503 research outputs found

    A new model of master of philosophy in physiological sciences

    Get PDF
    The objectives of Master of Philosophy (MPhil) in Physiological Sciences are: 1) to describe the new ways in which anatomy, biochemistry and physiology on one hand, and microbiology, pathology and pharmacology on other hand meet their functional requirements through multidisciplinary integrated concepts; 2) to elucidate relationships between cell biology, molecular biology and molecular genetics by connecting dots of how cell functions are driven by molecules and being controlled by genes. This forms the basis of cell, molecular and genetics [CMG] module upon which 7 multidisciplinary modules of Physiological Sciences follow; 3) these 24 credit hours provide the physiological basis for PhD studies as well as faculty development to enhance learning abilities of medical student; 4) the modules constitute Cardio- Respiratory Physiological Sciences, GI and Renal Physiological Sciences, Neurosciences, Endo-Reproductive Physiological Sciences.; 5) it has integrated microbiology, pathology and pharmacology in a unique way through CMG of microbes leading to associated pathology and mechanisms of prescribed drugs; 6) it has additional synopsis and thesis friendly course work leading to comprehensive examinations; 7) the year two deals with research work of 6 credit hours leading to defense of thesis; 8) The MPhil in Physiological Sciences is fundamentally different from what is being offered elsewhere. It prepares and offers a good spring board to dovetail PhD studies as well as faculty and institutional development. This is the first study that deals with innovative programmes in research, learning and education in the field of physiological sciences. This broad-based MPhil would make its recipients competent, critical, confident and productive learner. This is a completely unique design of a curriculum that has no comparable examples elsewhere. Our mission is to educate graduate students in the field of Physiological Sciences such that they have a complete grasp over the broad-based integrated concepts of basic health sciences. Upon completion of their education, the students will be able to use the duality of imagination and skepticism. Hence, the students will contribute to their fields by unfolding their creative energy

    Sonographic fetal biometry charts for a Pakistani cohort.

    Get PDF
    This study aimed to develop growth centiles at different gestational weeks for fetal biparietal diameter, abdominal circumference, femur length and head circumference in a Pakistani cohort. Data were collected at a tertiary referral hospital from pregnant women at gestational ages 13-40 weeks referred for obstetric ultrasound as a part of routine antenatal care. A total of 1599 fetal sonographic biometric measurements were collected after screening for the inclusion criteria. For each measurement, separate regression models were derived to estimate the mean, standard deviation and reference percentiles at each week of gestational age for this cohort. The best fitting model for each variable was selected. These charts will help radiologists and clinicians in predicting dates of delivery, assessing fetal growth and identifying intrauterine fetal insufficiency in the Pakistani population

    Small optic suspensions for Advanced LIGO input optics and other precision optical experiments

    Get PDF
    We report on the design and performance of small optic suspensions developed to suppress seismic motion of out-of-cavity optics in the Input Optics subsystem of the Advanced LIGO interferometric gravitational wave detector. These compact single stage suspensions provide isolation in all six degrees of freedom of the optic, local sensing and actuation in three of them, and passive damping for the other three

    Characterization of thermal effects in the Enhanced LIGO Input Optics

    Get PDF
    We present the design and performance of the LIGO Input Optics subsystem as implemented for the sixth science run of the LIGO interferometers. The Initial LIGO Input Optics experienced thermal side effects when operating with 7 W input power. We designed, built, and implemented improved versions of the Input Optics for Enhanced LIGO, an incremental upgrade to the Initial LIGO interferometers, designed to run with 30 W input power. At four times the power of Initial LIGO, the Enhanced LIGO Input Optics demonstrated improved performance including better optical isolation, less thermal drift, minimal thermal lensing and higher optical efficiency. The success of the Input Optics design fosters confidence for its ability to perform well in Advanced LIGO

    Future Smartphone: MIMO Antenna System for 5G Mobile Terminals

    Get PDF
    In this article, an inverted L-shaped monopole eight elements Multiple Input Multiple Output (MIMO) antenna system is presented. The multi-antenna system is designed on a low cost 0.8 mm thick FR4 substrate having dimensions of 136 x 68 mm(2) resonating at 3.5GHz with a 6dB measured bandwidth of 450MHz, and with inter element isolation greater than 15 dB and gain of 4 dBi. The proposed design consists of eight inverted L-shaped elements and parasitic L-shaped strips extending from the ground plane. These shorted stripes acted as tuning stubs for the four inverted L-shaped monopole elements on the side of chassis. This is done to achieve the desired frequency range by increasing the electrical length of the antennas. A prototype is fabricated, and the experimental results show good impedance matching with reasonable measured isolation within the desired frequency range. The MIMO performances, such as envelope correlation coefficient (ECC) and mean effective gain (MEG) are also calculated along with the channel capacity of 38.1bps/Hz approximately 2.6 times that of 4 x 4 MIMO system. Due to its simple shape and slim design, it may be a potential chassis for future handsets. Therefore, user hand scenarios, i.e. both single and dual hand are studied. Also, the effects of hand scenarios on various MIMO parameters are discussed along with the SAR. The performance of the proposed system in different scenarios suggests that the proposed structure holds promising future within the next generation radio smart phones

    Overview of Advanced LIGO Adaptive Optics

    Full text link
    This is an overview of the adaptive optics used in Advanced LIGO (aLIGO), known as the thermal compensation system (TCS). The thermal compensation system was designed to minimize thermally-induced spatial distortions in the interferometer optical modes and to provide some correction for static curvature errors in the core optics of aLIGO. The TCS is comprised of ring heater actuators, spatially tunable CO2_{2} laser projectors and Hartmann wavefront sensors. The system meets the requirements of correcting for nominal distortion in Advanced LIGO to a maximum residual error of 5.4nm, weighted across the laser beam, for up to 125W of laser input power into the interferometer

    Evidence of continued injecting drug use after attaining sustained treatment-induced clearance of the hepatitis C virus: implications for reinfection

    Get PDF
    Background: People who inject drugs (PWID) are at the greatest risk of hepatitis C virus (HCV) infection, yet are often denied immediate treatment due to fears of on-going risk behaviour. Our principal objective was to examine evidence of continued injecting drug use among PWID following successful treatment for HCV and attainment of a sustained viral response (SVR). Methods: PWID who attained SVR between 1992 and June 2012 were selected from the National Scottish Hepatitis C Clinical Database. Hospitalisation and mortality records were sourced for these patients using record linkage techniques. Our primary outcome variable was any hospitalisation or death, which was indicative of injecting drugs post-SVR. Results: The cohort comprised 1170 PWID (mean age at SVR 39.6y; 76% male). The Kaplan Meier estimate of incurring the primary outcome after three years of SVR was 10.59% (95% CI, 8.75–12.79) After adjusting for confounding, the risk of an injection related hospital episode or death post-SVR was significantly increased with advancing year of SVR: AHR:1.07 per year (95% CI, 1.01–1.14), having a pre-SVR acute alcohol intoxication-related hospital episode: AHR:1.83 (95% CI, 1.29–2.60), and having a pre-SVR opiate or injection-related hospital episode: AHR:2.59 (95% CI, 1.84–3.64). Conclusion: Despite attaining the optimal treatment outcome, these data indicate that an increasing significant minority of PWID continue to inject post-SVR at an intensity which leads to either hospitalisation or death and increased risk of reinfection

    Competency mapping framework for regulating professionally oriented degree programmes in higher education

    Get PDF
    Recognition of the huge variation between professional graduate degree programmes and employer requirements, especially in the construction industry, necessitated a need for assessing and developing competencies that aligned with professionally oriented programmes. The purpose of this research is to develop a competency mapping framework (CMF) in this case for quantity surveying honours degree programmes. The graduate competency threshold benchmark (GCTB) is a key component of the CMF. Therefore, the CMF contains the mapping process, the template documents and the benchmark. The research adopted literature review, pilot study, case studies (including semi-structured interviews) and expert forum in developing the framework. The framework developed in this research provides new insight into how degree programmes map against competencies. Thus, the framework can be applied more widely, to other professional degree programmes, for monitoring and improving the quality and professional standards of construction degree programmes by accrediting bodies. This should connect construction graduates more effectively to the industry

    Hierarchical Hough all-sky search for periodic gravitational waves in LIGO S5 data

    Full text link
    We describe a new pipeline used to analyze the data from the fifth science run (S5) of the LIGO detectors to search for continuous gravitational waves from isolated spinning neutron stars. The method employed is based on the Hough transform, which is a semi-coherent, computationally efficient, and robust pattern recognition technique. The Hough transform is used to find signals in the time-frequency plane of the data whose frequency evolution fits the pattern produced by the Doppler shift imposed on the signal by the Earth's motion and the pulsar's spin-down during the observation period. The main differences with respect to previous Hough all-sky searches are described. These differences include the use of a two-step hierarchical Hough search, analysis of coincidences among the candidates produced in the first and second year of S5, and veto strategies based on a χ2\chi^2 test.Comment: 7 pages, 2 figures, Amaldi08 proceedings, submitted to JPC
    corecore