10 research outputs found

    The Future of Neonatal Skull Suture Detection

    Get PDF
    Instrumental birth is common practice, but without properly determining the position of the fetus prior to placement, trauma to both mother and baby can occur. Currently, internal vaginal examination is the easiest method to determine fetus position, but is challenging as it requires tactile feedback to determine anatomical landmarks. To assist clinicians with this task, we have designed a novel sensor glove that can detect changes in the surface that indicate anatomical structures of the neonatal head, thus allowing the user to determine the position of the fetus. However, we still need to determine the utility and usability of this device. In this work in progress, we present the pilot study and explore improvements based on the findings from the study to refine both general and ecological validity aspects of the study

    Preventing stillbirth from obstructed labor: A sensorized, low-cost device to train in safer operative birth

    Get PDF
    BACKGROUND: 98% of stillbirths occur in low- and middle- income countries. Obstructed labor is a common cause for both neonatal and maternal mortality, with a lack of skilled birth attendants one of the main reasons for the reduction in operative vaginal birth, especially in low- and middle- income countries. We introduce a low cost, sensorized, wearable device for digital vaginal examination to facilitate accurate assessment of fetal position and force applied to the fetal head, to aid training in safe operative vaginal birth. METHODS: The device consists of flexible pressure/force sensors mounted onto the fingertips of a surgical glove. Phantoms of the neonatal head were developed to replicate sutures. An Obstetrician tested the device on the phantoms by performing a mock vaginal examination at full dilatation. Data was recorded and signals interpreted. Software was developed so that the glove can be used with a simple smartphone app. A patient and public involvement panel was consulted on the glove design and functionality. RESULTS: The sensors achieved a 20 Newton force range and a 0.1 Newton sensitivity, leading to 100% accuracy in detecting fetal sutures, including when different degrees of molding or caput were present. They also detected sutures and force applied with a second sterile surgical glove on top. The software developed allowed a force threshold to be set, alerting the clinician when excessive force is applied. Patient and public involvement panels welcomed the device with great enthusiasm. Feedback indicated that women would accept, and prefer, clinicians to use the device if it could improve safety and reduce the number of vaginal examinations required. CONCLUSION: Under phantom conditions to simulate the fetal head in labor, the novel sensorized glove can accurately determine fetal sutures and provide real-time force readings, to support safer clinical training and practice in operative birth. The glove is low cost (approximately 1 USD). Software is being developed so fetal position and force readings can be displayed on a mobile phone. Although substantial steps in clinical translation are required, the glove has the potential to support efforts to reduce the number of stillbirths and maternal deaths secondary to obstructed labor in low- and -middle income countries

    Flexible triboelectric nanogenerators using transparent copper nanowires electrodes: Energy harvesting, sensing human activities and material recognition

    Get PDF
    Triboelectric nanogenerators (TENGs) have emerged as a promising green technology to efficiently harvest otherwise wasted mechanical energy from environment and human activities. However, cost-effective and reliable TENGs require rational integration..

    A Triboelectric Nanocomposite for Sterile Sensing, Energy Harvesting, and Haptic Diagnostics in Interventional Procedures from Surgical Gloves

    Get PDF
    Advanced interfacial engineering has the potential to enable the successful realization of three features that are particularly important for a variety of healthcare applications: wettability control, antimicrobial activity to reduce infection risks, and sensing of physiological parameters. Here, a sprayable multifunctional triboelectric coating is exploited as a nontoxic, ultrathin tactile sensor that can be integrated directly on the fingertips of surgical gloves. The coating is based on a polymer blend mixed with zinc oxide (ZnO) nanoparticles, which enables antifouling and antibacterial properties. Additionally, the nanocomposite is superhydrophobic (self-cleaning) and is not cytotoxic. The coating is also triboelectric and can be applied directly onto surgical gloves with printed electrodes. The sensorized gloves so obtained enable mechanical energy harvesting, force sensing, and detection of materials stiffness changes directly from fingertip, which may complement proprioceptive feedback for clinicians. Just as importantly, the sensors also work with a second glove on top offering better reassurance regarding sterility in interventional procedures. As a case study of clinical use for stiffness detection, the sensors demonstrate successful detection of pig anal sphincter injury ex vivo. This may lead to improving the accuracy of diagnosing obstetric anal sphincter injury, resulting in prompt repair, fewer complications, and improved quality of life

    A stretchable, self-healing and semi-transparent nanogenerator for energy harvesting and sensing

    Get PDF
    Triboelectric nanogenerators (TENGs) with an ability to harvest mechanical energy from natural and human activities, have shown tremendous potential to realise self-powered electronic devices and sensors. However, in order for optimum utilization of biomechanical energy, TENGs need to have body or tissue mimicking properties without compromising performance. Herein, a new hydrogel based all-soft, self-healing and stretchable TENG is introduced which exhibits outstanding power generation capability surpassing existing competitors. This unique TENG is realized by using gold nanoparticles doped semi-transparent hydrogel as an electrode and Ecoflex as the triboelectric layer which integrates multifunctional properties including rapid self-healing in < 2 min, 900% stretchability, high conductivity, transparency and excellent biocompatibility with human dermal fibroblasts. The use of a gel electrode with both ionic and electronic conductivities underlines the importance of gold nanoparticles in enhancing the performance of soft TENGs. A 5 cm^{2} device exhibits a prodigious power density of 1680 mWm^{−2} with an energy conversion efficiency of ≈ 26%, which is the highest achieved so far in contemporary hydrogel based TENGs. The moldable components allow easy fabrication of devices with tunable shapes and sizes that conforms to the human body and can power multiple electrical devices directly from body movements thus opening up possibilities for next generation self-powered wearable or implanted devices

    A Sensorised Surgical Glove to Analyze Forces During Neurosurgery

    Get PDF
    BACKGROUND: Measuring intraoperative forces in real time can provide feedback mechanisms to improve patient safety and surgical training. Previous force monitoring has been achieved through the development of specialized and adapted instruments or use designs that are incompatible with neurosurgical workflow. OBJECTIVE: To design a universal sensorised surgical glove to detect intraoperative forces, applicable to any surgical procedure, and any surgical instrument in either hand. METHODS: We created a sensorised surgical glove that was calibrated across 0 to 10 N. A laboratory experiment demonstrated that the sensorised glove was able to determine instrument-tissue forces. Six expert and 6 novice neurosurgeons completed a validated grape dissection task 20 times consecutively wearing the sensorised glove. The primary outcome was median and maximum force (N). RESULTS: The sensorised glove was able to determine instrument-tissue forces reliably. The average force applied by experts (2.14 N) was significantly lower than the average force exerted by novices (7.15 N) (P = .002). The maximum force applied by experts (6.32 N) was also significantly lower than the maximum force exerted by novices (9.80 N) (P = .004). The sensorised surgical glove’s introduction to operative workflow was feasible and did not impede on task performance. CONCLUSION: We demonstrate a novel and scalable technique to detect forces during neurosurgery. Force analysis can provide real-time data to optimize intraoperative tissue forces, reduce the risk of tissue injury, and provide objective metrics for training and assessment

    A Deep Learning Approach to Classify Surgical Skill in Microsurgery Using Force Data from a Novel Sensorised Surgical Glove

    Get PDF
    Microsurgery serves as the foundation for numerous operative procedures. Given its highly technical nature, the assessment of surgical skill becomes an essential component of clinical practice and microsurgery education. The interaction forces between surgical tools and tissues play a pivotal role in surgical success, making them a valuable indicator of surgical skill. In this study, we employ six distinct deep learning architectures (LSTM, GRU, Bi-LSTM, CLDNN, TCN, Transformer) specifically designed for the classification of surgical skill levels. We use force data obtained from a novel sensorized surgical glove utilized during a microsurgical task. To enhance the performance of our models, we propose six data augmentation techniques. The proposed frameworks are accompanied by a comprehensive analysis, both quantitative and qualitative, including experiments conducted with two cross-validation schemes and interpretable visualizations of the network’s decision-making process. Our experimental results show that CLDNN and TCN are the top-performing models, achieving impressive accuracy rates of 96.16% and 97.45%, respectively. This not only underscores the effectiveness of our proposed architectures, but also serves as compelling evidence that the force data obtained through the sensorzsed surgical glove contains valuable information regarding surgical skill

    A synthetic model simulator for intracranial aneurysm clipping: validation of the UpSurgeOn AneurysmBox

    Get PDF
    Background and objectives: In recent decades, the rise of endovascular management of aneurysms has led to a significant decline in operative training for surgical aneurysm clipping. Simulation has the potential to bridge this gap and benchtop synthetic simulators aim to combine the best of both anatomical realism and haptic feedback. The aim of this study was to validate a synthetic benchtop simulator for aneurysm clipping (AneurysmBox, UpSurgeOn). Methods: Expert and novice surgeons from multiple neurosurgical centres were asked to clip a terminal internal carotid artery aneurysm using the AneurysmBox. Face and content validity were evaluated using Likert scales by asking experts to complete a post-task questionnaire. Construct validity was evaluated by comparing expert and novice performance using the modified Objective Structured Assessment of Technical Skills (mOSATS), developing a curriculum-derived assessment of Specific Technical Skills (STS), and measuring the forces exerted using a force-sensitive glove. Results: Ten experts and eighteen novices completed the task. Most experts agreed that the brain looked realistic (8/10), but far fewer agreed that the brain felt realistic (2/10). Half the expert participants (5/10) agreed that the aneurysm clip application task was realistic. When compared to novices, experts had a significantly higher median mOSATS (27 vs. 14.5; p < 0.01) and STS score (18 vs. 9; p < 0.01); the STS score was strongly correlated with the previously validated mOSATS score (p < 0.01). Overall, there was a trend towards experts exerting a lower median force than novices, however, these differences were not statistically significant (3.8 N vs. 4.0 N; p = 0.77). Suggested improvements for the model included reduced stiffness and the addition of cerebrospinal fluid (CSF) and arachnoid mater. Conclusion: At present, the AneurysmBox has equivocal face and content validity, and future versions may benefit from materials that allow for improved haptic feedback. Nonetheless, it has good construct validity, suggesting it is a promising adjunct to training

    Datasheet1_Preventing stillbirth from obstructed labor: A sensorized, low-cost device to train in safer operative birth.docx

    No full text
    Background98% of stillbirths occur in low- and middle- income countries. Obstructed labor is a common cause for both neonatal and maternal mortality, with a lack of skilled birth attendants one of the main reasons for the reduction in operative vaginal birth, especially in low- and middle- income countries. We introduce a low cost, sensorized, wearable device for digital vaginal examination to facilitate accurate assessment of fetal position and force applied to the fetal head, to aid training in safe operative vaginal birth.MethodsThe device consists of flexible pressure/force sensors mounted onto the fingertips of a surgical glove. Phantoms of the neonatal head were developed to replicate sutures. An Obstetrician tested the device on the phantoms by performing a mock vaginal examination at full dilatation. Data was recorded and signals interpreted. Software was developed so that the glove can be used with a simple smartphone app. A patient and public involvement panel was consulted on the glove design and functionality.ResultsThe sensors achieved a 20 Newton force range and a 0.1 Newton sensitivity, leading to 100% accuracy in detecting fetal sutures, including when different degrees of molding or caput were present. They also detected sutures and force applied with a second sterile surgical glove on top. The software developed allowed a force threshold to be set, alerting the clinician when excessive force is applied. Patient and public involvement panels welcomed the device with great enthusiasm. Feedback indicated that women would accept, and prefer, clinicians to use the device if it could improve safety and reduce the number of vaginal examinations required.ConclusionUnder phantom conditions to simulate the fetal head in labor, the novel sensorized glove can accurately determine fetal sutures and provide real-time force readings, to support safer clinical training and practice in operative birth. The glove is low cost (approximately 1 USD). Software is being developed so fetal position and force readings can be displayed on a mobile phone. Although substantial steps in clinical translation are required, the glove has the potential to support efforts to reduce the number of stillbirths and maternal deaths secondary to obstructed labor in low- and -middle income countries.</p

    Analysis of Outcomes in Ischemic vs Nonischemic Cardiomyopathy in Patients With Atrial Fibrillation A Report From the GARFIELD-AF Registry

    No full text
    IMPORTANCE Congestive heart failure (CHF) is commonly associated with nonvalvular atrial fibrillation (AF), and their combination may affect treatment strategies and outcomes