842 research outputs found
Optimizing Antenna Arrays for Spatial Multiplexing: Towards 6G Systems
In this paper we discuss the design of antenna arrays to be used for multiplexing applications. In particular, we introduce a suitable performance index to analyze the effect of the antenna geometry and the distribution of users for the overall performance of Multi-User Multiple Input Multiple Output systems. By means of such performance index, antenna arrays can be designed so as to increase the number of multiplexed parallel sub-channels. Numerical results show that a proper design could allow to double the contemporary served users and the overall system throughput
Spectral and polarimetric characterization of the Gas Pixel Detector filled with dimethyl ether
The Gas Pixel Detector belongs to the very limited class of gas detectors
optimized for the measurement of X-ray polarization in the emission of
astrophysical sources. The choice of the mixture in which X-ray photons are
absorbed and photoelectrons propagate, deeply affects both the energy range of
the instrument and its performance in terms of gain, track dimension and
ultimately, polarimetric sensitivity. Here we present the characterization of
the Gas Pixel Detector with a 1 cm thick cell filled with dimethyl ether (DME)
at 0.79 atm, selected among other mixtures for the very low diffusion
coefficient. Almost completely polarized and monochromatic photons were
produced at the calibration facility built at INAF/IASF-Rome exploiting Bragg
diffraction at nearly 45 degrees. For the first time ever, we measured the
modulation factor and the spectral capabilities of the instrument at energies
as low as 2.0 keV, but also at 2.6 keV, 3.7 keV, 4.0 keV, 5.2 keV and 7.8 keV.
These measurements cover almost completely the energy range of the instrument
and allows to compare the sensitivity achieved with that of the standard
mixture, composed of helium and DME.Comment: 20 pages, 11 figures, 5 tables. Accepted for publication by NIM
Awake fiberoptic intubation in patients with stenosis of the upper airways. Utility of the laryngeal nerve block
Awake fiberoptic intubation (AFOI) is mandatory to manage difficult airways. Superior laryngeal nerve block (SLNB) could reduce risks and improve patient comfort. The aim of this study is to assess the procedural comfort of SLNB during AFOI in a population of patients undergoing upper airway oncological surgery. Forty patients were randomized into two groups and were treated with continuous infusion of remifentanil, topic anesthesia and intercricoid block. In the study group (=20), SLNB was performed with lidocaine (L-SLNB); in the control group (n=20) SLNB was performed using saline (S-SLNB). AFOI was more comfortable in the L-SLNB group compared to S-SLNB patients [FOICS ≤ 1 in 18 patients (90%) L-SLNB; 2 (10%) S-SLNB (P<0.001)]. Intubation was faster in L-SLNB (47.45 ±15.38 sec) than S-SLNB (80.15 ±37.91 sec) (p<0.001). The SLNB procedure during AFOI is a safe and comfortable procedure in a population of patients undergoing upper airways surgery. Time to intubation was shorter in L-SLNB than in S-SLNB
Low energy polarization sensitivity of the Gas Pixel Detector
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been
proposed to be included in many upcoming space missions to fill the gap of
about 30 years from the first (and to date only) positive measurement of
polarized X-ray emission from an astrophysical source. The estimated
sensitivity of the current prototype peaks at an energy of about 3 keV, but the
lack of readily available polarized sources in this energy range has prevented
the measurement of detector polarimetric performances.
In this paper we present the measurement of the Gas Pixel Detector
polarimetric sensitivity at energies of a few keV and the new, light, compact
and transportable polarized source that was devised and built to this aim.
Polarized photons are produced, from unpolarized radiation generated with an
X-ray tube, by means of Bragg diffraction at nearly 45 degrees.
The employment of mosaic graphite and flat aluminum crystals allow the
production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from
the diffraction of unpolarized continuum or line emission. The measured
modulation factor of the Gas Pixel Detector at these energies is in good
agreement with the estimates derived from a Monte Carlo software, which was up
to now employed for driving the development of the instrument and for
estimating its low energy sensitivity. In this paper we present the excellent
polarimetric performance of the Gas Pixel Detector at energies where the peak
sensitivity is expected. These measurements not only support our previous
claims of high sensitivity but confirm the feasibility of astrophysical X-ray
photoelectric polarimetry.Comment: 15 pages, 12 figures. Accepted for publication in NIM
- …