388 research outputs found

    The Cognitive Symptom Checklist-Work in cancer patients is related with work functioning, fatigue and depressive symptoms: a validation study

    Get PDF
    The study objectives are to translate the 21-item Cognitive Symptom Checklist-Work (CSC-W21) to Dutch (CSC-W DV) and to validate the CSC-W DV in working cancer patients. The CSC-W21 was cross-culturally translated and adapted to a Dutch version. In this 19-item version, the dichotomous response option was changed to an ordinal five-point scale. A validation study of the CSC-W DV was conducted among cancer patients who had returned to work during or following cancer treatment. Internal consistency (Cronbach's alpha), structural validity (exploratory factor analysis) and construct validity (hypothesis testing) were evaluated. In a cohort of 364 cancer patients, 341 (94 %) completed the CSC-W DV (aged 50.6 +/- 8.6 years, 60 % women). Exploratory factor analysis revealed two subscales 'working memory' and 'executive function'. The internal consistency of the total scale and subscales was high (Cronbach's alpha = 0.93-0.95). Hypothesis testing showed that self-reported cognitive limitations at work were related to work functioning (P <0.001), fatigue (P = 0.001) and depressive symptoms (P <0.001), but not to self-rated health (P = 0.14). The CSC-W DV showed high internal consistency and reasonable construct validity for measuring work-specific cognitive symptoms in cancer patients. The CSC-W DV was associated in expected ways with work functioning, fatigue and depressive symptoms. It is important to enhance knowledge about cognitive symptoms at work in cancer patients, to guide and support cancer patients as good as possible when they are back at work and to improve their work functioning over time

    Atomic excitation during recollision-free ultrafast multi-electron tunnel ionization

    Full text link
    Modern intense ultrafast pulsed lasers generate an electric field of sufficient strength to permit tunnel ionization of the valence electrons in atoms. This process is usually treated as a rapid succession of isolated events, in which the states of the remaining electrons are neglected. Such electronic interactions are predicted to be weak, the exception being recollision excitation and ionization caused by linearly-polarized radiation. In contrast, it has recently been suggested that intense field ionization may be accompanied by a two-stage `shake-up' reaction. Here we report a unique combination of experimental techniques that enables us to accurately measure the tunnel ionization probability for argon exposed to 50 femtosecond laser pulses. Most significantly for the current study, this measurement is independent of the optical focal geometry, equivalent to a homogenous electric field. Furthermore, circularly-polarized radiation negates recollision. The present measurements indicate that tunnel ionization results in simultaneous excitation of one or more remaining electrons through shake-up. From an atomic physics standpoint, it may be possible to induce ionization from specific states, and will influence the development of coherent attosecond XUV radiation sources. Such pulses have vital scientific and economic potential in areas such as high-resolution imaging of in-vivo cells and nanoscale XUV lithography.Comment: 17 pages, 4 figures, original format as accepted by Nature Physic

    The SPEAR Instrument and On-Orbit Performance

    Full text link
    The SPEAR (or 'FIMS') instrumentation has been used to conduct the first large-scale spectral mapping of diffuse cosmic far ultraviolet (FUV, 900-1750 AA) emission, including important diagnostics of interstellar hot (10^4 K - 10^6 K) and photoionized plasmas, H_2, and dust scattered starlight. The instrumentation's performance has allowed for the unprecedented detection of astrophysical diffuse far UV emission lines. A spectral resolution of 550 and an imaging resolution of 5' is achieved on-orbit in the Short (900 - 1175 AA) and Long (1335 - 1750 AA) bandpass channels within their respective 7.4 deg x 4.3' and 4.0 deg x 4.6' fields of view. We describe the SPEAR imaging spectrographs, their performance, and the nature and handling of their data

    Musculoskeletal symptoms of the upper extremities and the neck: A cross-sectional study on prevalence and symptom-predicting factors at visual display terminal (VDT) workstations

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this study was to determine the prevalence and the predictors of musculoskeletal symptoms in the upper extremities and neck at visual display terminal (VDT) workstations.</p> <p>Methods</p> <p>In a cross-sectional study 1,065 employees working at VDT > 1 h/d completed a standardised questionnaire. Workstation conditions were documented in a standardised checklist, and a subgroup of 82 employees underwent a physical examination.</p> <p>Results</p> <p>Using the Nordic Questionnaire, the 12-month prevalence of symptoms of the neck, shoulder region, hand/wrist, or elbow/lower arm was 55%, 38%, 21%, and 15% respectively. The duration of VDT work had a significant impact on the frequency of neck symptoms in employees performing such work > 6 h/d.</p> <p>Conclusion</p> <p>With regard to musculoskeletal symptoms of the upper extremities, preventive measures at VDT workstations should be focused on neck and shoulder symptoms (e.g. ergonomic measures, breaks to avoid sitting over long periods).</p

    The Spectroscopy of Plasma Evolution from Astrophysical Radiation Mission

    Full text link
    The Spectroscopy of Plasma Evolution from Astrophysical Radiation (or the Far-ultraviolet Imaging Spectrograph) instruments, flown aboard the STSAT-1 satellite mission, have provided the first large-area spectral mapping of the cosmic far ultraviolet (FUV, lambda 900-1750 Ang) background. We observe diffuse radiation from hot (10^4 to 10^6 K) and ionized plasmas, molecular hydrogen, and dust scattered starlight. These data provide for the unprecedented detection and discovery of spectral emission from a variety of interstellar environments, including the general medium, molecular clouds, supernova remnants, and super-bubbles. We describe the mission and its data, present an overview of the diffuse FUV sky's appearance and spectrum, and introduce the scientific findings detailed later in this volume

    Precision of the PET activity range during irradiation with <sup>10</sup>C, <sup>11</sup>C, and <sup>12</sup>C beams

    Get PDF
    Objective. Beams of stable ions have been a well-established tool for radiotherapy for many decades. In the case of ion beam therapy with stable 12C ions, the positron emitters 10,11C are produced via projectile and target fragmentation, and their decays enable visualization of the beam via positron emission tomography (PET). However, the PET activity peak matches the Bragg peak only roughly and PET counting statistics is low. These issues can be mitigated by using a short-lived positron emitter as a therapeutic beam. Approach. An experiment studying the precision of the measurement of ranges of positron-emitting carbon isotopes by means of PET has been performed at the FRS fragment-separator facility of GSI Helmholtzzentrum fĂŒr Schwerionenforschung GmbH, Germany. The PET scanner used in the experiment is a dual-panel version of a Siemens Biograph mCT PET scanner. Main results. High-quality in-beam PET images and activity distributions have been measured from the in-flight produced positron emitting isotopes 11C and 10C implanted into homogeneous PMMA phantoms. Taking advantage of the high statistics obtained in this experiment, we investigated the time evolution of the uncertainty of the range determined by means of PET during the course of irradiation, and show that the uncertainty improves with the inverse square root of the number of PET counts. The uncertainty is thus fully determined by the PET counting statistics. During the delivery of 1.6 × 107 ions in 4 spills for a total duration of 19.2 s, the PET activity range uncertainty for 10C, 11C and 12C is 0.04 mm, 0.7 mm and 1.3 mm, respectively. The gain in precision related to the PET counting statistics is thus much larger when going from 11C to 10C than when going from 12C to 11C. The much better precision for 10C is due to its much shorter half-life, which, contrary to the case of 11C, also enables to include the in-spill data in the image formation. Significance. Our results can be used to estimate the contribution from PET counting statistics to the precision of range determination in a particular carbon therapy situation, taking into account the irradiation scenario, the required dose and the PET scanner characteristics.</p

    Are Pain Intensity and Pain Related Fear Related to Functional Capacity Evaluation Performances of Patients with Chronic Low Back Pain?

    Get PDF
    Introduction: Pain related fear and pain intensity have been identified as factors negatively influencing Functional Capacity Evaluation (FCE) performances in patients with CLBP. Conflicting results have been reported in the literature. The objective of this study was to analyze the relationships between pain intensity and pain-related fear on the one hand, and performances during an FCE on the other hand in two samples of patients with chronic low back pain (CLBP). Methods: Two cross sectional observation studies were performed with two samples of patients with CLBP (study 1: n = 79; study 2: n = 58). Pain related fears were operationally defined as the score on the Tampa Scale of Kinesiophobia in study 1, and the Fear Avoidance Beliefs Questionnaire (FABQ) in study 2. Pain intensity was measured with a Numeric Rating Scale in both studies. Avoidance behavior observed during FCE was in both studies operationally defined as the unwillingness to engage in high intensity performance levels of three different functional activities: high intensity lifting, prolonged standing in a forward bend position, and fast repetitive bending at the waist. Results: A total of 25 correlations between pain and pain related fear, and performance variables were calculated, out of which 7 were significant (p < 0.05). The strength of these significant correlations ranged from r = −0.23 to r = −0.50. Multivariate linear regression analyses revealed non-significant relationships in most instances. Pain and pain related fear contributed little if any to these models. Conclusions: The relation between pain and pain related fear and FCE performance is weak or non-existent in patients with CLBP
    • 

    corecore