128 research outputs found

    Noninferiority of Preservative-free Versus BAK-preserved Latanoprost-timolol Fixed Combination Eye Drops in Patients With Open-angle Glaucoma or Ocular Hypertension

    Get PDF
    Précis: Noninferiority of efficacy was demonstrated for a preservative-free latanoprost-timolol fixed combination compared with a BAK-containing formulation at 84 days after treatment in patients with open-angle glaucoma or ocular hypertension. Purpose: The purpose of this study was to compare the effect on intraocular pressure and safety of preservative-free latanoprost-timolol fixed combination (T2347) to benzalkonium chloride-preserved latanoprost-timolol fixed combination in patients with open-angle glaucoma or ocular hypertension. Methods: Phase III, randomized, parallel-group, investigator-masked study in 10 countries. A total of 242 patients aged 18 years or older with open-angle glaucoma or ocular hypertension in both eyes controlled with a preserved latanoprost-timolol fixed combination (15.7±2.4 mm Hg overall before inclusion) were randomized at day 0 with no washout period to receive the preservative-free alternative T2347 (N=127) or remain on the preserved comparator (N=115) for 84 days. Intraocular pressure changes from day 0 were measured at 9:00 am (±1 hour) on day 42 and day 84, and noninferiority of T2347 to the preserved comparator was analyzed statistically at day 84. Safety parameters were also reported. Results: The mean change in intraocular pressure from baseline to day 84 was -0.49±1.80 mm Hg for preservative-free T2347 and -0.49±2.25 mm Hg for the preserved comparator. These results met the noninferiority limits. Similar results were observed at day 42. There was no difference between groups in the incidence of adverse events or ocular signs. The total ocular symptoms score was better for T2347 than BPLT upon instillation at day 84 (45.9%/44.3%/9.8% of patients with improvement/no change/worsening vs. 33.6%/47.3%/19.1%; P=0.021), reflecting improvements in individual symptoms such as irritation/burning/stinging (P<0.001), and itching (P<0.01) on day 84. Conclusions: Preservative-free latanoprost-timolol fixed combination T2347 showed noninferior efficacy compared with the preserved comparator and was well tolerated

    Biodegradable collagen matrix implant vs mitomycin-C as an adjuvant in trabeculectomy: a 24-month, randomized clinical trial

    Get PDF
    AIM: To verify the safety and efficacy of Ologen (OLO) implant as adjuvant compared with low-dosage mitomycin-C (MMC) in trabeculectomy. METHODS: This was a prospective randomized clinical trial with a 24-month follow-up. Forty glaucoma patients (40 eyes) were assigned to trabeculectomy with MMC or OLO. Primary outcome includes target IOP at ≤21, ≤17, and ≤15 mm Hg; complete (target IOP without medications), and qualified success (target IOP regardless of medications). Secondary outcomes include bleb evaluation, according to Moorfields Bleb Grading System (MBGS); spectral domain optical coherence tomography (SD-OCT) examination; number of glaucoma medications; and frequency of postoperative adjunctive procedures and complications. RESULTS: The mean preoperative IOP was 26.5 (±5.2) in MMC and 27.3 (±6.0) in OLO eyes, without statistical significance. One-day postoperatively, the IOP dropped to 5.2 (±3.5) and 9.2 (±5.5) mm Hg, respectively (P=0.009). The IOP reduction was significant at end point in all groups (P=0.01), with a mean IOP of 16.0 (±2.9) and 16.5 (±2.1) mm Hg in MMC and OLO, respectively. The rates and Kaplan-Meier curves did not differ for both complete and qualified success at any target IOP. The bleb height in OLO group was higher than MMC one (P<0.05). SD-OCT analysis of successful/unsuccessful bleb in patients with or without complete success at IOP ≤17  mm Hg indicated a sensitivity of 83% and 73% and a specificity of 75% and 67%, respectively, for MMC and OLO groups. No adverse reaction to OLO was noted. CONCLUSIONS: Our results suggest that OLO implant could be a new, safe, and effective alternative to MMC, with similar long-term success rate

    H19 Antisense RNA Can Up-Regulate Igf2 Transcription by Activation of a Novel Promoter in Mouse Myoblasts

    Get PDF
    It was recently shown that a long non-coding RNA (lncRNA), that we named the 91H RNA (i.e. antisense H19 transcript), is overexpressed in human breast tumours and contributes in trans to the expression of the Insulin-like Growth Factor 2 (IGF2) gene on the paternal chromosome. Our preliminary experiments suggested that an H19 antisense transcript having a similar function may also be conserved in the mouse. In the present work, we further characterise the mouse 91H RNA and, using a genetic complementation approach in H19 KO myoblast cells, we show that ectopic expression of the mouse 91H RNA can up-regulate Igf2 expression in trans despite almost complete unmethylation of the Imprinting-Control Region (ICR). We then demonstrate that this activation occurs at the transcriptional level by activation of a previously unknown Igf2 promoter which displays, in mouse tissues, a preferential mesodermic expression (Pm promoter). Finally, our experiments indicate that a large excess of the H19 transcript can counteract 91H-mediated Igf2 activation. Our work contributes, in conjunction with other recent findings, to open new horizons to our understanding of Igf2 gene regulation and functions of the 91H/H19 RNAs in normal and pathological conditions

    24-h Efficacy of Glaucoma Treatment Options

    Full text link

    Biomechanical Stresses in Computer-Aided Design and in Data Entry

    No full text
    A study of the risk factors of musculoskeletal disorders (MSDs) of the upper limbs was carried out on 2 populations, 1 performing a computer-aided design (CAD) task and the other performing a data entry task. A questionnaire on MSD complaints and working life was completed by a sample of each population. Biomechanical measurements of the forces, the angles, and the repetitiveness of movements of the upper limbs were carried out on some operators in each sample. It emerged that complaints of the upper limbs seem to be linked to the use of input devices. The grip forces exerted when using the keyboard and mouse were higher in CAD than in data entry

    Incidence of Stress and Psychosocial Factors on Musculoskeletal Disorders in CAD and Data Entry

    No full text
    A comparative study concerning the incidence of psychosocial factors and stress on musculoskeletal disorders (MSD) was conducted on 30 males carrying out a computer-aided design (CAD) task and on 26 females carrying out a data entry task. Both populations completed a questionnaire concerning complaints of MSD, stress symptoms, psychosocial factors and working life. This study showed that the work context was more favourable to the data entry task operators than to the CAD task operators. In addition, there were relationships in CAD and in data entry between complaints of MSD and stress variables as well as between anguish and psychosocial factors. This field study has shown the importance of stress and of the work context in the occurrence of MSD in computer work

    Rétine et glaucome : implications thérapeutiques

    No full text
    • …
    corecore