2,094 research outputs found

    HCOOCH3 as a probe of temperature and structure of Orion-KL

    Full text link
    We studied the O-bearing molecule HCOOCH3 to characterize the physical conditions of the different molecular source components in Orion-KL. We identify 28 methyl formate emission peaks throughout the 50" field of observations. The two strongest peaks are in the Compact Ridge (MF1) and in the SouthWest of the Hot Core (MF2). Spectral confusion is still prevailing as half of the expected transitions are blended over the region. Assuming that the transitions are thermalized, we derive the temperature at the five main emission peaks. At the MF1 position we find a temperature of 80K in a 1.8"x0.8" beam size and 120K on a larger scale (3.6" x2.2"), suggesting an external source of heating, whereas the temperature is about 130K at the MF2 position on both scales. Transitions of HCOOCH3 in vt=1 are detected as well and the good agreement of the positions on the rotational diagrams between the vt=0 and the vt=1 transitions suggests a similar temperature. The velocity of the gas is between 7.5 and 8.0km/s depending on the positions and column density peaks vary from 1.6x10^16 to 1.6x10^17cm^-2. A second velocity component is observed around 9-10 km/s in a North-South structure stretching from the Compact Ridge up to the BN object; this component is warmer at the MF1 peak. The two other C2H4O2 isomers are not detected and the derived upper limit for the column density is <3x10^14cm^-2 for glycolaldehyde and <2x10^15cm^-2 for acetic acid. From the 223GHz continuum map, we identify several dust clumps with associated gas masses in the range 0.8 to 5.8Msun. Assuming that the HCOOCH3 is spatially distributed as the dust, we find relative abundances of HCOOCH3 in the range <0.1x10^-8 to 5.2x10^-8. We suggest a relation between the methyl formate distribution and shocks as traced by 2.12 mum H2 emission.Comment: Accepted for publication in A&

    Role of Quantum Confinement in Luminescence Efficiency of Group IV Nanostructures

    Full text link
    Experimental results obtained previously for the photoluminescence efficiency (PLeff_{eff}) of Ge quantum dots (QDs) are theoretically studied. A log\log-log\log plot of PLeff_{eff} versus QD diameter (DD) resulted in an identical slope for each Ge QD sample only when EG(D2+D)1E_{G}\sim (D^2+D)^{-1}. We identified that above DD\approx 6.2 nm: EGD1E_{G}\sim D^{-1} due to a changing effective mass (EM), while below DD\approx 4.6 nm: EGD2E_{G}\sim D^{-2} due to electron/ hole confinement. We propose that as the QD size is initially reduced, the EM is reduced, which increases the Bohr radius and interface scattering until eventually pure quantum confinement effects dominate at small DD

    Local tetragonal distortion in La_{0.7}Sr_{0.3}MnO_3 strained thin films probed by x-ray absorption spectroscopy

    Full text link
    We report on an angular resolved X-ray Absorption Spectroscopy study of La0.7Sr0.3MnO3La_{0.7}Sr_{0.3}MnO_{3} thin films epitaxially grown by pulsed laser deposition on slightly mismatched substrates which induce tensile or compressive strains. XANES spectra give evidence of tetragonal distortion within the MnO6MnO_{6} octahedra, with opposite directions for tensile and compressive strains. Quantitative analysis has been done and a model of tetragonal distortion reflecting the strain has been established. EXAFS data collected in plane for tensile substrate confirm the change in the MnOMn-O average bond distance and the increase of MnMnMn-Mn length matching with the enlargement of the cell parameter. From these results we conclude that there is no significant change in the MnOMnMn-O-Mn angle. Our observations conflict with the scenarios which this angle is the main driving parameter in the sensitivity of manganite films properties to external strains and suggest that the distortion within the octahedra plays a key role in the modification of the transport and magnetic properties.Comment: 8 pages, 6 figure

    Dissipative Structures in Supersonic Turbulence

    Full text link
    We show that density-weighted moments of the dissipation rate, ϵl\epsilon_l, averaged over a scale ll, in supersonic turbulence can be successfully explained by the She and L\'ev\^eque model [Phys. Rev. Lett. {\bf 72}, 336 (1994)]. A general method is developed to measure the two parameters of the model, γ\gamma and dd, based directly on their physical interpretations as the scaling exponent of the dissipation rate in the most intermittent structures (γ\gamma) and the dimension of the structures (dd). We find that the best-fit parameters (γ=0.71\gamma=0.71 and d=1.90d=1.90) derived from the ϵl\epsilon_l scalings in a simulation of supersonic turbulence at Mach 6 agree with their direct measurements, confirming the validity of the model in supersonic turbulence.Comment: 4 pages, 3 figures, accepted by Phys. Rev. Let

    Experimental study of Taylor's hypothesis in a turbulent soap film

    Get PDF
    An experimental study of Taylor's hypothesis in a quasi-two-dimensional turbulent soap film is presented. A two probe laser Doppler velocimeter enables a non-intrusive simultaneous measurement of the velocity at spatially separated points. The breakdown of Taylor's hypothesis is quantified using the cross correlation between two points displaced in both space and time; correlation is better than 90% for scales less than the integral scale. A quantitative study of the decorrelation beyond the integral scale is presented, including an analysis of the failure of Taylor's hypothesis using techniques from predictability studies of turbulent flows. Our results are compared with similar studies of 3D turbulence.Comment: 27 pages, + 19 figure

    Application of large area SiPMs for the readout of a plastic scintillator based timing detector

    Full text link
    In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided in light of the results

    Application of large area SiPMs for the readout of a plastic scintillator based timing detector

    Full text link
    In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided in light of the results

    Ten-year follow-up of a total knee prosthesis combining multi-radius, ultra-congruency, posterior-stabilization and mobile-bearing insert shows long-lasting clinically relevant improvements in pain, stiffness, function and stability.

    Get PDF
    There is a paucity of data available on total knee prostheses combining dual-radius, ultra-congruency, posterior-stabilization and mobile-bearing insert. This prospective cohort study aimed to assess the clinical evolution of the FIRST &lt;sup&gt;®&lt;/sup&gt; prosthesis (Symbios Orthopédie, Yverdon, CH), the earliest prosthesis with this particular design. It was hypothesized that the primary outcomes, evaluating pain, stiffness, function and stability, would improve following arthroplasty and remain improved during the follow-up period of 10 years. All patients programmed for a total knee arthroplasty using a FIRST &lt;sup&gt;®&lt;/sup&gt; prosthesis at our university hospital between 2006 and 2008 were invited to participate. Study knees were evaluated pre-operatively as well as one, five and ten years post-operatively. Patients filled out questionnaires at each evaluation point and had a radiographic assessment at the five-year and ten-year follow-ups. Primary outcomes were the total, pain, stiffness and function measures of the Western Ontario and McMaster Universities Osteoarthritis questionnaire (WOMAC) and the knee and function measures of the Knee Society Score (KSS). Friedman and Wilcoxon's rank-sum tests were used to compare measures across time points. Hundred and twenty four prostheses were included (baseline demographics: 69.9 ± 8.3 years old, 28.1 ± 4.3 kg/m &lt;sup&gt;2&lt;/sup&gt; , 54% male) and 68 could be followed during ten years. Five prostheses underwent a revision. All other prostheses lost at follow-up were lost for reasons unrelated to the prosthesis. All primary measures reported statistically and clinically significant improvements between baseline and the three follow-up evaluations. Statistically significant improvements at the three follow-up evaluations were also observed for most secondary measures. There was no implant loosening. At ten-year follow-up, radiolucent lines were observed in 2.9% femoral implants and 1.5% tibial implants. The positive results observed in all domains of assessment and the small revision rate demonstrated an effective functioning of the FIRST &lt;sup&gt;®&lt;/sup&gt; prosthesis during the ten-year follow-up period. The results, globally similar to those previously published for other prosthesis designs, encourage the development of assistive methods to select the most appropriate designs on an individual basis. IV, prospective cohort study
    corecore