Lambda/K ratios
greater than unity. The nuclear modification factor, R_cp (central relative to
peripheral collisions), is used to illustrate the interplay between jet
quenching and hadron production. The physics implications of these measurements
are discussed with reference to different theoretical models.Comment: 5 pages, 4 figures. Proceedings of Quark Matter 2004 Conference, Jan
2004, Oakland, USA. Submitted to Journal of Physics
High- electron distributions in d+Au and p+p collisions at RHIC
We present preliminary measurements of electron and positron spectra in d+Au
and p+p collisions at GeV for GeV/c.
These measurements were carried out using the STAR Time Projection Chamber
(TPC) and the Barrel Electromagnetic calorimeter (EMC). Overall hadron
rejection factors in the range of have been achieved. In this work we
describe the measurement technique used to discriminate electrons from hadrons
and compare the results for single electron spectra with Pythia based pQCD
calculations for electrons from heavy-quark semi-leptonic decays.Comment: Quark Matter 2004 conference proceeding
- …