9 research outputs found

    Avaliação da reprodutibilidade intra e interexaminador no registro da relação cêntrica, após um programa de calibração

    Get PDF
    Centric relation (CR) has been considered a maxillomandibular position of choice for some dental and prosthetic procedures. Although regarded as a fully reproducible relation, there is great controversy about its clinical use and recording technique, especially in patients with signs and symptoms of temporomandibular disorders (TMD). This study aimed at evaluating the effectiveness of a training program on intra- and interexaminer agreement when determining the clinical record of the CR position. Forty individuals constituted the sample, divided into symptomatic (TMD) and asymptomatic groups. Three previously calibrated examiners performed the initial assessment and the second evaluation after 30 days in a blind design, using Dawsons bilateral manipulation technique with and without an anterior stop. The amount of frontal and sagittal deviations in relation to intercuspal position, the presence of pain and discomfort during manipulation, and the first occlusal contact in CR were analyzed. Kendall and Kappa tests with a 5% level of significance were used to determine agreement. Values for both intra- and interexaminer agreement were deemed good. The best results were obtained for frontal deviations and assessment of pain (or absence of it) during manipulation. Sagittal deviations showed the lowest agreement in both examinations. The authors concluded that a calibration program could be effective for intra- and interexaminer agreement when recording centric relation. However, caution is recommended when analyzing some isolated items.Na tentativa de estabelecer uma posição maxilomandibular reprodutível em pacientes sem dentes suportes posteriores ou portadores de oclusão instável, o conceito de relação cêntrica (RC) foi introduzido. Apesar de ser utilizada como uma posição de referência, existe uma considerável divergência de opiniões sobre a sua reprodutibilidade. Este estudo procurou avaliar se os métodos de treinamento profissional são efetivos na análise e obtenção de RC. Para isso utilizou-se uma amostra de 40 indivíduos, divididos em 20 assintomáticos e 20 portadores de disfunções da ATM. Os indivíduos foram avaliados por 3 examinadores, previamente calibrados. Foram realizados 2 exames: inicial e final (30 dias após o inicial), possibilitando dessa forma, análise da concordância interexaminadores, assim como intra- examinadores. Posteriormente, os resultados foram submetidos à análise estatística, utilizando-se os testes de concordância de Kendall e de Kappa. Os resultados foram considerados bons, sendo os melhores obtidos para a análise do desvio frontal e relato de dor (ou ausência) durante a manipulação. Os autores concluíram que os programas de calibração podem ser efetivos para análise da RC. No entanto, cautela é recomendada quando da análise de alguns itens isolados

    Centric relation registration: intra- and interexaminer agreement after a calibration program Avaliação da reprodutibilidade intra e interexaminador no registro da relação cêntrica, após um programa de calibração

    No full text
    Centric relation (CR) has been considered a maxillomandibular position of choice for some dental and prosthetic procedures. Although regarded as a fully reproducible relation, there is great controversy about its clinical use and recording technique, especially in patients with signs and symptoms of temporomandibular disorders (TMD). This study aimed at evaluating the effectiveness of a training program on intra- and interexaminer agreement when determining the clinical record of the CR position. Forty individuals constituted the sample, divided into symptomatic (TMD) and asymptomatic groups. Three previously calibrated examiners performed the initial assessment and the second evaluation after 30 days in a blind design, using Dawson’s bilateral manipulation technique with and without an anterior stop. The amount of frontal and sagittal deviations in relation to intercuspal position, the presence of pain and discomfort during manipulation, and the first occlusal contact in CR were analyzed. Kendall and Kappa tests with a 5% level of significance were used to determine agreement. Values for both intra- and interexaminer agreement were deemed good. The best results were obtained for frontal deviations and assessment of pain (or absence of it) during manipulation. Sagittal deviations showed the lowest agreement in both examinations. The authors concluded that a calibration program could be effective for intra- and interexaminer agreement when recording centric relation. However, caution is recommended when analyzing some isolated items.<br>Na tentativa de estabelecer uma posição maxilomandibular reprodutível em pacientes sem dentes suportes posteriores ou portadores de oclusão instável, o conceito de relação cêntrica (RC) foi introduzido. Apesar de ser utilizada como uma posição de referência, existe uma considerável divergência de opiniões sobre a sua reprodutibilidade. Este estudo procurou avaliar se os métodos de treinamento profissional são efetivos na análise e obtenção de RC. Para isso utilizou-se uma amostra de 40 indivíduos, divididos em 20 assintomáticos e 20 portadores de disfunções da ATM. Os indivíduos foram avaliados por 3 examinadores, previamente calibrados. Foram realizados 2 exames: inicial e final (30 dias após o inicial), possibilitando dessa forma, análise da concordância interexaminadores, assim como intra- examinadores. Posteriormente, os resultados foram submetidos à análise estatística, utilizando-se os testes de concordância de Kendall e de Kappa. Os resultados foram considerados bons, sendo os melhores obtidos para a análise do desvio frontal e relato de dor (ou ausência) durante a manipulação. Os autores concluíram que os programas de calibração podem ser efetivos para análise da RC. No entanto, cautela é recomendada quando da análise de alguns itens isolados

    Effects of pre‐operative isolation on postoperative pulmonary complications after elective surgery: an international prospective cohort study

    No full text
    We aimed to determine the impact of pre-operative isolation on postoperative pulmonary complications after elective surgery during the global SARS-CoV-2 pandemic. We performed an international prospective cohort study including patients undergoing elective surgery in October 2020. Isolation was defined as the period before surgery during which patients did not leave their house or receive visitors from outside their household. The primary outcome was postoperative pulmonary complications, adjusted in multivariable models for measured confounders. Pre-defined sub-group analyses were performed for the primary outcome. A total of 96,454 patients from 114 countries were included and overall, 26,948 (27.9%) patients isolated before surgery. Postoperative pulmonary complications were recorded in 1947 (2.0%) patients of which 227 (11.7%) were associated with SARS-CoV-2 infection. Patients who isolated pre-operatively were older, had more respiratory comorbidities and were more commonly from areas of high SARS-CoV-2 incidence and high-income countries. Although the overall rates of postoperative pulmonary complications were similar in those that isolated and those that did not (2.1% vs 2.0%, respectively), isolation was associated with higher rates of postoperative pulmonary complications after adjustment (adjusted OR 1.20, 95%CI 1.05-1.36, p = 0.005). Sensitivity analyses revealed no further differences when patients were categorised by: pre-operative testing; use of COVID-19-free pathways; or community SARS-CoV-2 prevalence. The rate of postoperative pulmonary complications increased with periods of isolation longer than 3 days, with an OR (95%CI) at 4-7 days or &gt;= 8 days of 1.25 (1.04-1.48), p = 0.015 and 1.31 (1.11-1.55), p = 0.001, respectively. Isolation before elective surgery might be associated with a small but clinically important increased risk of postoperative pulmonary complications. Longer periods of isolation showed no reduction in the risk of postoperative pulmonary complications. These findings have significant implications for global provision of elective surgical care

    ILC Reference Design Report Volume 1 - Executive Summary

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization

    ILC Reference Design Report Volume 4 - Detectors

    No full text
    This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics

    ILC Reference Design Report Volume 3 - Accelerator

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC

    International Linear Collider Reference Design Report Volume 2: PHYSICS AT THE ILC

    No full text
    This article reviews the physics case for the ILC. Baseline running at 500 GeV as well as possible upgrades and options are discussed. The opportunities on Standard Model physics, Higgs physics, Supersymmetry and alternative theories beyond the Standard Model are described.This article reviews the physics case for the ILC. Baseline running at 500 GeV as well as possible upgrades and options are discussed. The opportunities on Standard Model physics, Higgs physics, Supersymmetry and alternative theories beyond the Standard Model are described
    corecore