401 research outputs found
Preparing For Extended Field Tests of the Intelligent Water System
The Intelligent Water System, which improves access to clean water by autonomously monitoring and reporting on the health of hand pumps in developing countries, has been under development for several years. This development has included short-term prototype field tests in several countries. The design has matured to the point that an extended field trial to demonstrate performance and reliability has been requested by our client. In light of this, the team has implemented design changes to address issues from our most recent prototype field test and begun manufacture of the first five systems intended for installation in Burkina Faso. This poster highlights the code changes enabling more accurate determination of the volume of water pumped and the simplified mounting of the systemās Handle Motion Sensor.https://mosaic.messiah.edu/engr2021/1006/thumbnail.jp
Terrestrial locomotion of the northern elephant seal (Mirounga angustirostris): limitation of large aquatically adapted seals on land?
The aquatic specializations of phocid seals have restricted their ability to locomote on land. The amphibious northern elephant seal, Mirounga angustirostris, is the second largest phocid seal in the world, with males reaching 2700 kg. Although elephant seals are proficient swimmers and deep divers, their extreme size and aquatic specializations limit terrestrial movement. The kinematics of terrestrial locomotion in northern elephant seals were analyzed from video recordings of animals observed on the beach of AnĢ o Nuevo State Reserve, CA, USA. The seals moved using a series of rhythmic undulations produced by dorsoventral spinal flexion. The traveling spinal wave moved anteriorly along the dorsal margin of the body with the chest, pelvic region and foreflippers serving as the main points of contact with the ground. The hindflippers were not used. The spinal wave and foreflippers were used to lift the chest off the ground as the body was pushed forward from the pelvis as the foreflippers were retracted to pull the body forward. Seals moved over land at 0.41ā2.56 m sā1 (0.12ā0.71 body lengths sā1 ). The frequency and amplitude of spinal flexions both displayed a direct increase with increasing speed. The duty factor for the pelvic region decreased with increasing velocity while the duty factor of the foreflipper remained constant. Kinematic data for elephant seals and other phocids were used in a biomechanical model to calculate the mechanical energy expended during terrestrial locomotion. The elephant seals were found to expend more energy when traveling over land for their size than smaller phocids. The unique method of terrestrial movement also exhibited greater energy expenditure on land than values for large quadrupeds. The trade-off for the northern elephant seal is that its massive size and morphology have well adapted it to an aquatic existence but limited its locomotor performance (i.e. speed, endurance) on land
Multiplex SNP Discrimination
Multiplex hybridization reactions of perfectly matched duplexes and duplexes containing a single basepair mismatch (SNPs) were investigated on DNA microarrays. Effects of duplex length, G-C percentage, and relative position of the SNP on duplex hybridization and SNP resolution were determined. Our theoretical model of multiplex hybridization accurately predicts observed results and implicates target concentration as a critical variable in multiplex SNP detection
DNA multiplex hybridization on microarrays and thermodynamic stability in solution: a direct comparison
Hybridization intensities of 30 distinct short duplex DNAs measured on spotted microarrays, were directly compared with thermodynamic stabilities measured in solution. DNA sequences were designed to promote formation of perfect match, or hybrid duplexes containing tandem mismatches. Thermodynamic parameters ĪHĀ°, ĪSĀ° and ĪGĀ° of melting transitions in solution were evaluated directly using differential scanning calorimetry. Quantitative comparison with results from 63 multiplex microarray hybridization experiments provided a linear relationship for perfect match and most mismatch duplexes. Examination of outliers suggests that both duplex length and relative position of tandem mismatches could be important factors contributing to observed deviations from linearity. A detailed comparison of measured thermodynamic parameters with those calculated using the nearest-neighbor model was performed. Analysis revealed the nearest-neighbor model generally predicts mismatch duplexes to be less stable than experimentally observed. Results also show the relative stability of a tandem mismatch is highly dependent on the identity of the flanking WatsonāCrick (w/c) base pairs. Thus, specifying the stability contribution of a tandem mismatch requires consideration of the sequence identity of at least four base pair units (tandem mismatch and flanking w/c base pairs). These observations underscore the need for rigorous evaluation of thermodynamic parameters describing tandem mismatch stability
Resolving the inner jet structure of 1924-292 with the EVENT HORIZON TELESCOPE
We present the first 1.3 mm (230 GHz) very long baseline interferometry model
image of an AGN jet using closure phase techniques with a four-element array.
The model image of the quasar 1924-292 was obtained with four telescopes at
three observatories: the James Clerk Maxwell Telescope (JCMT) on Mauna Kea in
Hawaii, the Arizona Radio Observatory's Submillimeter Telescope (SMT) in
Arizona, and two telescopes of the Combined Array for Research in
Millimeterwave Astronomy (CARMA) in California in April 2009. With the greatly
improved resolution compared with previous observations and robust closure
phase measurement, the inner jet structure of 1924-292 was spatially resolved.
The inner jet extends to the northwest along a position angle of at
a distance of 0.38\,mas from the tentatively identified core, in agreement with
the inner jet structure inferred from lower frequencies, and making a position
angle difference of with respect to the cm-jet. The size of
the compact core is 0.15\,pc with a brightness temperature of
\,K. Compared with those measured at lower frequencies, the
low brightness temperature may argue in favor of the decelerating jet model or
particle-cascade models. The successful measurement of closure phase paves the
way for imaging and time resolving Sgr A* and nearby AGN with the Event Horizon
Telescope.Comment: 6 pages, 4 figures, accepted for publication in ApJ
1.3 mm Wavelength VLBI of Sagittarius A*: Detection of Time-Variable Emission on Event Horizon Scales
Sagittarius A*, the ~4 x 10^6 solar mass black hole candidate at the Galactic
Center, can be studied on Schwarzschild radius scales with (sub)millimeter
wavelength Very Long Baseline Interferometry (VLBI). We report on 1.3 mm
wavelength observations of Sgr A* using a VLBI array consisting of the JCMT on
Mauna Kea, the ARO/SMT on Mt. Graham in Arizona, and two telescopes of the
CARMA array at Cedar Flat in California. Both Sgr A* and the quasar calibrator
1924-292 were observed over three consecutive nights, and both sources were
clearly detected on all baselines. For the first time, we are able to extract
1.3 mm VLBI interferometer phase information on Sgr A* through measurement of
closure phase on the triangle of baselines. On the third night of observing,
the correlated flux density of Sgr A* on all VLBI baselines increased relative
to the first two nights, providing strong evidence for time-variable change on
scales of a few Schwarzschild radii. These results suggest that future VLBI
observations with greater sensitivity and additional baselines will play a
valuable role in determining the structure of emission near the event horizon
of Sgr A*.Comment: 8 pages, submitted to ApJ
C5 Palsy After Cervical Spine Surgery: A Multicenter Retrospective Review of 59 Cases.
STUDY DESIGN: A multicenter, retrospective review of C5 palsy after cervical spine surgery.
OBJECTIVE: Postoperative C5 palsy is a known complication of cervical decompressive spinal surgery. The goal of this study was to review the incidence, patient characteristics, and outcome of C5 palsy in patients undergoing cervical spine surgery.
METHODS: We conducted a multicenter, retrospective review of 13ā946 patients across 21 centers who received cervical spine surgery (levels C2 to C7) between January 1, 2005, and December 31, 2011, inclusive. P values were calculated using 2-sample t test for continuous variables and Ļ(2) tests or Fisher exact tests for categorical variables.
RESULTS: Of the 13ā946 cases reviewed, 59 patients experienced a postoperative C5 palsy. The incidence rate across the 21 sites ranged from 0% to 2.5%. At most recent follow-up, 32 patients reported complete resolution of symptoms (54.2%), 15 had symptoms resolve with residual effects (25.4%), 10 patients did not recover (17.0%), and 2 were lost to follow-up (3.4%).
CONCLUSION: C5 palsy occurred in all surgical approaches and across a variety of diagnoses. The majority of patients had full recovery or recovery with residual effects. This study represents the largest series of North American patients reviewed to date
Epidural Hematoma Following Cervical Spine Surgery.
STUDY DESIGN: A multicentered retrospective case series.
OBJECTIVE: To determine the incidence and circumstances surrounding the development of a symptomatic postoperative epidural hematoma in the cervical spine.
METHODS: Patients who underwent cervical spine surgery between January 1, 2005, and December 31, 2011, at 23 institutions were reviewed, and all patients who developed an epidural hematoma were identified.
RESULTS: A total of 16ā582 cervical spine surgeries were identified, and 15 patients developed a postoperative epidural hematoma, for a total incidence of 0.090%. Substantial variation between institutions was noted, with 11 sites reporting no epidural hematomas, and 1 site reporting an incidence of 0.76%. All patients initially presented with a neurologic deficit. Nine patients had complete resolution of the neurologic deficit after hematoma evacuation; however 2 of the 3 patients (66%) who had a delay in the diagnosis of the epidural hematoma had residual neurologic deficits compared to only 4 of the 12 patients (33%) who had no delay in the diagnosis or treatment (P = .53). Additionally, the patients who experienced a postoperative epidural hematoma did not experience any significant improvement in health-related quality-of-life metrics as a result of the index procedure at final follow-up evaluation.
CONCLUSION: This is the largest series to date to analyze the incidence of an epidural hematoma following cervical spine surgery, and this study suggest that an epidural hematoma occurs in approximately 1 out of 1000 cervical spine surgeries. Prompt diagnosis and treatment may improve the chance of making a complete neurologic recovery, but patients who develop this complication do not show improvements in the health-related quality-of-life measurements
Time and event-specific deep learning for personalized risk assessment after cardiac perfusion imaging
Standard clinical interpretation of myocardial perfusion imaging (MPI) has proven prognostic value for predicting major adverse cardiovascular events (MACE). However, personalizing predictions to a specific event type and time interval is more challenging. We demonstrate an explainable deep learning model that predicts the time-specific risk separately for all-cause death, acute coronary syndrome (ACS), and revascularization directly from MPI and 15 clinical features. We train and test the model internally using 10-fold hold-out cross-validation (nā=ā20,418) and externally validate it in three separate sites (nā=ā13,988) with MACE follow-ups for a median of 3.1 years (interquartile range [IQR]: 1.6, 3.6). We evaluate the model using the cumulative dynamic area under receiver operating curve (cAUC). The best model performance in the external cohort is observed for short-term prediction - in the first six months after the scan, mean cAUC for ACS and all-cause death reaches 0.76 (95% confidence interval [CI]: 0.75, 0.77) and 0.78 (95% CI: 0.78, 0.79), respectively. The model outperforms conventional perfusion abnormality measures at all time points for the prediction of death in both internal and external validations, with improvement increasing gradually over time. Individualized patient explanations are visualized using waterfall plots, which highlight the contribution degree and direction for each feature. This approach allows the derivation of individual event probability as a function of time as well as patient- and event-specific risk explanations that may help draw attention to modifiable risk factors. Such a method could help present post-scan risk assessments to the patient and foster shared decision-making
- ā¦