213 research outputs found

    Prevalence and genetic characterization of Cryptosporidium spp. In diarrheic children from Gonbad Kavoos city, Iran

    Get PDF
    Background: Cryptosporidium is an intestinal protozean parasite causing water-borne and foodborne outbreaks of diarrheal diseases. The present study was per-formed in order to find prevalence and subtypes of Cryptosporidium among children with diarrhea in Gonbad Kavoos City, Northern Iran. Methods: Diarrheic samples were collected from 547 children. The initial parasi-tological diagnosis was made based on detection of oocysts using the modified Ziehl-Neelsen acid-fast staining method. The positive microscopically samples were selected for sequence analysis of partial 60 kDa glycoprotein (gp60) gene. Results: Out of 547 collected samples, 27 (4.94) were positive for Cryptosporid-ium oocysts. Fifteen from 27 positive samples successfully amplified in PCR. Se-quences analysis of gp60 gene in 15 Cryptosporidium isolates revealed that all of them (100) were C. parvum. The results showed three subtypes of IIa subtype family (7 cases) including IIaA16G2R1, IIaA17G1R1, IIaA22G3R1 and one subtype of IId subtype family (8 cases). The most common allele was IId A17G1d (53.3). Conclusion: The predominance of zoonotic subtype families of C. parvum species (IIa, IId) in the present study is in concordance with previous studies in Iran and emphasizes the significance of zoonotic transmission of cryptosporidiosis in the country. © 2015, Tehran University of Medical Sciences (TUMS). All rights Reserved

    Optic nerve sonography in the diagnostic evaluation of pseudopapilledema and raised intracranial pressure: A cross-sectional study

    Get PDF
    Introduction. Differentiating pseudopapilledema from papilledema which is optic disk edema and a result of increased ICP (intracranial pressure) is important and can be done with noninvasive methods like orbital ultrasound examination. Method. This was a cross-sectional study in which patients with optic nerve head swelling were referred for LP exam after optic nerve head swelling diagnosis confirmation and having normal brain imaging (CT scan). Before LP (lumbar puncture) exam the patients were referred for optic nerve ultrasound test of both eyes. Results. Considering 5.7 mm as the upper limit for normal ONSD (optic nerve sheath diameter), sensitivity and negative predictive value of optic sonography in diagnosis of pseudopapilledema are 100 for both eyes. Calculated accuracy validity of ONSD measurement in detecting pseudopapilledema is 90 for the right eye and 87 for the left eye. Conclusion. Our study demonstrated a close correlation between optic nerve sheath dilation on ocular ultrasound and evidence of elevated ICP with optic disk swelling. With the aid of noninvasive diagnostic tests we can avoid unnecessary concerns along with expensive and invasive neurological investigations while targeting the correct diagnosis in bilateral optic disk swelling. Our study showed optic nerve sonography as a reliable diagnostic method for further usage. © 2015 Masoud Mehrpour et al

    Improved acoustics for semi-enclosed spaces in the proximity of residential buildings

    Get PDF
    Continuous urban densification exacerbates acoustic challenges for residents of housing complexes. They are confronted with higher noise immission from railway, road traffic, construction, as well as louder neighborhood acoustic environments. Thereby, not only noise immission indoors is associated with stress, annoyance, and sleep disturbance, but also the immediate outdoor living environment (e.g., courtyards, private gardens and playgrounds, etc.) can be acoustically unpleasant and annoying. This non-exhaustive narrative review paper elaborates on the role of a number of design parameters on improving the quality of the outdoor soundscape of housing complexes: architectural and morphological design, facade material characteristics, balconies, greenery, ground, background sounds, and several factors concerning quality of sounds (e.g., multisensory perception, holistic design, the relevance of space, context, social factors, co-creation, etc.). It mainly covers literature including both acoustical (e.g., sound pressure level and room acoustical parameters) and human/perceptual (e.g., comfort and annoyance) factors. A series of recommendations are presented here as to how the semi-enclosed outdoor spaces in the proximity of residential complexes can be acoustically improved

    Developing a Questionnaire for Iranian Women's Attitude on Medical Ethics in Vaginal Childbirth

    Get PDF
    Background: Vaginal delivery is one of the challenging issues in medical ethics. It is important to use an appropriate instrument to assess medical ethics attitudes in normal delivery, but the lack of tool for this purpose is clear. Objectives: The aim of this study was to develop and validate a questionnaire for the assessment of women’s attitude on medical ethics application in normal vaginal delivery. Patients and Methods: This methodological study was carried out in Iran in 2013 - 2014. Medical ethics attitude in vaginal delivery questionnaire (MEAVDQ) was developed using the findings of a qualitative data obtained from a grounded theory research conducted on 20 women who had vaginal childbirth, in the first phase. Then, the validation criteria of this tool were tested by content and face validity in the second phase. Exploratory factor analysis was used for construct validity and reliability was also tested by Cronbach’s alpha coefficient in the third phase of this study. SPSS version 13 was used in this study. The sample size for construct validity was 250 females who had normal vaginal childbirth. Results: In the first phase of this study (tool development), by the use of four obtained categories and nine subcategories from grounded theory and literature review, three parts (98-items) of this tool were obtained (A, B and J). Part A explained the first principle of medical ethics, part B pointed to the second and third principles of medical ethics, and part J explained the fourth principle of medical ethics. After evaluating and confirming its face and content validity, 75 items remained in the questionnaire. In construct validity, by the employment of exploratory factor analysis, in parts A, B and J, 3, 7 and 3 factors were formed, respectively; and 62.8%, 64% and 51% of the total variances were explained by the obtained factors in parts A, B and J, respectively. The names of these factors in the three parts were achieved by consideration of the loading factor and medical ethics principles. The subscales of MEAVDQ showed significant reliability. In parts A, B and J, Cronbach’s alpha coefficients were 0.76, 0.72 and 0.68, respectively and for the total questionnaire, it was 0.72. The results of the test–retest were satisfactory for all the items (ICC = 0.60 - 0.95). Conclusions: The present study showed that the 59-item MEAVDQ was a valid and reliable questionnaire for the assessment of women’s attitudes toward medical ethics application in vaginal childbirth. This tool might assist specialists in making a judgment and plan appropriate for women in vaginal delivery management

    Reliability of real�time ultrasound imaging for the assessment of trunk stabilizer muscles: A systematic review of the literature

    Get PDF
    Rehabilitative ultrasound (US) imaging is one of the popular methods for investigating muscle morphologic characteristics and dimensions in recent years. The reliability of this method has been investigated in different studies. As studies have been performed with different designs and quality, reported values of rehabilitative US have a wide range. The objective of this study was to systematically review the literature conducted on the reliability of rehabilitative US imaging for the assessment of deep abdominal and lumbar trunk muscle dimensions. The PubMed/MEDLINE, Scopus, Google Scholar, Science Direct, Embase, Physiotherapy Evidence, Ovid, and CINAHL databases were searched to identify original research articles conducted on the reliability of rehabilitative US imaging published from June 2007 to August 2017. The articles were qualitatively assessed; reliability data were extracted; and the methodological quality was evaluated by 2 independent reviewers. Of the 26 included studies, 16 were considered of high methodological quality. Except for 2 studies, all high�quality studies reported intraclass correlation coefficients (ICCs) for intra�rater reliability of 0.70 or greater. Also, ICCs reported for inter�rater reliability in high�quality studies were generally greater than 0.70. Among low�quality studies, reported ICCs ranged from 0.26 to 0.99 and 0.68 to 0.97 for intra� and inter�rater reliability, respectively. Also, the reported standard error of measurement and minimal detectable change for rehabilitative US were generally in an acceptable range. Generally, the results of the reviewed studies indicate that rehabilitative US imaging has good levels of both inter� and intra�rater reliability. © 2018 by the American Institute of Ultrasound in Medicine

    Proportional lumbar spine inter-vertebral motion patterns: a comparison of patients with chronic, non-specific low back pain and healthy controls

    Get PDF
    Introduction: Identifying biomechanical subgroups in chronic, non-specific low back pain (CNSLBP) populations from inter-vertebral displacements has proven elusive. Quantitative fluoroscopy (QF) has excellent repeatability and provides continuous standardised inter-vertebral kinematic data from fluoroscopic sequences allowing assessment of mid-range motion. The aim of this study was to determine whether proportional continuous IV rotational patterns were different in patients and controls. A secondary aim was to update the repeatability of QF measurement of range of motion (RoM) for inter-vertebral (IV) rotation
    corecore