131 research outputs found
Comparison of the Gen-Probe Aptima HIV-1 and Abbott HIV-1 qualitative assays with the Roche Amplicor HIV-1 DNA assay for early infant diagnosis using dried blood spots
The current gold standard for infant diagnosis of HIV-1 is the Roche Amplicor Qualitative DNA assay, but it is being phased out
Comparison of Blood Collected in Acid-Citrate-Dextrose and EDTA for Use in Human Immunodeficiency Virus Peripheral Blood Mononuclear Cell Cultures
Paired blood samples collected in acid-citrate-dextrose and EDTA were compared for human immunodeficiency virus (HIV) infectivity on the day of collection or after 1 day of storage at room temperature. No significant differences between the anticoagulants were observed. Culture positivity was significantly associated with HIV RNA viral loads for both anticoagulants
HIV-1 viral load and phenotypic antiretroviral drug resistance assays based on reverse transcriptase activity in comparison to amplification based HIV-1 RNA and genotypic assays
Amplification based HIV-1 viral load and genotypic resistance assays are expensive, technologically complex and may be difficult to implement in resource limited settings. Inexpensive, simpler assays are urgently needed
Recommended from our members
Baseline resistance to nucleoside reverse transcriptase inhibitors fails to predict virologic response to combination therapy in children (PACTG 338)
BACKGROUND: The association between baseline drug resistance mutations and subsequent increase in viral failure has not been established for HIV-infected children. We evaluated drug resistance mutations at 39 codon sites (21 protease inhibitor (PI) resistant codons and 18 nucleoside reverse transcriptase inhibitor (NRTI) resistant codons) for 92 clinically stable NRTI-experienced, PI-naive HIV-infected children 2 to 17 years of age who were initiating new therapy with ritonavir plus zidovudine (ZDV) and lamivudine or plus stavudine. The association between baseline drug resistance mutations and subsequent viral failure after 12 and 24 weeks of highly active antiretroviral therapy (HAART) was studied. RESULTS: There were few primary PI associated mutations in this PI-naïve population, but 84% had NRTI mutations – codons 215 (66%), 41 (42%), 67 (37%), 210 (33%) and 70 (32%). None of the specific baseline drug resistance mutations were associated with a higher rate of virologic failure after 12 or 24 weeks of HAART. Median week 12 viral load decreased as the total number of NRTI mutations at baseline increased (P = 0.006). Specifically, a higher level of baseline ZDV resistance mutation was associated with a decrease in viral failure after 12 weeks on a ZDV-containing HAART regimen (P = 0.017). CONCLUSION: No increase was seen in the rate of viral failure after HAART associated with the presence of resistance mutations at baseline. This paradoxical result may be due to adherence, replicative capacity, or ZDV hypersusceptibility to the new regimen
Association of CD4 Cell Depletion and Elevated Blood and Seminal Plasma Human Immunodeficiency Virus Type 1 (HIV-1) RNA Concentrations with Genital Ulcer Disease in HIV-1-Infected Men in Malawi
CD4 cell counts and blood plasma and seminal plasma human immunodeficiency virus type 1 (HIV-1) concentrations were compared in HIV-1 RNA-seropositive men with urethritis and with or without genital ulcer disease (GUD). GUD was associated with lower CD4 cell counts (median, 258 vs. 348/μL) and increased blood plasma HIV-1 RNA (median, 240 × 103 vs. 79.4 × 103 copies/ mL). Men with nongonococcal urethritis and GUD shed significantly greater quantities of HIV-1 in semen (median, 195 × 103 vs. 4.0 × 103 copies/mL) than men with nongonococcal urethritis without GUD. These levels decreased ∽4-fold following antibiotic therapy. The results indicate an association between GUD and increased blood HIV-1 RNA levels. Increased HIV-1 in semen was demonstrated in some men with GUD; such an increase could lead to increased transmission, thus complicating interpretation of the role of the genital ulcer itself in the infectiousness of HIV. Reasons for increased HIV RNA in semen in men with GUD remain to be determine
HIV-1 viral load assays for resource-limited settings: Authors' reply [5]
The authors discuss studies on the low-cost viral load assays that are currently available and their potential for use in resource-limited settings
High Levels of Human Immunodeficiency Virus Type 1 in Blood and Semen of Seropositive Men in Sub-Saharan Africa
High levels of human immunodeficiency virus type 1 (HIV-1) replication, as reflected in HIV-1 RNA concentrations in blood and semen, probably contribute to both rapid disease progression and enhanced sexual transmission. Semen and blood were collected from 49 Malawian and 61 US and Swiss (US/Swiss) HIV-1.seropositive men with similar CD4 cell counts and no urethritis or exposure to antiretroviral drugs. Median seminal plasma and blood plasma HIV-1 RNA concentrations were > 3-fold (P = .034) and 5-fold (P = .0003) higher, respectively, in the Malawian men. Similar differences were observed in subsets of the Malawian and US/Swiss study groups matched individually for CD4 cell count (P = .035 and P <.002, respectively). These observations may help explain the high rates of HIV-1 sexual transmission and accelerated HIV-1 disease progression in sub-Saharan Afric
Acute HIV infection among pregnant women in Malawi
There are limited data on acute HIV infection (AHI) prevalence during pregnancy
Systematic review of the performance of HIV viral load technologies on plasma samples.
BACKGROUND: Viral load (VL) monitoring is the standard of care in developing country settings for detecting HIV treatment failure. Since 2010 the World Health Organization has recommended a phase-in approach to VL monitoring in resource-limited settings. We conducted a systematic review of the accuracy and precision of HIV VL technologies for treatment monitoring. METHODS AND FINDINGS: A search of Medline and Embase was conducted for studies evaluating the accuracy or reproducibility of commercially available HIV VL assays. 37 studies were included for review including evaluations of the Amplicor Monitor HIV-1 v1.5 (n = 25), Cobas TaqMan v2.0 (n = 11), Abbott RealTime HIV-1 (n = 23), Versant HIV-1 RNA bDNA 3.0 (n = 15), Versant HIV-1 RNA kPCR 1.0 (n = 2), ExaVir Load v3 (n = 2), and NucliSens EasyQ v2.0 (n = 1). All currently available HIV VL assays are of sufficient sensitivity to detect plasma virus levels at a lower detection limit of 1,000 copies/mL. Bias data comparing the Abbott RealTime HIV-1, TaqMan v2.0 to the Amplicor Monitor v1.5 showed a tendency of the Abbott RealTime HIV-1 to under-estimate results while the TaqMan v2.0 overestimated VL counts. Compared to the Amplicor Monitor v1.5, 2-26% and 9-70% of results from the Versant bDNA 3.0 and Abbott RealTime HIV-1 differed by greater than 0.5log10. The average intra and inter-assay variation of the Abbott RealTime HIV-1 were 2.95% (range 2.0-5.1%) and 5.44% (range 1.17-30.00%) across the range of VL counts (2log10-7log10). CONCLUSIONS: This review found that all currently available HIV VL assays are of sufficient sensitivity to detect plasma VL of 1,000 copies/mL as a threshold to initiate investigations of treatment adherence or possible treatment failure. Sources of variability between VL assays include differences in technology platform, plasma input volume, and ability to detect HIV-1 subtypes. Monitoring of individual patients should be performed on the same technology platform to ensure appropriate interpretation of changes in VL. Prospero registration # CD42013003603
Systematic review of the use of dried blood spots for monitoring HIV viral load and for early infant diagnosis.
BACKGROUND: Dried blood spots (DBS) have been used as alternative specimens to plasma to increase access to HIV viral load (VL) monitoring and early infant diagnosis (EID) in remote settings. We systematically reviewed evidence on the performance of DBS compared to plasma for VL monitoring and EID. METHODS AND FINDINGS: Thirteen peer reviewed HIV VL publications and five HIV EID papers were included. Depending on the technology and the viral load distribution in the study population, the percentage of DBS samples that are within 0.5 log of VL in plasma ranged from 52-100%. Because the input sample volume is much smaller in a blood spot, there is a risk of false negatives with DBS. Sensitivity of DBS VL was found to be 78-100% compared to plasma at VL below 1000 copies/ml, but this increased to 100% at a threshold of 5000 copies/ml. Unlike a plasma VL test which measures only cell free HIV RNA, a DBS VL also measures proviral DNA as well as cell-associated RNA, potentially leading to false positive results when using DBS. The systematic review showed that specificity was close to 100% at DBS VL above 5000 copies/ml, and this threshold would be the most reliable for predicting true virologic failure using DBS. For early infant diagnosis, DBS has a sensitivity of 100% compared to fresh whole blood or plasma in all studies. CONCLUSIONS: Although limited data are available for EID, DBS offer a highly sensitive and specific sampling strategy to make viral load monitoring and early infant diagnosis more accessible in remote settings. A standardized approach for sampling, storing, and processing DBS samples would be essential to allow successful implementation. TRIAL REGISTRATION: PROSPERO Registration #: CRD42013003621
- …