119 research outputs found

    Comment to “A.J. Collings, K. Brown, Reconstruction and physical fit analysis of fragmented skeletal remains using 3D imaging and printing” [Forensic Sci. Int.: Rep. 2 (2020) 100114].

    Get PDF
    The creation of virtual 3D-models of objects of forensic interest and the use of 3D printing gained more and more importance in the forensic field during the last years. Comparing radiological imaging techniques, such as CT technology, with surface scan technology for anthropological studies is a field of research in which we are also actively working. This is the reason why we were particularly interested in this paper. As researchers working in a center in which the application of 3D technology including Computed Tomography (CT), 3D Surface-Scanning (3DSS) and 3D printing is integrated in daily casework, we feel committed to answer to this study, because we are surprised by the chosen study design and we cannot agree with the obtained conclusion

    Bipolar distribution of deep-sea benthic foraminifera

    Get PDF
    Abstrac

    Impact of thoracoabdominal imaging on diagnosis and management in patients with suspected infective endocarditis.

    Get PDF
    Embolic events (EEs) are a common complication of infective endocarditis (IE) and their presence can impact diagnosis and modify the therapeutic plan. The present study aimed to describe the role of thoracoabdominal imaging, either thoracoabdominal-pelvic Computed Tomography or <sup>18</sup> F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography, on diagnosis and management of patients with suspected IE. This study was conducted at a university hospital, from January 2014 to June 2022. EEs and IE were defined according to modified Duke criteria. Among 966 episodes with suspected IE and thoracoabdominal imaging, 528 (55%) patients were asymptomatic. At least one EE was found in 205 (21%) episodes. Based on thoracoabdominal imaging findings, the diagnosis was reclassified from rejected to possible or from possible to definite IE in 6 (1%) and 10 (1%) episodes, respectively. Among the 413 patients with IE, at least one EE was found on thoracoabdominal imaging in 143 (35%) episodes. Together with the presence of left-side valvular vegetation >10 mm, the results of thoracoabdominal imaging established a surgical indication (prevention of embolism) in 15 (4%) episodes, 7 of which were asymptomatic. Thoracoabdominal imaging performed in asymptomatic patients with suspected IE improved the diagnosis in only a small proportion of patients. Thoracoabdominal imaging led to a new surgical indication (in association with left-side valvular vegetation >10 mm) in only a small percentage of patients

    High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS

    Get PDF
    Detailed investigations of the limits of a new negative-tone near-UV resist (IBM SU-8) have been performed. SU-8 is an epoxy-based resist designed specifically for ultrathick, high-aspect-ratio MEMS-type applications. We have demonstrated that with single-layer coatings, thicknesses of more than 500 km can be achieved reproducibly. Thicker resist layers can be made by applying multiple coatings, and we have achieved exposures in 1200 IJ-m thick, double-coated SU-8 resist layers. We have found that the aspect ratio for near-UV (400 nm) exposed and developed structures can be greater than 18 and remains constant in the thickness range between 80 and 1200 IJ-m. Vertical sidewall profiles result in good dimensional control over the entire resist thickness. To our knowledge, this is the highest aspect ratio reported for near-UV exposures and the given range of resist thicknesses. These results will open up new possibilities for low-cost LIGA-type processes for MEMS applications. The application potential of SU-8 is demonstrated by several examples of devices and structures fabricated by electroplating and photoplastic techniques. The latter is especially interesting as SU-8 has attractive mechanical properties

    The association of spinal osteoarthritis with lumbar lordosis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Careful review of published evidence has led to the postulate that the degree of lumbar lordosis may possibly influence the development and progression of spinal osteoarthritis, just as misalignment does in other joints. Spinal degeneration can ensue from the asymmetrical distribution of loads. The resultant lesions lead to a domino- like breakdown of the normal morphology, degenerative instability and deviation from the correct configuration. The aim of this study is to investigate whether a relationship exists between the sagittal alignment of the lumbar spine, as it is expressed by lordosis, and the presence of radiographic osteoarthritis.</p> <p>Methods</p> <p>112 female subjects, aged 40-72 years, were examined in the Outpatients Department of the Orthopedics' Clinic, University Hospital of Heraklion, Crete. Lumbar radiographs were examined on two separate occasions, independently, by two of the authors for the presence of osteoarthritis. Lordosis was measured from the top of L<sub>1 </sub>to the bottom of L<sub>5 </sub>as well as from the top of L<sub>1 </sub>to the top of S<sub>1</sub>. Furthermore, the angle between the bottom of L<sub>5 </sub>to the top of S<sub>1</sub>was also measured.</p> <p>Results and discussion</p> <p>49 women were diagnosed with radiographic osteoarthritis of the lumbar spine, while 63 women had no evidence of osteoarthritis and served as controls. The two groups were matched for age and body build, as it is expressed by BMI. No statistically significant differences were found in the lordotic angles between the two groups</p> <p>Conclusions</p> <p>There is no difference in lordosis between those affected with lumbar spine osteoarthritis and those who are disease free. It appears that osteoarthritis is not associated with the degree of lumbar lordosis.</p

    Technical design of the phase I Mu3e experiment

    Get PDF
    The Mu3e experiment aims to find or exclude the lepton flavour violating decay μ→eee at branching fractions above 10−16. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of 2⋅10−15. We present an overview of all aspects of the technical design and expected performance of the phase I Mu3e detector. The high rate of up to 108 muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements

    Technical design of the phase I Mu3e experiment

    Get PDF
    The Mu3e experiment aims to find or exclude the lepton flavour violating decay μeee\mu \rightarrow eee at branching fractions above 101610^{-16}. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of 210152\cdot 10^{-15}. We present an overview of all aspects of the technical design and expected performance of the phase~I Mu3e detector. The high rate of up to 10810^{8} muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements.Comment: 114 pages, 185 figures. Submitted to Nuclear Instruments and Methods A. Edited by Frank Meier Aeschbacher This version has many enhancements for better readability and more detail

    Seminaphthofluorescein-Based Fluorescent Probes for Imaging Nitric Oxide in Live Cells

    Get PDF
    Fluorescent turn-on probes for nitric oxide based on seminaphthofluorescein scaffolds were prepared and spectroscopically characterized. The Cu(II) complexes of these fluorescent probes react with NO under anaerobic conditions to yield a 20–45-fold increase in integrated emission. The seminaphthofluorescein-based probes emit at longer wavelengths than the parent FL1 and FL2 fluorescein-based generations of NO probes, maintaining emission maxima between 550 and 625 nm. The emission profiles depend on the excitation wavelength; maximum fluorescence turn-on is achieved at excitations between 535 and 575 nm. The probes are highly selective for NO over other biologically relevant reactive nitrogen and oxygen species including NO3–, NO2–, HNO, ONOO–, NO2, OCl–, and H2O2. The seminaphthofluorescein-based probes can be used to visualize endogenously produced NO in live cells, as demonstrated using Raw 264.7 macrophages.National Science Foundation (U.S.) (CHE-0611944)National Institutes of Health (U.S.) (K99GM092970

    Zinc homeostasis and signaling in health and diseases: Zinc signaling

    Get PDF
    The essential trace element zinc (Zn) is widely required in cellular functions, and abnormal Zn homeostasis causes a variety of health problems that include growth retardation, immunodeficiency, hypogonadism, and neuronal and sensory dysfunctions. Zn homeostasis is regulated through Zn transporters, permeable channels, and metallothioneins. Recent studies highlight Zn’s dynamic activity and its role as a signaling mediator. Zn acts as an intracellular signaling molecule, capable of communicating between cells, converting extracellular stimuli to intracellular signals, and controlling intracellular events. We have proposed that intracellular Zn signaling falls into two classes, early and late Zn signaling. This review addresses recent findings regarding Zn signaling and its role in physiological processes and pathogenesis

    Patterns of paediatric end-of-life care: a chart review across different care settings in Switzerland.

    Get PDF
    Paediatric end-of-life care is challenging and requires a high level of professional expertise. It is important that healthcare teams have a thorough understanding of paediatric subspecialties and related knowledge of disease-specific aspects of paediatric end-of-life care. The aim of this study was to comprehensively describe, explore and compare current practices in paediatric end-of-life care in four distinct diagnostic groups across healthcare settings including all relevant levels of healthcare providers in Switzerland. In this nationwide retrospective chart review study, data from paediatric patients who died in the years 2011 or 2012 due to a cardiac, neurological or oncological condition, or during the neonatal period were collected in 13 hospitals, two long-term institutions and 10 community-based healthcare service providers throughout Switzerland. Ninety-three (62%) of the 149 reviewed patients died in intensive care units, 78 (84%) of them following withdrawal of life-sustaining treatment. Reliance on invasive medical interventions was prevalent, and the use of medication was high, with a median count of 12 different drugs during the last week of life. Patients experienced an average number of 6.42 symptoms. The prevalence of various types of symptoms differed significantly among the four diagnostic groups. Overall, our study patients stayed in the hospital for a median of six days during their last four weeks of life. Seventy-two patients (48%) stayed at home for at least one day and only half of those received community-based healthcare. The study provides a wide-ranging overview of current end-of-life care practices in a real-life setting of different healthcare providers. The inclusion of patients with all major diagnoses leading to disease- and prematurity-related childhood deaths, as well as comparisons across the diagnostic groups, provides additional insight and understanding for healthcare professionals. The provision of specialised palliative and end-of-life care services in Switzerland, including the capacity of community healthcare services, need to be expanded to meet the specific needs of seriously ill children and their families
    corecore