22 research outputs found

    Optimal claim strategy in the automobile insurance market

    Get PDF
    Upon analyzing an extensive database on the Brazilian auto insurance market, we found a stylized fact: the frequency of claims is higher in the first months of contractual validity. In order to explain it, we propose a modified version of Venezia and Levy (1980) model, in which we show that pseudodeductible is lower at the beginning of the contract. The pseudodeductible is an unobservable threshold, higher than the deductible stipulated in the contract, below which the insuree has an incentive not to claim his losses. Given that the pseudodeductible is smaller at the beginning of the contract, the model predicts that there will be a higher frequency of losses (of lower value) being claimed in this period. In order to test this prediction, we regressed the logarithm of indemnities against dummies for the time of the contract, and we found that in the first quarter of the period the average value of claimed losses is approximately 2.21% lower than the second quarter. This information can be used by insurers to adjust the value of deductibles in the first months of contracts in order to reduce their claims rates.Ao analisar uma extensa base de dados elaborada pela SUSEP sobre o mercado se seguros de automóveis, encontramos um fato estilizado: a frequência de sinistros declarados é maior nos primeiros meses de vigência contratual. Para explicá-lo, propomos uma versão modificada do modelo de Venezia e Levy [1980], na qual mostramos que a pseudofranquia é menor no início do contrato. A pseudofranquia é um valor não observável, superior a franquia, até o qual o segurado tem incentivo a não declarar suas perdas. Portanto, se a pseudofranquia é menor no início do contrato, haverá uma frequência maior de perdas (de menor valor) sendo declaradas. Para testar o modelo, verificamos que os valores das perdas declaradas são, em média, menores nos primeiros meses do contrato. Obtivemos que no segundo trimestre de vigência contratual o valor médio das perdas declaradas é aproximadamente 2,1% maiores em relação ao primeiro trimestre. Além disso, no segundo quadrimestre as perdas declaradas são aproximadamente 2,5% maiores do que no primeiro

    Estratégia ótima para declarar perdas no mercado de seguros de automóveis

    No full text
    Resumo Ao analisar uma extensa base de dados sobre o mercado brasileiro de seguros de automóveis, encontramos um fato estilizado: a frequência de sinistros declarados é maior nos primeiros meses de vigência contratual. Para explicá-lo, propomos uma versão modicada do modelo de Venezia e Levy (1980), na qual demonstramos que a pseudofranquia é menor no início do contrato. A pseudofranquia é um valor não observável, superior à franquia estipulada em contrato, até o qual o segurado tem incentivo a não declarar suas perdas. Dado que a pseudofranquia é menor no início do contrato, o modelo prevê que haverá uma frequência maior de perdas (de menor valor) sendo declaradas neste período. Para testar esta previsão, regredimos o logaritmo das indenizações contra dummies de tempo, e obtivemos que no primeiro trimestre de vigência o valor médio das perdas declaradas é aproximadamente 2,21% menor em relação ao segundo trimestre. Esta informação pode ser utilizada pelas seguradoras para ajustar o valor das franquias nos primeiros meses dos contratos a fim de reduzir suas taxas de sinistralidade

    POLARIZATION OF NEUTRONS SCATTERED BY INTERMEDIATE AND HEAVY NUCLEI

    No full text
    Measurements of the polarization produced in the scattering of neutrons from heavy nuclei have been carried out at neutron energies of 380 and 980 kev. The Li/sup 7/(p,n)Be/sup 7/ reaction was used as a source of polarized neutrons. Right-left asymmetries in scattering of these neutrons from several elements ranging in atomic weight from 55 to 238 were measured at scattering angles of 55, 90, and 130 deg . With few exceptions the observed polarizations vary smoothly with atomic weight. Measured values of the polarization range from -0.11 to plus or minus 0.15 at 380 kev, and from --0.17 to plus or minus 0.20 at 980 kev. The results at 380-kev neutron energy are compared with values predicted by the complex square well potential modified by a surface spin-orbit interaction. Using several sets of well parameters it has not been possible to reproduce the experimental results. (auth

    Characteristics of large area silicon surface barrier detectors

    No full text
    This paper presents a detailed description of an upgraded silicon surface barrier (SE) detector and analysis of X and gamma radiation and of the spectra given by it. The most frequently used application of these detectors was in measurements and analyses of alpha spectra. However, analysis of spectra gained here presented a silicon surface barrier detector showing possibilities of their wider application in various nuclear techniques and technologies. This specially referes to the feasibility of their use in the conditions that are different from those in laboratories, such as mines, surroundings of nuclear power plants etc. Recorded spectra from Co-57, show that SE detectors are very acceptable in nuclear laboratories for nuclear spectroscopy at room temperatures. On the contrary, field application in nuclear techniques connected with the protection of the environment and counting systems is much wider, and the detector temperature could reach 60 degrees C. (C) 1997 Elsevier Science S.A.Symposium B: Thin Film Materials for Large Area Electronics at the European-Materials-Research-Society 1996 Spring Meeting, Jun 04-07, 1996, Strasbourg, Franc
    corecore