37 research outputs found

    Etude des propriétés physico-chimiques de silices lamellaires synthétiques : le rôle de l'eau

    No full text
    This study is devoted to the hydration and swelling behavior of a synthetic layered silica: magadiite, which formula can be written as Na2Si14Ü29.9H20. This mineral of unknown crystallographic structure was obtained by hydrothermal synthesis and subsequently exchanged with H+, K+, Mg2+ and Ca2+. Ail the samples were characterized by chemical, thermal and texturai analyses, XRD, 29Si NMR and IR.Magadiite is formed by platelets about 2!J.m in length, which thickness inversely depends on cation polarisability. The layer formed by six-membered rings of silica that do not contain the interlayer cation, is not significantly affected by the nature of the exchangeable species. Except for H-magadiite, the water BET specifie surface area is much higher than the nitrogen one. Hydration was followed by water adsorption gravimetry, XRD and IR (including deuteration experiments) under controlled water pressures, and 29Si NMR and Raman under adjustable vacuum. The hydration of monovalent magadiites occurs in two steps. At low relative pressure, water molecules are in a C1 symmetry. For higher relative pressure ,the second step of hydration leads to water molecules with a C2v symmetry. This scheme remains valid for magnesium but ail the phenomena occur at much higher relative pressure. On the contrary, calcium is located between two Si-O- bonds of the silica framework. Even high water contents do not induce calcium displacement from its initial position.Cette étude contribue à la compréhension des mécanismes d'hydratation et de gonflement de silices lamellaires synthétiques. Le solide utilisé, dont la structure cristallographique est inconnue, est une magadiite, Na2Si14029·9H20, obtenue par synthèse hydrothermale et dont les ions sodium ont ensuite été échangés par H+, K+, Mg2+ et Ca2+. Ces échantillons ont été caractérisés par analyses chimiques, thermiques, texturales, DRX, RMN du 29Si et IR. La magadiite se présente sous forme de plaquettes d'environ 2 11-m de largeur, dont l'épaisseur varie à l'inverse de la polarisabilité du cation compensateur. Ses feuillets silicatés, peu affectés par le changement de cation compensateur, sont constitués de cycles à six tétraèdres qui, à l'inverse d'autres minéraux lamellaires, ne contiennent pas le cation interfoliaire. A l'exception de la forme protonée, elle développe, comme les matériaux gonflants, une surface spécifique à l'eau beaucoup plus importante que la surface spécifique à l'azote. L'hydratation a été suivie pargravimétrie d'adsorption d'eau, DRX et IR à différentes pressions relatives en eau et deutération, RMN du 29Si et Raman sous différentes conditions de mise sous vide. L'hydratation des magadiites monovalentes a lieu en deux étapes. A faible pression relative, les molécules d'eau se trouvent en symétrie C1. A plusforte pression relative, la seconde étape du gonflement génère des molécules d'eau en symétrie C2v. Ce schéma d'hydratation reste valable lorsque le magnésium est le cation interfoliaire, avec toutefois des étapes de gonflement retardées par rapport à celles des cations monovalents. En revanche, le calcium, bien que divalent et de taille équivalente au sodium, se place entre deux liaisons Si-0- du feuillet et les molécules d'eau ne parviennent pas à le perturber

    Synthèse des données de mesurage en fibres courtes d’amiante obtenues dans le cadre de la campagne INRS pour la détermination des facteurs de protection assignés des appareils de protection respiratoire utilisés en chantier de désamiantage

    No full text
    The purpose of this campaign was to determine, by META analysis, the protection factors assigned to respiratory protective devices worn by asbestos removal operators during the process of removing asbestos-containing materials on level 2 and 3 sites, in accordance with the regulations in force. during the campaign. Even if this campaign focused on the measurement of so-called WHO fibers (length > 5 µm, diameter 3), an evaluation of the concentrations of short asbestos fibers (length 3) was also performed.This summary presents the main measurement results for short asbestos fibers from the campaign. It is based on the use of measurements taken on 6 level 3 asbestos removal sites and on 3 level 2 sites.Synthèse des données de mesurage en fibres courtes d'amiante obtenues dans le cadre de la campagne INRS pour la détermination des facteurs de protection assignés des appareils de protection respiratoire utilisés en chantier de désamiantage Synthèse des données de mesurage en fibres courtes d'amiante obtenues dans le cadre de la campagne INRS pour la détermination des facteurs de protection assignés des appareils de protection respiratoire utilisés en chantier de désamiantag

    Synthèse des données de mesurage en fibres courtes d’amiante obtenues dans le cadre de la campagne INRS pour la détermination des facteurs de protection assignés des appareils de protection respiratoire utilisés en chantier de désamiantage

    No full text
    The purpose of this campaign was to determine, by META analysis, the protection factors assigned to respiratory protective devices worn by asbestos removal operators during the process of removing asbestos-containing materials on level 2 and 3 sites, in accordance with the regulations in force. during the campaign. Even if this campaign focused on the measurement of so-called WHO fibers (length > 5 µm, diameter 3), an evaluation of the concentrations of short asbestos fibers (length 3) was also performed.This summary presents the main measurement results for short asbestos fibers from the campaign. It is based on the use of measurements taken on 6 level 3 asbestos removal sites and on 3 level 2 sites.Synthèse des données de mesurage en fibres courtes d'amiante obtenues dans le cadre de la campagne INRS pour la détermination des facteurs de protection assignés des appareils de protection respiratoire utilisés en chantier de désamiantage Synthèse des données de mesurage en fibres courtes d'amiante obtenues dans le cadre de la campagne INRS pour la détermination des facteurs de protection assignés des appareils de protection respiratoire utilisés en chantier de désamiantag

    Workplace Respiratory Protection Factors during Asbestos Removal Operations

    No full text
    International audienceNumerous changes have been made to the French labour regulations in recent years relating to the prevention of risks of exposure to asbestos fibres for operators removing asbestos-containing materials. These changes refer to the method used to count fibres, the collective and personal protective devices to be used on these worksites, and the occupational exposure limit value, which was reduced to 10 f/L on 2 July 2015. In this context, this study assessed the level of respiratory protection afforded by supplied-air respirators and powered air purifying respirators by monitoring exposure for several operators on nine worksites. The levels of dustiness measured in personal samples taken outside masks showed significant evidence of potential exposure during removal of asbestos-containing plaster or sprayed asbestos, and when using abrasive blasting to treat asbestos-containing materials. For these tasks outside concentration regularly exceeds 25000 f/L. Measurements inside masks were generally low, under 10 f/L, except in some situations involving the removal of asbestos-containing plaster. This partial penetration of fibres inside masks could be due to the highLes évolutions de la réglementation française du travail concernant la prévention des risques d’exposition aux fibres d’amiante des opérateurs de désamiantage ont été nombreuses ces dernières années. Elles concernent la méthode de comptage des fibres, les équipements de protection collective et individuelle à mettre en place sur ces chantiers et la valeur limite d’exposition professionnelle réduite à 10 f.L-1 au 2 juillet 2015. Dans ce contexte, la protection respiratoire de plusieurs opérateurs équipés d’appareils à adduction d’air et d’appareils à ventilation assistée a été évaluée lors de cette étude sur 9 chantiers. Les mesures d’empoussièrement individuel obtenues à l’extérieur des masques ont mis en évidence le risque important d’exposition lors des procédés de retrait de plâtre amianté, de retrait de flocage ou de sablage de matériau amianté. Pour ces tâches, l'empoussièrement individuel sur opérateur dépasse régulièrement 25000 f.L-1. Les mesures à l’intérieur des masques présentent des valeurs globalement faibles, inférieures à 10 f.L-1, sauf lors de certaines activités de retrait de plâtre amianté. Une explication de la pénétration des fibres à l’intérieur des masques pourrait être le fort encrassement lié à ce matériau. Les distributions de facteur de protection obtenues pour les deux types d’appareil de protection respiratoire étudiés sont très larges et les valeurs de 5ème percentile sont respectivement égales à 236 et 104 pour les appareils à adduction d'air et les appareils à ventilation assistée. Ce travail rappelle la priorité à accorder à la protection collective dans la prévention du risque amiante
    corecore