93 research outputs found

    Water vapour line assignments in the 9250-26 000 cm (-1) frequency range

    Get PDF
    Line parameters for water vapour in natural abundance have recently been determined for the 9250-13 000 cm(-1) region [M.-F. Wrienne, A. Jenouvrier, C. Hermans, A.C. Vandaele, M. Carleer, C. Clerbaux, P.-F. Coheur, R. Colin, S. Fally, M. Bach, J. Quant. Spectrosc. Radiat. Transfer 82 (2003) 99] and the 13 000-26 000 cm(-1) region [P.-F. Coheur, S. Fally, M. Carleer, C. Clerbaux, R. Colin, A. Jenouvrier, M.-F. Wrienne, C. Hermans, A.C. Vandaele, J. Quant. Spectrosc. Radial. Transfer 74 (2002) 493] using a high-resolution Fourier-transform spectrometer with a long-path absorption cell. These spectra are analysed using several techniques including variational line lists and assignments made. In total, over 15 000 lines were assigned to transitions involving more than 150 exited vibrational states of (H2O)-O-16. Twelve new vibrational band origins are determined and estimates for a further 16 are presented. (c) 2005 Elsevier Inc. All rights reserved

    Improved water vapour spectroscopy in the 4174-4300 cm⁻¹ region and its impact on SCIAMACHY HDO/H₂O measurements

    Get PDF
    The relative abundance of the heavy water isotopologue HDO provides a deeper insight into the atmospheric hydrological cycle. The SCanning Imaging Absorption spectroMeter for Atmospheric CartograpHY (SCIAMACHY) allows for global retrievals of the ratio HDO/HO in the 2.3 micron wavelength range. However, the spectroscopy of water lines in this region remains a large source of uncertainty for these retrievals. We therefore evaluate and improve the water spectroscopy in the range 4174–4300 cm⁻¹ and test if this reduces systematic uncertainties in the SCIAMACHY retrievals of HDO/H₂O. We use a laboratory spectrum of water vapour to fit line intensity, air broadening and wavelength shift parameters. The improved spectroscopy is tested on a series of ground-based high resolution FTS spectra as well as on SCIAMACHY retrievals of H2O and the ratio HDO/H₂O. We find that the improved spectroscopy leads to lower residuals in the FTS spectra compared to HITRAN 2008 and Jenouvrier et al. (2007) spectroscopy, and the retrievals become more robust against changes in the retrieval window. For both the FTS and SCIAMACHY measurements, the retrieved total H₂O columns decrease by 2–4% and we find a negative shift of the HDO/H₂O ratio, which for SCIAMACHY is partly compensated by changes in the retrieval setup and calibration software. The updated SCIAMACHY HDO/H₂O product shows somewhat steeper latitudinal and temporal gradients and a steeper Rayleigh distillation curve, strengthening previous conclusions that current isotope-enabled general circulation models underestimate the variability in the near-surface HDO/H₂O ratio

    Diffraction of slow neutrons by holographic SiO_2 nanoparticle-polymer composite gratings

    Full text link
    Diffraction experiments with holographic gratings recorded in SiO2_2 nanoparticle-polymer composites have been carried out with slow neutrons. The influence of parameters such as nanoparticle concentration, grating thickness and grating spacing on the neutron-optical properties of such materials has been tested. Decay of the grating structure along the sample depth due to disturbance of the recording process becomes an issue at grating thicknesses of about 100 microns and larger. This limits the achievable diffraction efficiency for neutrons. As a solution to this problem, the Pendell\"{o}sung interference effect in holographic gratings has been exploited to reach a diffraction efficiency of 83% for very cold neutrons.Comment: 7 pages, 3 figures, submitted to Phys. Rev.

    Circulating adrenomedullin estimates survival and reversibility of organ failure in sepsis: the prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock-1 (AdrenOSS-1) study

    Get PDF
    Background: Adrenomedullin (ADM) regulates vascular tone and endothelial permeability during sepsis. Levels of circulating biologically active ADM (bio-ADM) show an inverse relationship with blood pressure and a direct relationship with vasopressor requirement. In the present prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock 1 (, AdrenOSS-1) study, we assessed relationships between circulating bio-ADM during the initial intensive care unit (ICU) stay and short-term outcome in order to eventually design a biomarker-guided randomized controlled trial. Methods: AdrenOSS-1 was a prospective observational multinational study. The primary outcome was 28-day mortality. Secondary outcomes included organ failure as defined by Sequential Organ Failure Assessment (SOFA) score, organ support with focus on vasopressor/inotropic use, and need for renal replacement therapy. AdrenOSS-1 included 583 patients admitted to the ICU with sepsis or septic shock. Results: Circulating bio-ADM levels were measured upon admission and at day 2. Median bio-ADM concentration upon admission was 80.5 pg/ml [IQR 41.5-148.1 pg/ml]. Initial SOFA score was 7 [IQR 5-10], and 28-day mortality was 22%. We found marked associations between bio-ADM upon admission and 28-day mortality (unadjusted standardized HR 2.3 [CI 1.9-2.9]; adjusted HR 1.6 [CI 1.1-2.5]) and between bio-ADM levels and SOFA score (p < 0.0001). Need of vasopressor/inotrope, renal replacement therapy, and positive fluid balance were more prevalent in patients with a bio-ADM > 70 pg/ml upon admission than in those with bio-ADM ≤ 70 pg/ml. In patients with bio-ADM > 70 pg/ml upon admission, decrease in bio-ADM below 70 pg/ml at day 2 was associated with recovery of organ function at day 7 and better 28-day outcome (9.5% mortality). By contrast, persistently elevated bio-ADM at day 2 was associated with prolonged organ dysfunction and high 28-day mortality (38.1% mortality, HR 4.9, 95% CI 2.5-9.8). Conclusions: AdrenOSS-1 shows that early levels and rapid changes in bio-ADM estimate short-term outcome in sepsis and septic shock. These data are the backbone of the design of the biomarker-guided AdrenOSS-2 trial. Trial registration: ClinicalTrials.gov, NCT02393781. Registered on March 19, 2015

    The 2009 edition of the GEISA spectroscopic database

    Get PDF
    The updated 2009 edition of the spectroscopic database GEISA (Gestionet Etudedes Informations Spectroscopiques Atmospheriques ; Management and Study of Atmospheric Spectroscopic Information) is described in this paper. GEISA is a computer-accessible system comprising three independent sub-databases devoted, respectively, to: line parameters, infrared and ultraviolet/visible absorption cross-sections, microphysical and optical properties of atmospheric aerosols. In this edition, 50 molecules are involved in the line parameters sub-database, including 111 isotopologues, for a total of 3,807,997 entries, in the spectral range from 10-6 to 35,877.031cm-1. GEISA, continuously developed and maintained at LMD (Laboratoirede Meteorologie Dynamique, France) since 1976, is implemented on the IPSL/CNRS(France) ‘‘Ether’’ Products and Services Centre WEB site (http://ether.ipsl.jussieu.fr), where all archived spectroscopic data can be handled through general and user friendly associated managements of software facilities. More than 350 researchers are registered for online use of GEISA

    international linkages value added trade and firm productivity in latin america and the caribbean

    Get PDF
    This chapter addresses the following research questions: (i) Are firms characterized by international linkages more productive than other firms? (ii) Are those belonging to industries more involved in GVCs even more productive? To this end, we combine the World Bank Enterprise Survey dataset with the new OECD-WTO TiVA dataset and present three main empirical exercises: (1) an analysis of productivity premia associated with participation in international trade and presence of inward FDI; (2) a Cobb–Douglas output function expanded to firms' international linkages; (3) a further expanded version of the above relationship including the TiVA-based indicators of value added trade and industry participation and position in the global value chain. Our empirical outcomes confirm the presence of a positive causal relationship between participation in international activities and firm performance in the LAC region. Focusing on four big Latin American countries we show that the actual level of involvement into GVCs matters as well
    corecore