203 research outputs found

    Evolution of the phase-space density and the Jeans scale for dark matter derived from the Vlasov-Einstein equation

    Full text link
    We discuss solutions of Vlasov-Einstein equation for collisionless dark matter particles in the context of a flat Friedmann universe. We show that, after decoupling from the primordial plasma, the dark matter phase-space density indicator Q remains constant during the expansion of the universe, prior to structure formation. This well known result is valid for non-relativistic particles and is not "observer dependent" as in solutions derived from the Vlasov-Poisson system. In the linear regime, the inclusion of velocity dispersion effects permits to define a physical Jeans length for collisionless matter as function of the primordial phase-space density indicator: \lambda_J = (5\pi/G)^(1/2)Q^(-1/3)\rho_dm^(-1/6). The comoving Jeans wavenumber at matter-radiation equality is smaller by a factor of 2-3 than the comoving wavenumber due to free-streaming, contributing to the cut-off of the density fluctuation power spectrum at the lowest scales. We discuss the physical differences between these two scales. For dark matter particles of mass equal to 200 GeV, the derived Jeans mass is 4.3 x 10^(-6) solar masses.Comment: 18 pages, 2 figures. Accepted for publication in JCA

    Meniere’s Disease Treatment

    Get PDF
    The Meniere’s disease is a chronic condition that requires treatment for long time and whose control is not always easy to achieve, requiring some multidrug treatments, and sometimes even procedures. We have many drugs and procedures to the treatment of Meniere’s disease which may be taken according to the stage of disease and individual features

    Caracterização quantitativa do sistema nervoso autônomo : estimação da taxa respiratória a partir do sinal de eletrocardiograma (ECG)

    Get PDF
    Trabalho de Conclusão de Curso (graduação)—Universidade de Brasília, Instituto de Ciências Exatas, Departamento de Ciência da Computação, 2019.Este trabalho propõe o estudo de uma abordagem alternativa e não invasiva para se obter características oriundas do sinal de respiração e de suas influências sobre o Sistema Nervoso Autônomo (SNA). Especificamente, procura-se verificar a validade do uso de um sinal respiratório extraído de um sinal de eletrocardiograma em um sistema que correlaciona sinais cardíacos e respiratórios e o grau de apneia do sono de um certo indivíduo. Para se alcançar tal objetivo, usaram-se dois conjuntos de dados: o primeiro consiste na seleção de 6 pacientes de um banco de 53 pacientes de unidades de tratamento intensivo; o segundo continha sinais de eletrocardiograma e respiração de 8 pacientes, divididos em 4 indívíduos com apneia e 4 pacientes sem apneia. Por meio da estimação da resposta ao impulso pelos métodos autoregressivo (ARX) e de funções base de Laguerre (FBL), foi possível obter parâmetros quantitativos que refletem a modulação do SNA a partir de um sistema com o sinal de respiração estimado. A partir desses modelos, foi possível compará-los com os parâmetros extraídos de um sistema com sinais de respiração obtidos por métodos convencionais, os quais foram tratados nesse estudo como sinais de referência. Assim, compararam-se esses sinais estimados e de referência por diferentes métricas: uma correlação cruzada foi aplicada entre os sinais estimado e de referência para se obter o nível de semelhança entre eles. Em seguida, realizou-se uma correlação entre os parâmetros de descrição da resposta ao impulso (RI) tanto para os modelos estimados quanto os de referência, com o intuito de se obter uma medida de similaridade no comportamento entre eles. Finalmente, procurou-se utilizar as técnicas ANOVA e K-Means com a finalidade de verificar a possibilidade de distinção entre pacientes apneicos e não-apneicos para esses parâmetros estimados e de referência. Nos resultados obtidos, observou-se uma diferença sensível na correlação cruzada dos sinais e na correlação dos parâmetros para bases de dados diferentes. Para o método ANOVA, foi possível observar que os parâmetros oriundos dos modelos criados com os sinais de respiração estimados não apresentaram diferença estatística na distinção entre pacientes apneicos e não-apneicos, algo que foi alcançado para os parâmetros provindos dos modelos com sinais de referência. Todavia, essa incerteza poderia ser possivelmente explicada por um número reduzido de amostras. Ademais, o método K-Means obteve 100% de acertos na segregação dos pacientes apneicos e não apneicos utilizando os parâmetros descritivos de RI dos modelos de referência; para os modelos com sinais estimados, dois pacientes apneicos foram incorretamente classificados. Pelos resultados obtidos, sugere-se a aplicação das metodologias descritas em uma base de dados maior e em diferentes bases de dados, a fim de se verificar algumas da questões levantadas ao longo dessa pesquisa.This work proposes the study of an alternative and non-invasive approach to acquire characteristics from the respiratory signal and its influences to the Autonomic Nervous System. Specifically, this work seeks to verifiy the validity of the application of a respiratory signal extracted from an electrocardiogram signal in a system that correlates cardiac and respiratory signals and the index of sleep apnea of a certain subject. In order to reach this goal, two databases were used: the first one consists of a selection of 6 subjects from a database of 53 critically-ill patients in intensive care units; the second data set contain electrocardiogram and respiratory signals of 8 subjects, divided between 4 individuals without apnea and 4 subjects with apnea. By means of the impulse response with the autregressive (ARX) and Laguerre basis functions (LBF) models, it was possible to extract quantitative parameters that reflect the Autonomic Nervous System modulation from a system with the estimated respiratory signal. These models made it possible to compare these parameters with the ones from a system with respiratory signals obtained from more conventional methods, which were treated in this study as reference signals. Therefore, the estimated and reference respiratory signals were compared by different metrics: a cross-correlation analysis was applied between these signals in order to measure the level of similarity between them. Then, the correlation technique was applied to the descriptive parameters of the impulse response for both the estimated and reference models. This was done with the purpose of obtaining a measure of similarity in the behavior of these parameters. Finally, the ANOVA and K-Means techniques were used in order to verify the possibility of distinction between apneic and non-apneic patients with the estimated and reference parameters. In the results obtained from these metrics, a sensible difference was observed in the cross-correlation for the signals and in the correlation for the parameters for the two different databases. In the ANOVA method, the parameters from the models with estimated respiratory signals weren’t statistically different in the distinction between apneic and non-apneic patients, unlike the models with the reference signals. However, this statistical uncertainty can possibly be explained by a reduced number of samples. Moreover, the K-Means method obtained 100% accuracy in the process of distinguishing patients with and without apnea using the impulse response parameters from the reference models; for the estimated models, however, two apneic patients were incorrectly classified as non-apneic. With the results obtained in this study, the application of the procedures used in this study in a larger database and in different databases is suggested, in order to verify some of the observations raised throughout this research

    Contrato por safra : segurança jurídica para empregados e empregadores

    Get PDF
    Trabalho de Conclusão de Curso (graduação)—Universidade de Brasília, Faculdade de Direito, 2018.O presente trabalho tem como objetivo apresentar as bases teóricas do contrato por safra e apresentá-lo dentro da realidade do mercado de pó-de-carnaúba na região de mata de cocais, no meio norte geográfico brasileiro. Para tanto, apresentar-se-á as bases contratuais relevantes, tanto civis quanto trabalhistas. Posteriormente, aprofundar-se-á dentro das premissas basilares do contrato por safra, apresentando-se seu cerne. Seguindo nessa perspectiva, será apresentado o mercado do pó-de-carnaúba, desenvolvido na vegetação de transição que se tem entre a floresta amazônica e a caatinga nordestina, região que abrange principalmente áreas dos estados do Maranhão, Piauí e Ceará. Trazer essa realidade a tona e apresentar uma funcionalidade do jurídico para sanar possíveis litígios nessa realidade é o principal objetivo deste trabalho, apresentando uma funcionalidade prática para um instrumento jurídico, dentro de uma realidade que necessita de visibilidade.This work has the intent to present the theoretical basis of the employment contract by crop, and present it within the reality of the carnauba powder market, in the “mata de cocais”, located in the mid-northern geographic region of Brazil. For doing so, the relevant contractual basis will be presented, both in civil right and in labor law. Afterwards, the work will dig into of the basic premises of the employment contract by crop, to reveal it’s core. Following that perspective, will be presented the carnauba powder market, which is developed in the transition vegetation there is between the Amazon rainforest and the northeastern caatinga, that covers mostly the states of Maranhão, Piauí e Ceará. To bring forth this reality and to present a legal functionality for solving possible conflicts in this area is the main purpose of this work, and present a practical use for a legal instrument, within a reality that needs more social and governmental visibility

    Faster Unbalanced Private Set Intersection

    Get PDF
    Protocols for Private Set Intersection (PSI) are important cryptographic primitives that perform joint operations on datasets in a privacy-preserving way. They allow two parties to compute the intersection of their private sets without revealing any additional information beyond the intersection itself. Unfortunately, PSI implementations in the literature do not usually employ the best possible cryptographic implementation techniques. This results in protocols presenting computational and communication complexities that are prohibitive, particularly in the case when one of the participants is a low-powered device and there are bandwidth restrictions. This paper builds on modern cryptographic engineering techniques and proposes optimizations for a promising one-way PSI protocol based on public-key cryptography. For the case when one of the parties holds a set much smaller than the other (a realistic assumption in many scenarios) we show that our improvements and optimizations yield a protocol that outperforms the communication complexity and the run time of previous proposals by around one thousand times

    Comparison of physical and mechanical properties of microwave-polymerized acrylic resin after disinfection in sodium hypochlorite solutions

    Get PDF
    This study evaluated the color stability, surface roughness and flexural strength of a microwave-polymerized acrylic resin after immersion in sodium hypochlorite (NaOCl), simulating 20 min of disinfection daily during 180 days. Forty disk-shaped (15 x 4 mm) and 40 rectangular (65 x 10 x 3 mm) specimens were prepared with a microwave-polymerized acrylic resin (Onda-Cryl). Specimens were immersed in either 0.5% NaOCl, 1% NaOCl, Clorox/Calgon and distilled water (control). Color measurements were determined by a portable colorimeter. Three parallel lines, separated by 1.0 mm, were registered on each specimen before and after immersion procedures to analyze the surface roughness. The flexural strength was measured using a 3-point bending test in a universal testing machine with a 50 kgf load cell and a crosshead speed of 1 mm/min. Data were analyzed statistically by ANOVA and Tukey's test (?=0.05). There was no statistically significant differences (p>0.05) among the solutions for color, surface roughness and flexural strength. It may be concluded that immersion in NaOCl solutions simulating short-term daily use during 180 days did not influence the color stability, surface roughness and flexural strength of a microwave-polymerized acrylic resin.Este estudo avaliou a estabilidade de cor, rugosidade superficial e resistência à flexão de resina acrílica polimerizada por microondas após desinfecção em hipoclorito de sódio, simulando 20 min de desinfecção diária durante 180 dias. Quarenta espécimes circulares (15 x 4 mm) e 40 retangulares (65 x 10 x 3 mm) foram preparados em resina acrílica polimerizada por microondas (Onda-Cryl). As amostras foram imersas em hipoclorito de sódio a 0,5%, hipoclorito de sódio a 1%, Clorox/Calgon e água destilada (controle). Medidas de cor foram determinadas por um espectrocolorímetro portátil. Três linhas paralelas, separadas por 1,0 mm, foram registradas em cada amostra antes e depois dos procedimentos de imersão para analisar a rugosidade superficial. A resistência à flexão foi medida utilizando um teste de flexão por 3 pontos em uma máquina universal de ensaios com uma célula de carga de 50 Kgf e uma velocidade de 1 mm/min. Os dados foram analisados estatisticamente por ANOVA e teste de Tukey (?=0,05). Não houve diferença estatisticamente significante (p>0,05) entre as soluções para cor, rugosidade superficial e resistência à flexão. Pode-se concluir que a imersão em soluções de hipoclorito de sódio, simulando um uso diário de curta duração durante 180 dias, não influenciou a estabilidade de cor, rugosidade superficial e resistência à flexão de resina acrílica polimerizada por microondas.FAPESPCNP

    Effect of different cleansers on the surface of removable partial denture

    Get PDF
    Removable partial dentures (RPD) demand specific hygienic cleaning and the combination of brushing with immersion in chemical solutions has been the most recommended method for control of biofilm. However, the effect of the cleansers on metallic components has not been widely investigated. This study evaluated the effect of different cleansers on the surface of RPD. Five disc specimens (12 mm x 3 mm metallic disc centered in a 38 x 18 x 4 mm mould filled with resin) were obtained for each experimental situation: 6 solutions [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) control] and 2 Co-Cr alloys [DeguDent (DD) and VeraPDI (VPDI)] were used for each experimental situation. A 180-day immersion was simulated and the measurements of roughness (Ra, µm) of metal and resin were analyzed using 2-way ANOVA and Tukey’s test. The surface changes and tarnishes were examined with a scanning electronic microscopy (SEM). In addition, energy dispersive x-ray spectrometry (EDS) analysis was carried out at representative areas. Visually, NaOCl and MI specimens presented surface tarnishes. The roughness of materials was not affected by the solutions (p>0.05). SEM images showed that NaOCl and MI provided surface changes. EDS analysis revealed the presence of oxygen for specimens in contact with both MI and NaOCl solutions, which might suggest that the two solutions promoted the oxidation of the surfaces, thus leading to spot corrosion. Within the limitations of this study, it may be concluded that the NaOCl and MI may not be suitable for cleaning of RPD.As próteses parciais removíveis (PPR) exigem higienização específica e a associação da escovação com imersão em soluções químicas tem sido o método mais recomendado para controle do biofilme. Entretanto, os efeitos destas soluções não são amplamente reportados em componentes metálicos. Este estudo avaliou o efeito de diferentes agentes de higienização na superfície dos componentes de uma PPR. Foram confeccionados 5 espécimes (disco metálico de 12 x 3 mm centralizado em uma tira de resina com 38 x 18 x 4 mm) para cada situação experimental: 6 soluções [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), hipoclorito de sódio 0,05% (HS) e água destilada (AD) como controle)] e 2 ligas de cobalto-cromo [DeguDent (DD) e Vera PDI (VPDI)] foram utilizadas para cada situação experimental. Foram simuladas imersões de 180 dias. As aferições de rugosidade (Ra, μm) tanto em porção metálica quanto em resina acrílica termopolimerizável foram submetidos ao ANOVA e ao teste de Tukey. As alterações superficiais e manchas foram examinadas por meio de microscopia eletrônica de varredura (MEV). Áreas de interesse foram submetidas à espectrometria por energia dispersiva por raios X (EDS). Visualmente, puderam ser verificadas manchas nas superfícies metálicas quando utilizados HS e MI. A rugosidade dos materiais não foi afetada pelas soluções (p>0,05). As fotomicrografias evidenciaram que HS e MI ocasionaram alterações superficiais. As análises de EDS revelaram a presença de oxigênio nos grupos HS e MI, o que pode sugerir que estas duas soluções causaram oxidação das superfícies, provocando pontos de corrosão. Dentre as limitações do presente estudo, pode-se concluir que estas soluções não são apropriadas para a higienização das PPR

    Violência contra Mulher: Notificações dos Profissionais da Saúde no Rio Grande do Sul

    Get PDF
    The aim of this study was to characterize the situations of violence against women reported by healthprofessionals in Rio Grande do Sul. A total of 20.999 reports were performed between 2010 and 2014. The most frequent reports included women aged 19 to 29 years old. The most frequent type of violence was physical, and the victim’s residence was the most frequent place. Most of perpetrators were male, partner or ex-partner of the victim. Women were referred more frequently to clinics and police station. The results can support strategies for prevention and coping violence against women. The study allowed identifying weaknesses in the report information, as well as in the referrals made, indicating the need for investments in the training of health professionals.Este estudo teve como objetivo caracterizar as situações de violência contra mulheres notificadas pelos profissionais da saúde no Rio Grande do Sul. Foram analisadas 20.999 notificações realizadas entre 2010 e 2014. As notificações incluíram, com maior frequência, mulheres de 19 a 29 anos. A violência física foi a mais predominante,sendo a residência da vítima o principal local de ocorrência. A maioria dos agressores era do gênero masculino, parceiros ou ex-parceiros íntimos. As mulheres foram encaminhadas com maior frequência para ambulatórios e delegacias. Os resultados podem subsidiar estratégias para prevenção e enfrentamento da violência contra a mulher. O estudo permitiu identificar fragilidades nas informações notificadas, bem como nos encaminhamentos realizados, indicando a necessidadede investimentos na capacitação dos profissionais da saúde
    corecore