96 research outputs found

    Influence of Image Acquisition on Radiation Dose and Image Quality: Full versus Narrow Phase Window Acquisition Using 320 MDCT

    Get PDF
    Purpose. To compare radiation dose and image quality using predefined narrow phase window versus complete phase window with dose modulation during R-R using 320-row MDCTA. Methods:. 114 patients underwent coronary CTA study using 320-row MDCT scanner. 87 patients with mean age (61 + 13 years), mean BMI (29 + 6), and mean heart rate (HR) (58 + 7 bpm) were imaged at predefined 66–80% R-R interval and then reconstructed at 75% while 27 patients with mean age (63 + 16 years), mean BMI (28 + 5), and mean HR (57 + 7 bpm) were scanned throughout the complete R-R interval with tube current modulation. The effective dose (ED) was calculated from dose length product (DLP) and conversion k (0.014 mSv/mGy/cm). Image quality was assessed using a three-point ordinal scale (1 = excellent, 2 = good, and 3 = nondiagnostic). Results:. Both groups were statistically similar to each other with reference of HR (P = 0.59), BMI (P = 0.17), and tube current mAs (P = 0.68). The median radiation dose was significantly higher in those scanned with complete R-R phase window versus narrow phase window (P < 0.0001). Independently of patient and scan parameters, increased phase window was associated with higher radiation dose (P < 0.001). Image quality was better among those scanned with narrow phase window versus complete phase window (P < 0.0001). Conclusion:. Our study supports that good HR control and predefined narrow window acquisition result in lower radiation dose without compromising diagnostic image quality for coronary disease evaluation

    Elevated Levels of IL-10 and G-CSF Associated with Asymptomatic Malaria in Pregnant Women

    Get PDF
    In sub-Saharan Africa, approximately 30 million pregnant women are at risk of contracting malaria annually. Nearly 36% of healthy pregnant women receiving routine antenatal care tested positive for Plasmodium falciparum HRP-II antigen in Ghana. We tested the hypothesis that asymptomatic HRP II positive pregnant women expressed a unique Th1 and Th2 phenotype that differs from healthy controls. Plasma from healthy (n = 15) and asymptomatic (n = 25) pregnant women were evaluated for 27 biomarkers (IL-1b, IL-1ra, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-10, IL-12, IL-13, IL-15, IL- 17, Eotaxin, bFGF-2, G-CSF, GM-CSF, IFN-γ, IP-10, MCP-1, MIP-1α, MIP-1β, PDGF-bb, RANTES, TNF, and VEGF) associated with Th1 and Th2 cytokine homeostasis. IL-10 and G-CSF levels were elevated in the asymptomatic group when compared with the healthy group (P = .031 and .041, resp.). The median ratios of IL-1β:5, IL-1β:10, IL-1β:G-CSF, IL-1β:Eotaxin, IL-12:G-CSF, IL-15:10, IL-17:G-CSF, IL-17:Eotaxin, TNF:IL-4, TNF:IL-5, and TNF:G-CSF were significantly different among the two groups. Thus, asymptomatic malaria carriage may be linked to circulating levels of IL-10 and G-CSF

    Radiation exposure for coronary artery calcium score at prospective 320 row multi-detector computed tomography

    Get PDF
    Purpose:To date there is extensive data on the radiation dose for assessing coronary artery calcium scores (CACS) with 4-64 row multidetector MDCT. However with the advent of 320 row MDCT, the entire heart can be imaged in one beat and thus potentially reduce the radiation dose. The aim of this study was to evaluate radiation dose for CACS on low-dose prospective EKG-triggered 320 row MDCT.Materials and Methods: Informed consent for this retrospective HIPAA-compliant study was waived and approved by our institution’s institutional review board IRB. One hundred and sixty eight consecutive patients (Male 133 (79%): female 35 (21%), mean body mass index BMI 29±5 and mean heart rate 58± bpm) underwent coronary calcium scoring with prospective gating. The scan parameters were 300 mA, 120 kVp, volume scan length (VSL) 160 mm, gantry rotation 0.350 msec and 320 x 0.5 mm detectors at 320 MDCT. Beta blockers were given to patients in a case heart rate HR &gt; 65 bpm. The effective dose (ED) estimates were calculated for all patients from the dose length product and the conversion factor k (0.014 mSv/mGy/cm) as recommended by current guidelines.Results: The mean SD radiation was 1.89±0.79 mSv. Overall the range varied from 0.28-2.48 mSv. The radiation was significantly less in females as compared to males (2.02±0.73 vs. 1.41±0.87, p&lt;0.0001). No differences were noted whether HR was &lt;60 vs. &gt;=60 bpm (1.87±0.79 vs. 1.77±0.84 mSv, p=0.45). On the other hand a higher radiation was noted among obese individuals as compared to those with BMI&lt;30 (1.84±0.82 vs. 1.91±0.80 mSv, p=0.62).Conclusion: Radiation dose obtained from 320-MDCT is similar to those obtained with 4-64 row MDCT. Further studies are needed to assess the feasibility of further lowering the tube current and tube voltage.------------------------------------------------Cite this article as:Khosa F, Khan A, Shuaib W, Clouse M, Budoff M, Blankstein R, Nasir K. Radiation exposure for coronary artery calcium score at prospective 320 row multi-detector computed tomography. Int J Cancer Ther Oncol 2013; 1(2):01023.DOI: http://dx.doi.org/10.14319/ijcto.0102.

    Tetanus and Diphtheria Seroprotection among Children Younger Than 15 Years in Nigeria, 2018: Who Are the Unprotected Children?

    Get PDF
    Serological surveys provide an objective biological measure of population immunity, and tetanus serological surveys can also assess vaccination coverage. We undertook a national assessment of immunity to tetanus and diphtheria among Nigerian children aged <15 years using stored specimens collected during the 2018 Nigeria HIV/AIDS Indicator and Impact Survey, a national cross-sectional household-based survey. We used a validated multiplex bead assay to test for tetanus and diphtheria toxoid-antibodies. In total, 31,456 specimens were tested. Overall, 70.9% and 84.3% of children aged <15 years had at least minimal seroprotection (≥0.01 IU/mL) against tetanus and diphtheria, respectively. Seroprotection was lowest in the north west and north east zones. Factors associated with increased tetanus seroprotection included living in the southern geopolitical zones, urban residence, and higher wealth quintiles (p < 0.001). Full seroprotection (≥0.1 IU/mL) was the same for tetanus (42.2%) and diphtheria (41.7%), while long-term seroprotection (≥1 IU/mL) was 15.1% for tetanus and 6.0% for diphtheria. Full- and long-term seroprotection were higher in boys compared to girls (p < 0.001). Achieving high infant vaccination coverage by targeting specific geographic areas and socio-economic groups and introducing tetanus and diphtheria booster doses in childhood and adolescence are needed to achieve lifelong protection against tetanus and diphtheria and prevent maternal and neonatal tetanus

    Large Outbreak of Neisseria meningitidis Serogroup C - Nigeria, December 2016-June 2017.

    Get PDF
    On February 16, 2017, the Ministry of Health in Zamfara State, in northwestern Nigeria, notified the Nigeria Centre for Disease Control (NCDC) of an increased number of suspected cerebrospinal meningitis (meningitis) cases reported from four local government areas (LGAs). Meningitis cases were subsequently also reported from Katsina, Kebbi, Niger, and Sokoto states, all of which share borders with Zamfara State, and from Yobe State in northeastern Nigeria. On April 3, 2017, NCDC activated an Emergency Operations Center (EOC) to coordinate rapid development and implementation of a national meningitis emergency outbreak response plan. After the outbreak was reported, surveillance activities for meningitis cases were enhanced, including retrospective searches for previously unreported cases, implementation of intensified new case finding, and strengthened laboratory confirmation. A total of 14,518 suspected meningitis cases were reported for the period December 13, 2016-June 15, 2017. Among 1,339 cases with laboratory testing, 433 (32%) were positive for bacterial pathogens, including 358 (82.7%) confirmed cases of Neisseria meningitidis serogroup C. In response, approximately 2.1 million persons aged 2-29 years were vaccinated with meningococcal serogroup C-containing vaccines in Katsina, Sokoto, Yobe, and Zamfara states during April-May 2017. The outbreak was declared over on June 15, 2017, after high-quality surveillance yielded no evidence of outbreak-linked cases for 2 consecutive weeks. Routine high-quality surveillance, including a strong laboratory system to test specimens from persons with suspected meningitis, is critical to rapidly detect and confirm future outbreaks and inform decisions regarding response vaccination
    corecore