24 research outputs found

    Structural assessment and seismic vulnerability of earthen historic structures. Application of sophisticated numerical and simple analytical models

    Get PDF
    Adobe constructions account for a significant portion of the built heritage, associated with early building techniques, material accessibility and low-cost. Nonetheless, adobe buildings, due to their low mechanical properties and overturning resistance, are subject to early structural damage, such as cracking, separation of structural elements and, possibly, collapse in areas of high seismic hazard. The lack of maintenance and absence of adequate retrofitting techniques usually intensifies the loss of historic fabric. The current paper, aims at the structural assessment and seismic safety, in current conditions, of the Church of Kuno Tambo, a religious adobe structure of the 17th century, in Cusco region, in Peru. The inspection and diagnosis involved sonic testing and damage mapping, while ambient vibration tests revealed the modal response of the structure. The assessment of seismic vulnerability, together with the necessity of retrofitting measures were verified through nonlinear static and pushover parametric analyses, complemented with a macro-block limit analysis and a performance based assessment, under local seismic criteria. A more realistic response from dynamically induced ground motions was performed, by a nonlinear time history analysis, according to the Eurocode 8 framework. Through an integrated approach, in situ inspection, testing, numerical and analytical modelling are associated under the scope of reproducing the existing structural damage, the sequence of inelastic behavior and verification of the necessity of retrofitting measures.The current work is part of the Seismic Retrofitting Project, of the Getty Conservation Institute and was partly supported by FCT (Portuguese Foundation for Science and Technology), within the INFRARISK PhD program and ISISE, project UID/ECl/04029/2013.info:eu-repo/semantics/publishedVersio

    On the modelling of infilled RC frames through strut models

    Get PDF
    Infill panels largely affect the seismic response of framed constructions. The wide variety in their mechanical and geometrical features has produced many different models and assumptions in their analytical representation. In this paper the simplest and most diffuse analytical approach, based on the introduction of equivalent struts, has been checked. An overview is presented, focusing on the strut dimensions, strength and number. Two case-studies, taken by two different experimental campaigns, have been considered and reproduced. The obtained results have been compared to the experimental ones, and some parameters have been checked for selecting the model to use for analysis

    Assessing reparability: simple tools for estimation of costs and performance loss of earthquake damaged reinforced concrete buildings

    No full text
    Tools for assessing building reparability via the estimation of expected performance loss (PL) and associated costs for repair of existing RC building classes damaged by an earthquake are presented. The assessment approach relies on the availability of a number of suitably developed: (i) capacity curves for representative building classes; (ii) curves relating global ductility demand μ to the expected PL for the same classes; and (iii) PL-cost for repair relationship calibrated on database collecting cost data of more than 2300 buildings damaged after 2009 L'Aquila earthquake. The tools are developed applying a simplified procedure involving the simulated design of existing building classes, the assumption of predefined collapse mechanism types and the analyses of the seismic behavior of equivalent SDOF systems representative of 'intact' and 'damaged' structures after an earthquake. The use of these tools may give useful preliminary indications to decision makers for establishing reparability priorities in the aftermath of damaging earthquakes or to insurance companies to value sound insurance premium for existing building classe
    corecore