3,139 research outputs found
Runtime Distributions and Criteria for Restarts
Randomized algorithms sometimes employ a restart strategy. After a certain
number of steps, the current computation is aborted and restarted with a new,
independent random seed. In some cases, this results in an improved overall
expected runtime. This work introduces properties of the underlying runtime
distribution which determine whether restarts are advantageous. The most
commonly used probability distributions admit the use of a scale and a location
parameter. Location parameters shift the density function to the right, while
scale parameters affect the spread of the distribution. It is shown that for
all distributions scale parameters do not influence the usefulness of restarts
and that location parameters only have a limited influence. This result
simplifies the analysis of the usefulness of restarts. The most important
runtime probability distributions are the log-normal, the Weibull, and the
Pareto distribution. In this work, these distributions are analyzed for the
usefulness of restarts. Secondly, a condition for the optimal restart time (if
it exists) is provided. The log-normal, the Weibull, and the generalized Pareto
distribution are analyzed in this respect. Moreover, it is shown that the
optimal restart time is also not influenced by scale parameters and that the
influence of location parameters is only linear
A white dwarf bound to the transiting planetary system WASP-98
WASP-98 is a planetary system containing a hot Jupiter transiting a late-G dwarf. A fainter star 12″ distant has previously been identified as a white dwarf, with a distance and proper motion consistent with a physical association with the planetary system. We present spectroscopy of the white dwarf, with the aim of determining its mass, radius and temperature and hence the age of the system. However, the spectra show the featureless continuum and lack of spectral lines characteristic of the DC class of white dwarfs. We therefore fitted theoretical white dwarf spectra to the ugriz apparent magnitudes and Gaia DR2 parallax of this object in order to determine its physical properties and the age of the system. We find that the system is old, with a lower limit of 3.6 Gyr, but theoretical uncertainties preclude a precise determination of its age. Its kinematics are consistent with membership of the thick disc, but do not allow us to rule out the thin-disc alternative. The old age and low metallicity of the system suggest it is subject to an age-metallicity relation, but analysis of the most metal-rich and metal-poor transiting planetary systems yields only insubstantial evidence of this. We conclude that the study of bound white dwarfs can yield independent ages to planetary systems, but such analysis may be better-suited to DA and DB rather than DC white dwarfs
Spatiotemporal summation of perimetric stimuli in healthy observers
Spatial summation of perimetric stimuli has been used to derive conclusions about the spatial extent of retinal-cortical convergence, mostly from the size of the critical area of summation (Ricco's area, RA) and critical number of retinal ganglion cells (RGCs). However, spatial summation is known to change dynamically with stimulus duration. Conversely, temporal summation and critical duration also vary with stimulus size. Such an important and often neglected spatiotemporal interaction has important implications for modeling perimetric sensitivity in healthy observers and for formulating hypotheses for changes measured in disease. In this work, we performed experiments on visually heathy observers confirming the interaction of stimulus size and duration in determining summation responses in photopic conditions. We then propose a simplified computational model that captures these aspects of perimetric sensitivity by modelling the total retinal input, the combined effect of stimulus size, duration, and retinal cones-to-RGC ratio. We additionally show that, in the macula, the enlargement of RA with eccentricity might not correspond to a constant critical number of RGCs, as often reported, but to a constant critical total retinal input. We finally compare our results with previous literature and show possible implications for modeling disease, especially glaucoma
WASP-20 IS A CLOSE VISUAL BINARY WITH A TRANSITING HOT JUPITER
We announce the discovery that WASP-20 is a binary stellar system, consisting of two components separated by 0.2578 ± 0farcs0007 on the sky, with a flux ratio of 0.4639 ± 0.0015 in the K-band. It has previously been assumed that the system consists of a single F9 V star, with photometric and radial velocity signals consistent with a low-density transiting giant planet. With a projected separation of approximately 60 au between the two components, the detected planetary signals almost certainly originate from the brighter of the two stars. We reanalyze previous observations allowing for two scenarios, "planet transits A" and "planet transits B," finding that both cases remain consistent with a transiting gas giant. However, we rule out the "planet transits B" scenario because the observed transit duration requires star B to be significantly evolved, and therefore have an age much greater than star A. We outline further observations that can be used to confirm this finding. Our preferred "planet transits A" scenario results in the measured mass and radius of the planet increasing by 4σ and 1σ, respectively
Comparison of clinical knowledge management capabilities of commercially-available and leading internally-developed electronic health records
<p>Abstract</p> <p>Background</p> <p>We have carried out an extensive qualitative research program focused on the barriers and facilitators to successful adoption and use of various features of advanced, state-of-the-art electronic health records (EHRs) within large, academic, teaching facilities with long-standing EHR research and development programs. We have recently begun investigating smaller, community hospitals and out-patient clinics that rely on commercially-available EHRs. We sought to assess whether the current generation of commercially-available EHRs are capable of providing the clinical knowledge management features, functions, tools, and techniques required to deliver and maintain the clinical decision support (CDS) interventions required to support the recently defined "meaningful use" criteria.</p> <p>Methods</p> <p>We developed and fielded a 17-question survey to representatives from nine commercially available EHR vendors and four leading internally developed EHRs. The first part of the survey asked basic questions about the vendor's EHR. The second part asked specifically about the CDS-related system tools and capabilities that each vendor provides. The final section asked about clinical content.</p> <p>Results</p> <p>All of the vendors and institutions have multiple modules capable of providing clinical decision support interventions to clinicians. The majority of the systems were capable of performing almost all of the key knowledge management functions we identified.</p> <p>Conclusion</p> <p>If these well-designed commercially-available systems are coupled with the other key socio-technical concepts required for safe and effective EHR implementation and use, and organizations have access to implementable clinical knowledge, we expect that the transformation of the healthcare enterprise that so many have predicted, is achievable using commercially-available, state-of-the-art EHRs.</p
High penetrances of BRCA1 and BRCA2 mutations confirmed in a prospective series
Penetrances of BRCA1 and BRCA2 mutations have been derived from retrospective studies, implying the possibility of ascertainment biases to influence the results
Recommended from our members
Quantifying intermolecular interactions of ionic liquids using cohesive energy densities
For ionic liquids (ILs), both the large number of possible cation + anion combinations and their ionic nature provide a unique challenge for understanding intermolecular interactions. Cohesive energy density, ced, is used to quantify the strength of intermolecular interactions for molecular liquids, and is determined using the enthalpy of vaporization. A critical analysis of the experimental challenges and data to obtain ced for ILs is provided. For ILs there are two methods to judge the strength of intermolecular interactions, due to the presence of multiple constituents in the vapour phase of ILs. Firstly, cedIP, where the ionic vapour constituent is neutral ion pairs, the major constituent of the IL vapour. Secondly, cedC+A, where the ionic vapour constituents are isolated ions. A cedIP dataset is presented for 64 ILs. For the first time an experimental cedC+A, a measure of the strength of the total intermolecular interaction for an IL, is presented. cedC+A is significantly larger for ILs than ced for most molecular liquids, reflecting the need to break all of the relatively strong electrostatic interactions present in ILs. However, the van der Waals interactions contribute significantly to IL volatility due to the very strong electrostatic interaction in the neutral ion pair ionic vapour. An excellent linear correlation is found between cedIP and the inverse of the molecular volume. A good linear correlation is found between IL cedIP and IL Gordon parameter (which are dependent primarily on surface tension). ced values obtained through indirect methods gave similar magnitude values to cedIP. These findings show that cedIP is very important for understanding IL intermolecular interactions, in spite of cedIP not being a measure of the total intermolecular interactions of an IL. In the outlook section, remaining challenges for understanding IL intermolecular interactions are outlined
Recommended from our members
Advice about diet and smoking for people with or at risk of age-related macular degeneration: a cross-sectional survey of eye care professionals in the UK.
BACKGROUND: In the absence of a cure, there has been considerable interest in attempts to prevent or reduce the progression of age-related macular degeneration (AMD) by targeting particular modifiable risk factors. The aim of this study was to conduct a cross-sectional survey of the current practice of UK eye care professionals in relation to advice given on diet and other lifestyle modifications for patients with or at risk of AMD. METHODS: Optometrists and ophthalmologists on the membership databases of professional organisations for the two professions were invited to participate in an online survey. The survey was open for 12 weeks between July and September 2012. RESULTS: A total of 1,468 responses were received (96.3% from optometrists and 3.7% from ophthalmologists). The response rate of those receiving the invitation was 16.2% (1,414/8735) for optometrists and 6% (54/1460) for ophthalmologists. A majority of respondents reported that they frequently provide dietary advice to patients with established AMD (67.9%) and those at risk of AMD (53.6%). Typical advice consisted of a recommendation to eat plenty of leafy green vegetables and eat more oily fish. The decision to recommend nutritional supplements was based on the risk of progression to advanced AMD, with approximately 93% of respondents recommending supplementation in a patient with advanced AMD in one eye. However for the majority, the type of supplement recommended did not comply with current best research evidence, based on the findings of the Age-related Eye Disease Study (AREDS). Only one in three optometrists regularly assessed smoking status and advised on smoking cessation. CONCLUSIONS: Within a large sample of eye care professionals, consisting predominantly of optometrists, who responded to a cross-sectional survey, there was active engagement in providing nutritional advice to patients with or at risk of AMD. However, the results demonstrate a need to raise awareness of the evidence underpinning the use of nutritional supplements together with an increased involvement in targeted smoking cessation
- …