8 research outputs found

    The ability of synovitis to predict structural damage in rheumatoid arthritis: A comparative study between clinical examination and ultrasound

    Get PDF
    Objectives: To evaluate synovitis (clinical vs ultrasound (US)) to predict structural progression in rheumatoid arthritis (RA). Methods: Patients with RA. Study design: Prospective, 2-year follow-up. Data collected: Synovitis (32 joints (2 wrists, 10 metacarpophalangeal, 10 proximal interphalangeal, 10 metatarsophalangeal)) at baseline and after 4 months of therapy by clinical, US grey scale (GS-US) and power doppler (PD-US); x-rays at baseline and at year 2. Analysis: Measures of association (OR) were tested between structural deterioration and the presence of baseline synovitis, or its persistence, after 4 months of therapy using generalised estimating equation analysis. Results: Structural deterioration was observed in 9% of the 1888 evaluated joints in 59 patients. Baseline synovitis increased the risk of structural progression: OR=2.01 (1.36-2.98) p<0.001 versus 1.61 (1.06-2.45) p=0.026 versus 1.75 (1.18-2.58) p=0.005 for the clinical versus US-GS versus US-PD evaluation, respectively. In the joints with normal baseline examination (clinical or US), an increased probability for structural progression in the presence of synovitis for the other modality was also observed (OR=2.16 (1.16-4.02) p=0.015 and 3.50 (1.77-6.95) p<0.001 for US-GS and US-PD and 2.79 (1.35-5.76) p=0.002) for clinical examination. Persistent (vs disappearance) synovitis after 4 months of therapy was also predictive of subsequent structural progression. Conclusions: This study confi rms the validity of synovitis for predicting subsequent structural deterioration irrespective of the modality of examination of joints, but also suggests that both clinical and ultrasonographic examinations may be relevant to optimally evaluate the risk of subsequent structural deterioration

    A slope variation in the Period-Luminosity relation for short period SMC Cepheids

    Get PDF
    We present the Period-Luminosity relations from 290 Cepheids towards the LMC and 590 Cepheids towards the SMC. The two data sets were obtained using the two wide field CCD cameras of the EROS 2 microlensing survey. We observe a significant slope change of the period-luminosity relation for the SMC fundamental mode Cepheids with periods shorter than 2 days. Many possible experimental biases have been investigated, but none can account for this effect. We also observe different spatial distributions for SMC Cepheids with different ages i.e. periods. Different possible explanations of the slope change are discussed

    The impact of space experiments on our knowledge of the physics of the universe

    No full text
    corecore