224 research outputs found

    Auto covariance computer

    Get PDF
    A laser velocimeter covariance processor which calculates the auto covariance and cross covariance functions for a turbulent flow field based on Poisson sampled measurements in time from a laser velocimeter is described. The device will process a block of data that is up to 4096 data points in length and return a 512 point covariance function with 48-bit resolution along with a 512 point histogram of the interarrival times which is used to normalize the covariance function. The device is designed to interface and be controlled by a minicomputer from which the data is received and the results returned. A typical 4096 point computation takes approximately 1.5 seconds to receive the data, compute the covariance function, and return the results to the computer

    Enhancement of Capabilities in Hyperspectral and Radar Remote Sensing for Environmental Assessment and Monitoring

    Get PDF
    The University of Utah, Department of Geography has developed a research and instructional program in satellite remote sensing and image processing. The University requested funds for the purchase of software licenses, mass storage for massive hyperspectral imager data sets, upgrades for the central data server to handle the additional storage capacity, a spectroradiometer for field data collection. These purchases have been made. This equipment will support research in one of the newest and most rapidly expanding areas of remote sensing

    Laser velocimeter systems analysis applied to a flow survey above a stalled wing

    Get PDF
    A laser velocimeter operating in the backscatter mode was used to survey the flow above a stalled wing. Polarization was used to separate the two orthogonal velocity components of the fringe-type laser velocimeter, and digital counters were used for data processing. The velocities of the kerosene seed particles were measured with less than 2 percent uncertainty. The particle velocity measurements were collected into histograms. The flow field survey was carried out above an aspect-ratio-8 stalled wing with an NACA 0012 section. The angle of attack was 19.5 deg, the Mach number was 0.49, and the Reynolds number was 1,400,000. The flow field was characterized by the periodic shedding of discrete vortices from near the crest of the airfoil

    Correlation of laser velocimeter measurements over a wing with results of two prediction techniques

    Get PDF
    The flow field at the center line of an unswept wing with an aspect ratio of eight was determined using a two dimensional viscous flow prediction technique for the flow field calculation, and a three dimensional potential flow panel method to evaluate the degree of two dimensionality achieved at the wing center line. The analysis was made to provide an acceptable reference for comparison with velocity measurements obtained from a fringe type laser velocimeter optics systems operating in the backscatter mode in the Langley V/STOL tunnel. Good agreement between laser velocimeter measurements and theoretical results indicate that both methods provide a true representation of the velocity field about the wing at angles of attack of 0.6 and 4.75 deg

    Serum Neurofilament Light, Glial Fibrillary Acidic Protein and Tau Are Possible Serum Biomarkers for Activity of Brain Metastases and Gliomas

    Get PDF
    BACKGROUND: Primary central nervous system (CNS) tumors and brain metastases (BMs) are major causes of morbidity and mortality, accompanied by low survival rates. Efforts to early discovery of CNS malignancies are critical. However, to date, there are no biomarkers approved for detection of cancer activity in the brain. Blood levels of neurofilament light (NfL) and tau, as well as glial fibrillary acidic protein (GFAp), show promise as biomarkers for brain injury in previous studies. Therefore, we performed a cross-sectional study to investigate correlations of those biomarkers with CNS activity of gliomas and BMs. METHODS: Serum samples of 36 participants of a single centered institution were tested for NfL, GFAp and tau with Simoa immunoassay, and correlated with clinical and radiological data. RESULTS: fL and GFAp levels were significantly associated with the state of intracranial disease (analysis of variance (ANOVA), P_{sNfL} = 0.03; ANOVA, P_{GFAp} = 0.03). Although statistically significant (P = 0.04), differences in concentrations were not clinically meaningful for tau levels. Serum NfL (sNfL) and GFAp concentrations were higher in the group of patients with CNS tumors with disease in progression versus CNS with stable disease (P = 0.03 and P = 0.01, respectively). In addition, sNfL were higher in patients with metastatic solid tumors with known BMs than in those with metastatic tumors with no BM (P = 0.0004). CONCLUSION: sNfL and GFAp both apparently vary closely with presence and activity of gliomas and BMs. Further studies in larger populations are needed to expand these findings

    Laser velocimeter survey about a NACA 0012 wing at low angles of attack

    Get PDF
    An investigation was conducted in the Langley V/STOL tunnel with a laser velocimeter to obtain measurements of airflow velocities about a wing at low angles of attack. The applicability of the laser velocimeter technique for this purpose in the V/STOL tunnel was demonstrated in this investigation with measurement precision bias calculated at -1.33 percent to 0.91 percent and a random uncertainty calculated at + or - 0.47 percent. Free stream measurements were obtained with this device and compared with velocity calculations from pitot static probe data taken near the laser velocimeter measurement location. The two measurements were in agreement to within 1 percent. Velocity measurement results about the centerline at 0.6 degrees angle of attack were typically those expected. At 4.75 degrees, the velocity measurements indicated that a short laminar separation bubble existed near the leading edge with an oscillating shear layer

    Extreme Learning Machine for land cover classification

    Full text link
    This paper explores the potential of extreme learning machine based supervised classification algorithm for land cover classification. In comparison to a backpropagation neural network, which requires setting of several user-defined parameters and may produce local minima, extreme learning machine require setting of one parameter and produce a unique solution. ETM+ multispectral data set (England) was used to judge the suitability of extreme learning machine for remote sensing classifications. A back propagation neural network was used to compare its performance in term of classification accuracy and computational cost. Results suggest that the extreme learning machine perform equally well to back propagation neural network in term of classification accuracy with this data set. The computational cost using extreme learning machine is very small in comparison to back propagation neural network.Comment: 6 pages, mapindia 2008 conferenc

    Dobutamine stress echocardiography: Prevalence of a nonischemic response in a low-risk population

    Full text link
    The problems of population referral bias in the calculation of specificity in diagnostic testing for coronary artery disease have been previously described. Previous studies investigating the sensitivity and specificity of dobutamine stress echocardiography (DSE) have been subject to pretest and posttest referral biases, largely as a result of the requirement for coronary arteriography. This study determines the normalcy rate for DSE by examining a population at statistically low risk for coronary artery disease. The probability of significant coronary artery disease was determined for 828 consecutive patients referred for DSE at the University of Michigan, and groups were identified with <10% and <5% probability of disease. Four of 72 patients (5.6%) with a normal baseline echocardiogram and a probability of coronary artery disease of <10%, and three of 38 (7.9%) with a probability of <5% were found to have an abnormal DSE, yielding normalcy rates of 94.4% and 92.1%, respectively. The area of abnormality involved the posterior circulation in three of four patients (75%). This study demonstrates that DSE has a normalcy rate of 92% to 94% and is an accurate test for excluding the presence of significant coronary artery disease.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/30826/1/0000488.pd

    Scheduling Algorithms for Procrastinators

    Full text link
    This paper presents scheduling algorithms for procrastinators, where the speed that a procrastinator executes a job increases as the due date approaches. We give optimal off-line scheduling policies for linearly increasing speed functions. We then explain the computational/numerical issues involved in implementing this policy. We next explore the online setting, showing that there exist adversaries that force any online scheduling policy to miss due dates. This impossibility result motivates the problem of minimizing the maximum interval stretch of any job; the interval stretch of a job is the job's flow time divided by the job's due date minus release time. We show that several common scheduling strategies, including the "hit-the-highest-nail" strategy beloved by procrastinators, have arbitrarily large maximum interval stretch. Then we give the "thrashing" scheduling policy and show that it is a \Theta(1) approximation algorithm for the maximum interval stretch.Comment: 12 pages, 3 figure

    Right atrial spontaneous contrast: echocardiographic and clinical features

    Full text link
    We describe the clinical and echocardiographic findings in eight patients with right atrial spontaneous echo contrast who were identified from 648 consecutive patients undergoing transesophageal echocardiography. Common findings in these patients were right atrial enlargement (8 patients), tricuspid regurgitation (7 patients), atrial fibrillation or flutter (6 patients), elevated right ventricular pressure (5 patients), moderate or severe mitral valve disease (5 patients), and right to left interatrial shunts (3 patients). Right heart catheterization in three patients showed markedly elevated right atrial, right ventricular, and pulmonary artery pressures. Two patients had thromboembolic events — one patient had recurrent pulmonary emboli, and another patient with an atrial septal aneurysm had recurrent transient ischemic attacks. Right atrial echo contrast is an uncommon finding at echocardiography that is associated with severe right heart dysfunction. It may also be associated with paradoxical or pulmonary embolism.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/42538/1/10554_2005_Article_BF01137904.pd
    corecore