1,547 research outputs found

    Consistency conditions for regulatory analysis of financial institutions: a comparison of frontier efficiency methods

    Get PDF
    We propose a set of consistency conditions that frontier efficiency measures should meet to be most useful for regulatory analysis or other purposes. The efficiency estimates should be consistent in their efficiency levels, rankings, and identification of best and worst firms, consistent over time and with competitive conditions in the market, and consistent with standard nonfrontier measures of performance. We provide evidence on these conditions by evaluating and comparing efficiency estimates on U.S. bank efficiency from variants of all four of the major approaches -- DEA, SFA, TFA, and DFA -- and find mixed results.Financial institutions ; Bank supervision

    An Investigation of the Maximum Specimen Thickness for Differential Phase Contrast Lorentz Microscopy

    Get PDF
    Examination of magnetic domain structure in the transmission electron microscope is generally confined to very thin foils, where the specimen approximates to a pure phase object, and is achieved by the long established methods of Fresnel or Foucault contrast Lorentz microscopy, or by differential phase contrast (DPC) imaging in a scanning transmission electron microscope (STEM). If no quantitative interpretation of the image is required then magnetic contrast can be observed from thicker foils, and in this paper we describe an attempt to determine experimentally the range of foil thickness over which this is possible. To this end we have examined electropolished foils of single crystal Incalloy using an extended VG HB501 STEM to produce both DPC and Fresnel contrast images of the same area. The foil thickness at points along the domain walls was measured from the change in the Lorentz deflection angle as the STEM probe was moved across the domain wall, and this led to an estimate of ~ 700nm for the limiting thickness at which domain contrast was still visible in the DPC images. This value is obviously influenced by a number of factors, including the degree of inelastic scattering and the saturation magnetisation of the material, but it is sufficiently high that there might exist a range of thickness over which both transmission and scanning electron microscopes could be used to study the domain structure in the same areas of specimen

    Remarks on the tight-binding model of graphene

    Get PDF
    We address a simple but fundamental issue arising in the study of graphene, as well as of other systems that have a crystalline structure with more than one atom per unit cell. For these systems, the choice of the tight-binding basis is not unique. For monolayer graphene two bases are widely used in the literature. While the expectation values of operators describing physical quantities should be independent of basis, the form of the operators may depend on the basis, especially in the presence of disorder or of an applied magnetic field. Using the inappropriate form of certain operators may lead to erroneous physical predictions. We discuss the two bases used to describe monolayer graphene, as well as the form of the most commonly used operators in the two bases. We repeat our analysis for the case of bilayer graphene.Comment: 15 pages, 4 figure

    On the correlation between fragility and stretching in glassforming liquids

    Full text link
    We study the pressure and temperature dependences of the dielectric relaxation of two molecular glassforming liquids, dibutyl phtalate and m-toluidine. We focus on two characteristics of the slowing down of relaxation, the fragility associated with the temperature dependence and the stretching characterizing the relaxation function. We combine our data with data from the literature to revisit the proposed correlation between these two quantities. We do this in light of constraints that we suggest to put on the search for empirical correlations among properties of glassformers. In particular, argue that a meaningful correlation is to be looked for between stretching and isochoric fragility, as both seem to be constant under isochronic conditions and thereby reflect the intrinsic effect of temperature

    Altered hippocampal function in major depression despite intact structure and resting perfusion

    Get PDF
    Background: Hippocampal volume reductions in major depression have been frequently reported. However, evidence for functional abnormalities in the same region in depression has been less clear. We investigated hippocampal function in depression using functional magnetic resonance imaging (fMRI) and neuropsychological tasks tapping spatial memory function, with complementing measures of hippocampal volume and resting blood flow to aid interpretation. Method: A total of 20 patients with major depressive disorder (MDD) and a matched group of 20 healthy individuals participated. Participants underwent multimodal magnetic resonance imaging (MRI): fMRI during a spatial memory task, and structural MRI and resting blood flow measurements of the hippocampal region using arterial spin labelling. An offline battery of neuropsychological tests, including several measures of spatial memory, was also completed. Results: The fMRI analysis showed significant group differences in bilateral anterior regions of the hippocampus. While control participants showed task-dependent differences in blood oxygen level-dependent (BOLD) signal, depressed patients did not. No group differences were detected with regard to hippocampal volume or resting blood flow. Patients showed reduced performance in several offline neuropsychological measures. All group differences were independent of differences in hippocampal volume and hippocampal blood flow. Conclusions: Functional abnormalities of the hippocampus can be observed in patients with MDD even when the volume and resting perfusion in the same region appear normal. This suggests that changes in hippocampal function can be observed independently of structural abnormalities of the hippocampus in depression

    Dynamic heterogeneities in attractive colloids

    Full text link
    We study the formation of a colloidal gel by means of Molecular Dynamics simulations of a model for colloidal suspensions. A slowing down with gel-like features is observed at low temperatures and low volume fractions, due to the formation of persistent structures. We show that at low volume fraction the dynamic susceptibility, which describes dynamic heterogeneities, exhibits a large plateau, dominated by clusters of long living bonds. At higher volume fraction, where the effect of the crowding of the particles starts to be present, it crosses over towards a regime characterized by a peak. We introduce a suitable mean cluster size of clusters of monomers connected by "persistent" bonds which well describes the dynamic susceptibility.Comment: 4 pages, 4 figure

    A study of the significance of photoparoxysmal responses and spontaneous epileptiform discharges in the EEG in childhood epilepsy

    Get PDF
    Aim: In clinical practice, there is a prevailing notion that photosensitivity mostly occurs in children with epilepsy (CWE) with idiopathic generalized epilepsy. We investigated the distribution of epilepsy types and etiology in photosensitive children and the associations with specific clinical and electroencephalogram (EEG) variables. Methods: In this retrospective cohort study, clinical data were acquired from all children that showed photosensitivity during systematic intermittent photic stimulation (IPS), over a 10-year interval at a tertiary level Children\u27s Hospital, Winnipeg. Patient demographics, EEG findings, and clinical data and symptoms during IPS were abstracted. Classification of diagnoses using the International League Against Epilepsy (ILAE) 2017 guidelines was done by an expert panel. Results: Seventy-eight photosensitive children were identified. Forty (51.3%) had generalized epilepsy (idiopathic: 27, structural: 2, other: 11) compared with 19 (24.4%) focal (idiopathic: 1, structural: 2, other: 16), 8 (10.3%) combined focal and generalized (structural: 4, other: 4), and 11 (14.1%) unknown epilepsy (other: 11); (χ2 (3) = 32.1, p = .000). Self-sustaining or outlasting photoparoxysmal responses (PPRs) occurred in association with all epilepsy types; however, the EEGs of focal CWE without treatment comprised almost solely of PPRs which outlasted the stimulus (8/10), in contrast to only 8/17 of focal CWE with treatment and to 13/26 of generalized epilepsy without treatment. Most frequency intervals in individual patients were less under treatment: a decrease in standardized photosensitivity range (SPR) was seen in 5 CWE, an increase in 2, and no change in 1 during treatment. Both CWE with focal and generalized epilepsy showed abnormal activity on EEG during hyperventilation (40% vs 65.7%). Thirteen out of 14 CWE with clinical signs during IPS had independent spontaneous epileptiform discharges (SEDs) in the EEG recording. Conclusion: Photosensitivity occurs in all types of epilepsy rather than in idiopathic generalized epilepsy alone. Surprisingly, there is a tendency for focal epilepsy to be associated with self-sustaining PPRs, especially when no treatment is used. Treatment tends to make the PPR more self-limiting and decrease the SPR. There is a tendency that clinical signs during IPS occur in EEGs in individuals with SEDs
    corecore