13 research outputs found

    Esthetic comparison between ceramic systems on darkened substrate

    Get PDF
    Purpose: The objective of this work was to evaluate visually the possible influence of a darkened substrate on the aesthetic result of crowns with infiltrations of lithium disilicate or zirconia. Methodology: The design was observational, transversal and descriptive. For the experiment, a patient with total crowns at 11 and 21 was selected, where one of the two elements should be darkened. A crown of lithium disilicate was made on the substrate without color change. For the darkened element, a crown of lithium disilicate and one of zirconia were created, creating two clinical situations. Without knowing which material was used, the evaluators answered a questionnaire that compared the aesthetic result of the lithium disilicate or zirconia crowns with the lithium disilicate crown on the normal substrate, as well as the two clinical situations. A total of 20 dental surgeons participated as evaluators. The evaluators judged the restorations to be excellent, acceptable or unacceptable, and afterwards a descriptive analysis of the evaluations was performed. Results: The results showed that there was aesthetic difference between the restorations of lithium disilicate and zirconia, and the lithium disilicate could not block the color of the substrate, even though an opaque ingot (MO) was used. Conclusion: It was concluded that in cases of darkened substrate, an infrastructure with sufficient opacity, such as zirconia, with visually perceptible and unacceptable differences, if a translucent material such as lithium disilicate is used

    Reforço da resina acrílica para restaurações provisórias utilizando diferentes formatos e posições do fio ortodôntico

    Get PDF
    Objetivos. Avaliar a influência do forma do fio ortodôntico e sua posição vertical no reforço de uma resina acrílica utilizada para próteses parciais fixas provisórias.Método. Foram confeccionadas 70 barras (25 x 3 x 3 mm) utilizando resina acrílica à base de polimetilmetacrilato com diferentes reforços (n = 10). Dois diferentes formatos da secção transversal do fio foram avaliados: circular (C) e retangular (R). Três posições verticais do fio também foram avaliadas: superior (S), mediana (M), inferior (I). Espécimes do grupo controle foram avaliados sem reforço. As diferentes condições experimentais foram avaliadas em teste de resistência à flexão por 3 pontos em máquina universal de ensaios. Os dados foram analisados utilizando a análise de variância ANOVA (1-fator) seguido pelo teste de Tukey (α = 0,05).Resultados. Os valores médios de resistência à flexão e desvio padrão foram:  RI = 171±15a; CI = 125±15b; RM = 117±11bc; RS = 108±13cd; CM = 99±7d; controle = 90±4d; e CS = 89±10d.Conclusão. A utilização de fio ortodôntico retangular na posição inferior do material apresentou a melhor condição de reforço da resina acrílica para prótese parcial fixa provisória

    Impression in fixed prosthesis: fabrication of impression cap

    Get PDF
    O objetivo do artigo foi descrever a técnica de confecção de uma moldeira individual para moldagem de preparo total para coroa, também conhecida como casquete de moldagem, além de discutir fatores e princípios envolvidos no tema. Na presente técnica, é obtido um modelo de gesso da região do preparo e um alívio em cera é realizado em suas paredes axiais. Após a aplicação de um isolante, o casquete é confeccionado utilizando pó e líquido de resina acrílica ativada quimicamente indicada para confecção de restaurações provisórias. A resina acrílica é aplicada na região cervical utilizando um pincel, e em seguida, o restante do preparo é preenchido. Após finalizado o corpo do casquete, a área de retenção é criada (chapéu do casquete), a face vestibular é demarcada, e realizado acabamento e polimento.The aim of this manuscript was to describe the technique for manufacturing an individual impression cap for tooth preparation impression on the processing of full-contour prosthetic restorations, besides discussing factors and principles involved on this topic. In the present technique, first, a stone partial model is obtained, considering the region to be restored, and then a wax relief is created on its axial region to grant space for the impression material. After applying a resin isolator, the impression cap is obtained by incremental technique using a brush with chemically activated acrylic resin. Finally, a retention portion is created on the top of the obtained cap, the vestibular face is marked and then finishing and polishing are executed

    Propriedades ópticas relacionadas à estética dental

    Get PDF
    A restauração de um dente mantendo sua naturalidade sob quaisquer circunstânciasé uma tarefa difícil, devido às complexas características ópticas que influenciamneste processo. Fenômenos ópticos como a cor do dente, sua translucidez,opacidade, opalescência, fluorescência, fonte luminosa ambiente e seus relativosefeitos de metamerismo, têm um papel importantíssimo na maneira como percebemosum dente e, consequentemente, o processo de mimetização realizado duranteo tratamento restaurador. O sucesso nos resultados estéticos depende da integraçãode alguns fatores que se tornam críticos para tal: conhecimento de princípiosbásicos sobre a percepção das cores, percepção inerente a cada indivíduo, fontede luz utilizada durante a avaliação da cor, características estruturais de superfíciedos dentes e dos materiais restauradores utilizados, registro destas informações ea comunicação com o laboratório quando forem realizadas restaurações indiretas.Neste contexto, tendo como objetivo final o desenvolvimento de uma percepçãomais apurada das características estéticas da dentição natural, este artigo buscourevisar a literatura com o intuito de auxiliar o clínico a adquirir o entendimento deprincípios relacionados à cor, luz e as propriedades ópticas que são inerentes aosdentes,cerâmicas e resinas compostas

    Masking ability of different ceramic systems over a darkened substrate: case report

    No full text
    This clinical report describes the masking ability of IPS e.max ceramic (lithium disilicate glass-ceramic and polycrystalline zirconia) used over darkened (metallic post) and natural-colored backgrounds. Initially, medium-opacity lithium disilicate glass-ceramic framework (IPS e.max Press MO) was used over both backgrounds. It was observed that at the minimum thickness recommended by the manufacturer, the medium-opacity lithium disilicate glass-ceramic framework did not provide sufficient masking ability over the darkened background (metallic post). Then, because of its inadequate masking ability, the lithium disilicate glass-ceramic framework over the metallic post was replaced with polycrystalline zirconia (IPS e.max ZirCAD). It was concluded that using polycrystalline zirconia resulted in better masking ability and superior final aesthetic appearance over a darkened background

    Tightening techniques for the retaining screws of universal abutment

    No full text
    Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control &#8211; 32 Ncm torque; H20 &#8211; holding 32 Ncm torque for 20 s; R &#8211; 32 Ncm torque, repeated after 10 min (retorque); and H20+R &#8211; combining the two tightening techniques. Titanium and coated screws were also evaluated. Result Statistical analysis showed higher maintained torque for titanium screws (p<0.001). The H20+R technique showed the highest maintained torque (p=0.003), but the H20 technique&#8217;s maintained torque was similar. Conclusion Titanium screws associating the two tightening techniques can improve maintained torque

    Tightening techniques for the retaining screws of universal abutment

    No full text
    Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm torque, repeated after 10 min (retorque); and H20+R – combining the two tightening techniques. Titanium and coated screws were also evaluated. Result Statistical analysis showed higher maintained torque for titanium screws (p<0.001). The H20+R technique showed the highest maintained torque (p=0.003), but the H20 technique’s maintained torque was similar. Conclusion Titanium screws associating the two tightening techniques can improve maintained torque
    corecore