47 research outputs found
Adapting a practical EPR dosimetry protocol to measure output factors in small fields with alanine.
PURPOSE
Modern radiotherapy techniques often deliver small radiation fields. In this work, a practical Electron Paramagnetic Resonance (EPR) dosimetry protocol is adapted and applied to measure output factors (OF) in small fields of a 6 MV radiotherapy system. Correction factors and uncertainties are presented and OFs are compared to the values obtained by following TRS-483 using an ionization chamber (IC).
METHODS
Irradiations were performed at 10 cm depth inside a water phantom positioned at 90 cm source to surface distance with a 6 MV flattening filter free photon beam of a Halcyon radiotherapy system. OFs for different nominal field sizes (1 × 1, 2 × 2, 3 × 3, 4 × 4, normalized to 10 × 10 cm2 ) were determined with a PinPoint 3D (PTW 31022) IC following TRS-483 as well as with alanine pellets with a diameter of 4 mm and a height of 2.4 mm. EPR readout was performed with a benchtop X-band spectrometer. Correction factors due to volume averaging and due to positional uncertainties were derived from 2D film measurements.
RESULTS
OFs obtained from both dosimeter types agreed within 0.7% after applying corrections for the volume averaging effect. For the used alanine pellets, volume averaging correction factors of 1.030(2) for the 1 × 1 cm2 field and <1.002 for the larger field sizes were determined. The correction factor for positional uncertainties of 1 mm was in the order of 1.018 for the 1 × 1 cm2 field. Combined relative standard uncertainties uc for the OFs resulting from alanine measurements were estimated to be below 1.5% for all field sizes. For IC measurements, uc was estimated to be below 1.0%.
CONCLUSIONS
A practical EPR dosimetry protocol is adaptable for precisely measuring OFs in small fields down to 1 × 1 cm2 . It is recommended to consider the effect of positional uncertainties for field sizes <2 × 2 cm2
10101 Abstracts Collection -- Computational Foundations of Social Choice
From March 7 to March 12, 2010, the Dagstuhl Seminar 10101
``Computational Foundations of Social Choice \u27\u27 was held in Schloss Dagstuhl~--~Leibniz Center for Informatics.
During the seminar, several participants presented their current
research, and ongoing work and open problems were discussed. Abstracts of
the presentations given during the seminar as well as abstracts of seminar results and ideas are put together in this paper. The first section
describes the seminar topics and goals in general.
Links to extended abstracts or full papers are provided, if available
10101 Executive Summary -- Computational Foundations of Social Choice
This seminar addressed some of the key issues in computational social choice, a novel interdisciplinary field of study at the interface of social choice theory and computer science. Computational social choice is concerned with the application of computational techniques to the study of social choice mechanisms, such as voting rules and fair division protocols, as well as with the integration of social choice paradigms into computing. The seminar brought together many of the most active researchers in the field and focussed the research community currently forming around these important and exciting topics
Long term results of postoperative Intensity-Modulated Radiation Therapy (IMRT) in the treatment of Squamous Cell Carcinoma (SCC) located in the oropharynx or oral cavity
Background: To report our long-term results with postoperative intensity-modulated radiation therapy (IMRT) in patients suffering from squamous-cell carcinoma (SCC) of the oral cavity or oropharynx. Methods: Seventy five patients were retrospectively analyzed. Median age was 58 years and 84 % were male. 76 % of the primaries were located in the oropharynx. Surgery resulted in negative margins (R0) in 64 % of the patients while 36 % suffered from positive margins (R1). Postoperative stages were as follows: stage1:4 %, stage2:9 %, stage3:17 %, stage4a:69 % with positive nodes in 84 %. Perineural invasion (Pn+) and extracapsular extension (ECE) were present in 7 % and 29 %, respectively. All patients received IMRT using the step-and-shoot approach with a simultaneously integrated boost (SIB) in 84 %. Concurrent systemic therapy was applied to 53 patients, mainly cisplatin weekly. Results: Median follow-up was 55 months (5–150). 13 patients showed locoregional failures (4 isolated local, 4 isolated neck, 5 combined) transferring into 5-year-LRC rates of 85 %. Number of positive lymph nodes (n > 2) and presence of ECE were significantly associated with decreased LRC in univariate analysis, but only the number of nodes remained significant in multivariate analysis. Overall treatment failures occurred in 20 patients (9 locoregional only, 7 distant only, 4 combined), transferring into 3-and 5-year-FFTF rates of 77 % and 75 %, respectively. The 3-and 5-year-OS rates were 80 % and 72 %, respectively. High clinical stage, high N stage, number of positive nodes (n > 2), ECE and Pn1 were significantly associated with worse FFTF and OS in univariate analysis, but only number of nodes remained significant for FFTF in multivariate analysis. Maximum acute toxicity was grade 3 in 64 % and grade 4 in 1 %, mainly hematological or mucositis/dysphagia. Maximum late toxicity was grade 3 in 23 % of the patients, mainly long-term tube feeding dependency. Conclusion: Postoperative IMRT achieved excellent LRC and good OS with acceptable acute and low late toxicity rates. The number of positive nodes (n > 2) was a strong prognostic factor for all endpoints in univariate and the only significant factor for LRC and FFTF in multivariate analysis. Patients with feeding tubes due to postoperative complications had an increased risk for long-term feeding tube dependency
Intensity modulated or fractionated stereotactic reirradiation in patients with recurrent nasopharyngeal cancer
<p>Abstract</p> <p>Purpose</p> <p>To report our experience with intensity-modulated or stereotactic reirradiation in patients suffering from recurrent nasopharyngeal carcinoma</p> <p>Patients and Methods</p> <p>The records of 17 patients with recurrent nasopharygeal carcinoma treated by intensity-modulated (n = 14) or stereotactic (n = 3) reirradiation in our institution were reviewed. Median age was 53 years and most patients (n = 14) were male. The majority of tumors showed undifferentiated histology (n = 14) and infiltration of intracranial structures (n = 12). Simultaneous systemic therapy was applied in 8 patients. Initial treatment covered the gross tumor volume with a median dose of 66 Gy (50-72 Gy) and the cervical nodal regions with a median dose of 56 Gy (50-60 Gy). Reirradiation was confined to the local relapse region with a median dose of 50.4 Gy (36-64Gy), resulting in a median cumulative dose of 112 Gy (91-134 Gy). The median time interval between initial and subsequent treatment was 52 months (6-132).</p> <p>Results</p> <p>The median follow up for the entire cohort was 20 months and 31 months for survivors (10-84). Five patients (29%) developed isolated local recurrences and three patients (18%) suffered from isolated nodal recurrences. The actuarial 1- and 2-year rates of local/locoregional control were 76%/59% and 69%/52%, respectively. Six patients developed distant metastasis during the follow up period. The median actuarial overall survival for the entire cohort was 23 months, transferring into 1-, 2-, and 3-year overall survival rates of 82%, 44% and 37%. Univariate subset analyses showed significantly increased overall survival and local control for patients with less advanced rT stage, retreatment doses > 50 Gy, concurrent systemic treatment and complete response. Severe late toxicity (Grad III) attributable to reirradiation occurred in five patients (29%), particularly as hearing loss, alterations of taste/smell, cranial neuropathy, trismus and xerostomia.</p> <p>Conclusion</p> <p>Reirradiation with intensity-modulated or stereotactic techniques in recurrent nasopharyngeal carcinoma is feasible and yields encouraging results in terms of local control and overall survival in patients with acceptable toxicity in patients with less advanced recurrences. However, the achievable outcome is limited in patients with involvement of intracranial structures, emphasising the need for close monitoring after primary therapy.</p
Recommended from our members
Biases in comparative analyses of extinction risk: mind the gap
. Comparative analyses are used to address the key question of what makes a species more prone to extinction by exploring the links between vulnerability and intrinsic species’ traits and ⁄ or extrin- sic factors. This approach requires comprehensive species data but information is rarely available for all species of interest. As a result comparative analyses often rely on subsets of relatively few species that are assumed to be representative samples of the overall studied group.
2. Our study challenges this assumption and quantifies the taxonomic, spatial, and data type biases associated with the quantity of data available for 5415 mammalian species using the freely available life-history database PanTHERIA.
3. Moreover, we explore how existing biases influence results of comparative analyses of extinc- tion risk by using subsets of data that attempt to correct for detected biases. In particular, we focus on links between four species’ traits commonly linked to vulnerability (distribution range area, adult body mass, population density and gestation length) and conduct univariate and multivari- ate analyses to understand how biases affect model predictions.
4. Our results show important biases in data availability with c.22% of mammals completely lack- ing data. Missing data, which appear to be not missing at random, occur frequently in all traits (14–99% of cases missing). Data availability is explained by intrinsic traits, with larger mammals occupying bigger range areas being the best studied. Importantly, we find that existing biases affect the results of comparative analyses by overestimating the risk of extinction and changing which traits are identified as important predictors.
5. Our results raise concerns over our ability to draw general conclusions regarding what makes a species more prone to extinction. Missing data represent a prevalent problem in comparative anal- yses, and unfortunately, because data are not missing at random, conventional approaches to fill data gaps, are not valid or present important challenges. These results show the importance of making appropriate inferences from comparative analyses by focusing on the subset of species for which data are available. Ultimately, addressing the data bias problem requires greater investment in data collection and dissemination, as well as the development of methodological approaches to effectively correct existing biases.Peer reviewe
Intensity modulated radiotherapy (IMRT) with concurrent chemotherapy as definitive treatment of locally advanced esophageal cancer
Background: To report our experience with increased dose intensity-modulated radiation and concurrent systemic chemotherapy as definitive treatment of locally advanced esophageal cancer. Patients and methods: We analyzed 27 consecutive patients with histologically proven esophageal cancer, who were treated with increased-dose IMRT as part of their definitive therapy. The majority of patients had T3/4 and/or N1 disease (93%). Squamous cell carcinoma was the dominating histology (81%). IMRT was delivered in step-and-shoot technique in all patients using an integrated boost concept. The boost volume was covered with total doses of 56-60 Gy (single dose 2-2.14 Gy), while regional nodal regions received 50.4 Gy (single dose 1.8 Gy) in 28 fractions. Concurrent systemic therapy was scheduled in all patients and administered in 26 (96%). 17 patients received additional adjuvant systemic therapy. Loco-regional control, progression-free and overall survival as well as acute and late toxicities were retrospectively analyzed. In addition, quality of life was prospectively assessed according to the EORTC QLQs (QLQ-OG25, QLQ-H&N35 and QLQ-C30). Results: Radiotherapy was completed as planned in all but one patient (96%), and 21 patients received more than 80% of the planned concurrent systemic therapy. We observed ten locoregional failures, transferring into actuarial 1-, 2- and 3-year-locoregional control rates of 77%, 65% and 48%. Seven patients developed distant metastases, mainly to the lung (71%). The actuarial 1-, 2- and 3-year-disease free survival rates were 58%, 48% and 36%, and overall survival rates were 82%, 61% and 56%. The concept was well tolerated, both in the clinical objective examination and also according to the subjective answers to the QLQ questionnaire. 14 patients (52%) suffered from at least one acute CTC grade 3/4 toxicity, mostly hematological side effects or dysphagia. Severe late toxicities were reported in 6 patients (22%), mostly esophageal strictures and ulcerations. Severe side effects to skin, lung and heart were rare. Conclusion: IMRT with concurrent systemic therapy in the definitive treatment of esophageal cancer using an integrated boost concept with doses up to 60 Gy is feasible and yields good results with acceptable acute and late overall toxicity and low side effects to skin, lung and heart
Biological in-vivo measurement of dose distribution in patients' lymphocytes by gamma-H2AX immunofluorescence staining: 3D conformal- vs. step-and-shoot IMRT of the prostate gland
<p>Abstract</p> <p>Background</p> <p>Different radiation-techniques in treating local staged prostate cancer differ in their dose- distribution. Physical phantom measurements indicate that for 3D, less healthy tissue is exposed to a relatively higher dose compared to SSIMRT. The purpose is to substantiate a dose distribution in lymphocytes <it>in-vivo </it>and to discuss the possibility of comparing it to the physical model of total body dose distribution.</p> <p>Methods</p> <p>For each technique (3D and SSIMRT), blood was taken from 20 patients before and 10 min after their first fraction of radiotherapy. The isolated leukocytes were fixed 2 hours after radiation. DNA double-strand breaks (DSB) in lymphocytes' nuclei were stained immunocytochemically using the gamma-H2AX protein. Gamma-H2AX foci inside each nucleus were counted in 300 irradiated as well as 50 non-irradiated lymphocytes per patient. In addition, lymphocytes of 5 volunteer subjects were irradiated externally at different doses and processed under same conditions as the patients' lymphocytes in order to generate a calibration-line. This calibration-line assigns dose-value to mean number of gamma-H2AX foci/ nucleus. So the dose distributions in patients' lymphocytes were determined regarding to the gamma-H2AX foci distribution. With this information a cumulative dose-lymphocyte-histogram (DLH) was generated. Visualized distribution of gamma-H2AX foci, correspondingly dose per nucleus, was compared to the technical dose-volume-histogram (DVH), related to the whole body-volume.</p> <p>Results</p> <p>Measured <it>in-vivo </it>(DLH) and according to the physical treatment-planning (DVH), more lymphocytes resulted with low-dose exposure (< 20% of the applied dose) and significantly fewer lymphocytes with middle-dose exposure (30%-60%) during Step-and-Shoot-IMRT, compared to conventional 3D conformal radiotherapy. The high-dose exposure (> 80%) was equal in both radiation techniques. The mean number of gamma-H2AX foci per lymphocyte was 0.49 (3D) and 0.47 (SSIMRT) without significant difference.</p> <p>Conclusions</p> <p><it>In-vivo </it>measurement of the dose distribution within patients' lymphocytes can be performed by detecting gamma-H2AX foci. In case of 3D and SSIMRT, the results of this method correlate with the physical calculated total body dose-distribution, but cannot be interpreted unrestrictedly due to the blood circulation. One possible application of the present method could be in radiation-protection for <it>in-vivo </it>dose estimation after accidental exposure to radiation.</p
The influence of a magnetic field on photon beam radiotherapy in a normal human TK6 lymphoblastoid cell line
Background: The implementation of magnetic resonance imaging (MRI) guided radiotherapy (RT) continues to increase. Very limited in-vitro data on the interaction of ionizing radiation and magnetic fields (MF) have been published. In these experiments we focused on the radiation response in a MF of the TK6 human lymphoblastoid cells which are known to be highly radiosensitive due to efficient radiation-induced apoptosis.
Methods: Clonogenicity was determined 12–14 days after irradiation with 1–4 Gy 6 MV photons with or without a 1.0 Tesla MF. Furthermore, alterations in cell cycle distribution and rates of radiation induced apoptosis (FACS analysis of cells with sub-G1 DNA content) were analyzed.
Results: Clonogenic survival showed an exponential dose-dependence, and the radiation sensitivity parameter (α = 1.57/Gy) was in accordance with earlier reports. Upon comparing the clonogenic survival between the two groups, identical results within error bars were obtained. The survival fractions at 2 Gy were 9% (without MF) and 8.5% (with MF), respectively.
Conclusion: A 1.0 Tesla MF does not affect the clonogenicity of TK6 cells irradiated with 1–4 Gy 6MV photons. This supports the use of MRI guided RT, however ongoing research on the interaction of MF and radiotherapy is warranted