132 research outputs found

    Nuclear modules for space electric propulsion

    Get PDF

    Scoping Calculations of Power Sources for Nuclear Electric Propulsion

    Get PDF
    This technical memorandum describes models and calculational procedures to fully characterize the nuclear island of power sources for nuclear electric propulsion. Two computer codes were written: one for the gas-cooled NERVA derivative reactor and the other for liquid metal-cooled fuel pin reactors. These codes are going to be interfaced by NASA with the balance of plant in order to make scoping calculations for mission analysis

    SUR, a program to generate error covariance files

    Full text link
    Covariance matrices were calculated for the sup238sup 238U, sup241sup 241Pu, and sup239sup 239Pu fission cross sections and for the sub23sub 23sub8sub 8 sup240sup 240Pu, sup241sup 241Pu, and sup239sup 239Pu capture cross sections. A computer program was written which uses the evaluated ENDF/B data files and the measured or evaluated (from other evaluations) cross sections for the calculation of the uncertainty files. An effort has been made to make the output of the program consistent with the ENDF/B error files format. A user's manual for the present code and references utilized in the covariance matrix calculations are given. (auth

    Quantum Phonon Optics: Coherent and Squeezed Atomic Displacements

    Full text link
    In this paper we investigate coherent and squeezed quantum states of phonons. The latter allow the possibility of modulating the quantum fluctuations of atomic displacements below the zero-point quantum noise level of coherent states. The expectation values and quantum fluctuations of both the atomic displacement and the lattice amplitude operators are calculated in these states---in some cases analytically. We also study the possibility of squeezing quantum noise in the atomic displacement using a polariton-based approach.Comment: 6 pages, RevTe

    Beta decay of 115-In to the first excited level of 115-Sn: Potential outcome for neutrino mass

    Full text link
    Recent observation of beta decay of 115-In to the first excited level of 115-Sn with an extremely low Q_beta value (Q_beta ~ 1 keV) could be used to set a limit on neutrino mass. To give restriction potentially competitive with those extracted from experiments with 3-H (~2 eV) and 187-Re (~15 eV), atomic mass difference between 115-In and 115-Sn and energy of the first 115-Sn level should be remeasured with higher accuracy (possibly of the order of ~1 eV).Comment: 9 pages, 3 figures; talk at the NANP'05 Conferenc

    CPT and Lorentz Tests in Penning Traps

    Get PDF
    A theoretical analysis is performed of Penning-trap experiments testing CPT and Lorentz symmetry through measurements of anomalous magnetic moments and charge-to-mass ratios. Possible CPT and Lorentz violations arising from spontaneous symmetry breaking at a fundamental level are treated in the context of a general extension of the SU(3) x SU(2) x U(1) standard model and its restriction to quantum electrodynamics. We describe signals that might appear in principle, introduce suitable figures of merit, and estimate CPT and Lorentz bounds attainable in present and future Penning-trap experiments. Experiments measuring anomaly frequencies are found to provide the sharpest tests of CPT symmetry. Bounds are attainable of approximately 102010^{-20} in the electron-positron case and of 102310^{-23} for a suggested experiment with protons and antiprotons. Searches for diurnal frequency variations in these experiments could also limit certain types of Lorentz violation to the level of 101810^{-18} in the electron-positron system and others at the level of 102110^{-21} in the proton-antiproton system. In contrast, measurements comparing cyclotron frequencies are sensitive within the present theoretical framework to different kinds of Lorentz violation that preserve CPT. Constraints could be obtained on one figure of merit in the electron-positron system at the level of 101610^{-16}, on another in the proton-antiproton system at 102410^{-24}, and on a third at 102510^{-25} using comparisons of HH^- ions with antiprotons.Comment: 31 pages, published in Physical Review

    The deuteron: structure and form factors

    Get PDF
    A brief review of the history of the discovery of the deuteron in provided. The current status of both experiment and theory for the elastic electron scattering is then presented.Comment: 80 pages, 33 figures, submited to Advances in Nuclear Physic

    Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT

    Get PDF
    BACKGROUND: The use of selective internal radiation therapy (SIRT) is rapidly increasing, and the need for quantification and dosimetry is becoming more widespread to facilitate treatment planning and verification. The aim of this project was to develop an anthropomorphic phantom that can be used as a validation tool for post-SIRT imaging and its application to dosimetry. METHOD: The phantom design was based on anatomical data obtained from a T1-weighted volume-interpolated breath-hold examination (VIBE) on a Siemens Aera 1.5 T MRI scanner. The liver, lungs and abdominal trunk were segmented using the Hermes image processing workstation. Organ volumes were then uploaded to the Delft Visualization and Image processing Development Environment for smoothing and surface rendering. Triangular meshes defining the iso-surfaces were saved as stereo lithography (STL) files and imported into the Autodesk® Meshmixer software. Organ volumes were subtracted from the abdomen and a removable base designed to allow access to the liver cavity. Connection points for placing lesion inserts and filling holes were also included. The phantom was manufactured using a Stratasys Connex3 PolyJet 3D printer. The printer uses stereolithography technology combined with ink jet printing. Print material is a solid acrylic plastic, with similar properties to polymethylmethacrylate (PMMA). RESULTS: Measured Hounsfield units and calculated attenuation coefficients of the material were shown to also be similar to PMMA. Total print time for the phantom was approximately 5 days. Initial scans of the phantom have been performed with Y-90 bremsstrahlung SPECT/CT, Y-90 PET/CT and Tc-99m SPECT/CT. The CT component of these images compared well with the original anatomical reference, and measurements of volume agreed to within 9 %. Quantitative analysis of the phantom was performed using all three imaging techniques. Lesion and normal liver absorbed doses were calculated from the quantitative images in three dimensions using the local deposition method. CONCLUSIONS: 3D printing is a flexible and cost-efficient technology for manufacture of anthropomorphic phantom. Application of such phantoms will enable quantitative imaging and dosimetry methodologies to be evaluated, which with optimisation could help improve outcome for patients
    corecore