41 research outputs found
Osteoblast adhesion on scaffolds of pla-plg-hydroxyapatite-chitosan-zinc by electroactivation
This paper presents results of the study of the phenomenon of electroactivation of system cell- polylactic acid (PLA) and polyglycolic acid (PLG) with additions of bioactive elements of chitosan (q), bioceramic (bc) and zinc. The main purpose was to explain the increase in the adhesion of cells as a result of the change in the hydrophilicity of the matrix cell regeneration and the variation in intracellular ion exchange, induced by the application of electric overpotential and bioactive elements additions to the polymers
Evaluation of corrosion by picking aisi-sae stainless steel 630 hardened by precipitation in synthetic sea water by electricity techniques
In this research, the stainless steel AISI-SAE 630 was studied under two conditions: manufacturing condition and after a thermal treatment, with the purpose of eliminating stress possibly produced during the service time, in an environment simulating the sea water conditions, in order to analyze the behavior of this material under these conditions, during 35 days. the techniques used were spectroscopy of impedances (Eis), cyclical polarization, and differential aeration test and critical pitting temperature (cpt), in order to determine the corrosion rate by pitting, and the cpt. the results showed that the techniques of Eis and Rp are not the most adequate for measuring the corrosion rate by pitting. the test specimen without treatment presented a highest susceptibility to the pitting corrosion with Ep value smaller, which was confrmed by the profle depth, giving as a result a higher rate, probably for absence of tantalum in this material. the cpt for the stainless steel was of 29±1°c, which is very close to the temperature of service, bein this variable (temperature) the cause of the deterioration of the material. En la presente investigación se estudió el acero inoxidable AISI-SAE 630 en estado de entrega y después de un tratamiento térmico, con el fin de eliminar tensiones posiblemente producidas durante el tiempo de servicio, en un medio que simuló las condiciones del agua de mar, para conocer el comportamiento del material bajo estas condiciones, en un tiempo de treinta y cinco dÃas. se emplearon las técnicas electroquÃmicas de espectroscopia de impedancias (Eis), polarización cÃclica, y las pruebas de aireación diferencial y temperatura crÃtica de picado (cpt), con el fin de determinar la velocidad de corrosión por picado, y la cpt. Los resultados mostraron que las técnicas de EIS y Rp no son las más adecuadas para medir la velocidad de corrosión por picado. La probeta "blanco" presentó una mayor susceptibilidad a la corrosión por picado dado que el valor de Ep fue menor, además para esta probeta la profundidad de picado fue mayor, lo cual se confrmó por el perfl de profundidad, dando como resultado una velocidad de corrosión más alta, probablemente por la ausencia de ta en este material. La cpt para el acero inoxidable aisi-saE 630 fue de 29±1°c, la cual está muy cercana a la temperatura de servicio, siendo esta variable (temperatura) quien haya sido la causante del deterioro del material. 
Evaluation of corrosion of AISI SAE 1020 steel in gasoline-bioethanol mixtures of 5, 10, 15, 20 and 100% by gravimetrical and electrochemicals techniques
En la búsqueda de nuevos y mejores combustibles de fuente renovable, el bioetanol surge como principal alternativa; esté además de económico, contribuye en gran manera con la disminución de los gases que ocasionan el efecto invernadero. El presente estudio tuvo como objetivo caracterizar el comportamiento electroquÃmico de un acero AISI 1020 en contacto con mezclas bioetanol-gasolina, tomando como base para las pruebas estáticas diferentes concentraciones (E5, E10, E15, E20 y E100) y tiempos (0, 7, 14, 21 y 28 dÃas), a una temperatura de 24°C aproximadamente. Las pruebas que se realizaron fueron: pérdida de peso mediante el ensayo de gravimetrÃa y pruebas electroquÃmicas (Tafel y EIS), mediante las cuales se pudo determinar la velocidad de corrosión del acero en exposición a las diferentes mezclas. Se observó que la velocidad de corrosión se encuentra influenciada por una capa porosa e inestable que se forma
como producto del efecto corrosivo sobre el acero; el comportamiento analizado de las pruebas de gravimetrÃa En la búsqueda de nuevos y mejores combustibles de fuente renovable, el bioetanol surge como principal alternativa; esté además de económico, contribuye en gran manera con la disminución de los gases que ocasionan el efecto invernadero. El presente estudio tuvo como objetivo caracterizar el comportamiento electroquÃmico de un acero AISI 1020 en contacto con mezclas bioetanol-gasolina, tomando como base para las pruebas estáticas diferentes concentraciones (E5, E10, E15, E20 y E100) y tiempos (0, 7, 14, 21 y 28 dÃas), a una temperatura de 24°C aproximadamente. Las pruebas que se realizaron fueron: pérdida de peso mediante el ensayo de gravimetrÃa y pruebas electroquÃmicas (Tafel y EIS), mediante las cuales se pudo determinar la velocidad de corrosión del acero en exposición a las diferentes mezclas. Se observó que la velocidad de corrosión se encuentra influenciada por una capa porosa e inestable que se forma como producto del efecto corrosivo sobre el acero; el comportamiento analizado de las pruebas de gravimetrÃa coincidió con los resultados obtenidos de las pruebas electroquÃmicas. coincidió con los resultados obtenidos de las pruebas electroquÃmicas.Abstract: The search for renewable source fuels, bioethanol emerged as the best alternative, due to be the most economical, and besides, it greatly contributes to the reduction of gases that cause the greenhouse effect. The objective of this study is to characterize the electrochemical behavior of AISI 1020 steel in contact with bioethanol-gasoline mixtures, based on static test for different concentrations (E5, E10, E15, E20 y E100) and times (0, 7, 14, 21, and 28 days) and a temperature of approximately 24°C. the tests performed were weight loss by gravimetry and electrochemical tests (Tafel and EIS), with which the corrosion rate of steel in exposure to different mixture was determined. It was observed that the corrosion rate is influenced by the porous and unstable layer forms as a result of present corrosion on the stele. The analyzed behavior of gravimetry test coincided with the obtained results from electrochemical test
Evaluación experimental de la resistencia a la corrosión de un acero aisi-sae 4140 implantado con iones de nitrógeno
Se estudió la resistencia a la corrosión de un acero AISI-SAE 4140 implantado con iones de Nitrógeno mediante la técnica 3DII (Implantación Iónica Tridimensional). Se evaluaron diferentes rugosidades de las muestras implantadas mediante técnicas electroquÃmicas de Rp, EIS y Tafel en una salmuera al 3% de NaCl, donde se obtuvo la mayor resistencia a la corrosión para el material implantado con menor rugosidad. Se produjo la formación de una posible capa protectora estable con la inmersión de las muestras en el electrolito de trabajo para tiempos superiores a 240 horas
Electrochemical analysis of the degradation of nitrided zirconia 3Y-TZP
Zirconia is a material that is susceptible to changes in its structure from the tetragonal to the monoclinic phase caused by variations in temperature or by contact with water. One way of achieving the stability of the tetragonal phase at low temperatures is by incorporating anionic gaps in its crystal lattice through doping procedures with aliovalent anions such as nitrogen. Nitrogen replaces the oxygen in the crystal lattice, which stabilizes the tetragonal structure of zirconia at low temperatures. The aim of this research was to evaluate the degradation of nitrided zirconia 3Y-TZP after it was immersed in artificial saliva for 0, 7, 14, and 21 days. Interfacial processes such as oxide-formation were assessed simultaneously using the electrochemical impedance spectroscopy test. Additionally, morphological, topographic, and composition changes were analyzed in the degradation process using SEM-EDS and AFM.La circonia es un material susceptible a cambios en su estructura de la fase tetragonal a monoclÃnica, ocasionados por cambios en la temperatura o contacto con agua. Una manera de alcanzar la estabilidad de la fase tetragonal a bajas temperaturas es a través de la incorporación de vacancias aniónicas en su estructura cristalina por medio de procedimientos de dopado con aniones aliovalentes como el nitrógeno. El nitrógeno reemplaza el oxÃgeno en la estructura cristalina y estabiliza la estructura tetragonal de la circonia a bajas temperaturas. El objetivo de este trabajo fue evaluar la degradación de la circonia 3Y-TZP nitrurada a través de su inmersión en saliva artificial por 0, 7,14 y 21 dÃas, evaluando los procesos interfaciales como la formación de óxidos a través de espectroscopia por impedancia electroquÃmica. Adicionalmente se analizó la morfologÃa, topografÃa y cambios de composición en el proceso de degradación empleando SEM-EDS y AF
Relación entre las propiedades mecánicas y tribológicas de Ti6AL4V ELI nitrurado mediante descarga intensa de plasma
This paper presents the study of the tribological behavior, rigidity and hardness, of the Ti6Al4V ELI alloy surface, after the performance of a glow discharge nitriding process at 450, 480 and 520 °C. The tribological pair used was metal-metal (Ti6Al4V ELI pin - Ti6Al4V ELI pre-treated disc) for the respective calculation of the coefficient of friction. Nanoindentation tests were performed with an ultra-high hardness tip with a known stiffness modulus, which provided the average hardness and Young's modulus in GPa according to ISO 14577 and ASTM G99-95 standards, respectively. Also, for the characterization of the substrate, electronic scanning microscopy, atomic force microscopy, and X-ray diffraction were used, to obtain, thus, important elasti-plastic behavioral characteristics, before and after the glow discharge plasma nitriding process was applied to the alloy.En este trabajo se estudió el comportamiento tribológico, la rigidez y dureza, de la superficie de la aleación Ti6Al4V ELI después de llevar a cabo un tratamiento de nitruración por descarga intensa de plasma a temperaturas de 450, 480 y 520 °C. El par tribológico empleado fue metal-metal (pin de Ti6Al4V ELI - disco de Ti6Al4V ELI con tratamiento) para el respectivo cálculo del coeficiente de fricción. Los ensayos de nanoindentación se realizaron con una punta de ultra alta dureza de módulo de rigidez conocido, que permitió obtener la dureza promedio y el módulo de Young en GPa, de acuerdo con las normas ISO 14577 y ASTM G99-95 respectivamente. Para la caracterización del sustrato, se empleó microscopia electrónica de barrido, microscopia de fuerza atómica y difracción de rayos X, obteniendo asà caracterÃsticas importantes del comportamiento elástico-plástico, antes y después de aplicarse la nitruración a la aleación por descarga intensa de plasm
Application of Micro-Raman Spectroscopy for the Quantitative Analysis of Vitrinite Reflectance in Medium and High Rank Colombian Coals
Los cambios estructurales y el grado de madurez de tres carbones colombianos de las provincias de Santander y Antioquia se estudiaron utilizando un método de ajuste de curva simple y rápido de los parámetros RBS (la distancia entre la banda G y la banda D), FWHM-G (ancho total en la mitad del máximo de la banda G) y AR (área del espectro Raman), obtenido por deconvolución y resolución de banda de los espectros Micro-Raman. Los resultados fueron comparados mediante análisis morfológicos y quÃmicos utilizando un microscopio electrónico de barrido SEM acoplado con un detector EDS de rayos X de estado sólido. Se obtuvo un porcentaje de reflectancia de vitrinita (%Ro) de 4.3 %, 3.8 % y 0.07 %, un porcentaje de carbono por análisis EDS de 91.47 %, 87.78 %, 73.4 %, una descripción morfológica por análisis SEM presentando superficies lisa, rugosa y rugosa-grumosa y tamaño de poro entre 0.7 µm - 0.8 µm, 1.3 µm - 1.5µm y 0.2 µm - 0.7 µm para las muestras de tipo antracita, semi-antracita y bituminoso, respectivamente. Los resultados mostraron que, con base en este método, fue posible obtener un modelo que permite analizar y caracterizar rápidamente el carbón. Los resultados se comparan muy bien con los de los carbones colombianos normalizados por otros métodos para mejorar la precisión de la medición. Sin embargo, el método modificado no ofreció un ajuste apropiado para el carbón de rango inferior y produjo valores de reflectancia extremadamente bajos. Este efecto posiblemente esté relacionado con la estructura molecular de la materia orgánica en el carbón o la presencia de interferencia de fluorescencia.The structural changes and the degree of maturity of three Colombian coals from the Santander and Antioquia provinces were studied using a simple and fast curve fitting method of the RBS parameters (the distance between band G and band D), FWHM - G (total width at half the maximum of the G band) and AR (area of the Raman spectrum), obtained by deconvolution and band resolution of the Micro-Raman spectra. The results were compared by morphological and chemical analysis using a SEM scanning electron microscope coupled with a solid state X - ray EDS detector. A percentage of vitrinite reflectance (% Ro) of 4.3 %, 3.8 % and 0.07 % was obtained, a percentage of carbon by EDS analysis of 91.47 %, 87.78 %, 73.4 %, a morphological description by SEM analysis presenting smooth, rough surfaces and rough-lumpy and pore size between 0.7 µm - 0.8 µm, 1.3 µm - 1.5 µm and 0.2 µm - 0.7 µm for the anthracite, semi-anthracite and bituminous samples, respectively. The results showed that based on this method, it was possible to obtain a model that allows to rapidly analyze and characterize the coal. The results compare very well to those of Colombian coals normalized by other methods to improve the precision of the measurement. The modified method, however, did not offer an appropriate fit for the lower range coal and produced extremely low reflectance values. This effect is possibly related with the molecular structure of organic matter in coal or the presence of fluorescence interference.
Evaluación de la corrosión por picado de un acero inoxidable aisi-sae 630 endurecido por precipitación en agua de mar sintética mediante técnicas eletroquÃmicas
In this research, the stainless steel AISI-SAE 630 was studied under two conditions: manufacturing condition and after a thermal treatment, with the purpose of eliminating stress possibly produced during the service time, in an environment simulating the sea water conditions, in order to analyze the behavior of this material under these conditions, during 35 days. the techniques used were spectroscopy of impedances (Eis), cyclical polarization, and differential aeration test and critical pitting temperature (cpt), in order to determine the corrosion rate by pitting, and the cpt. the results showed that the techniques of Eis and Rp are not the most adequate for measuring the corrosion rate by pitting. the test specimen without treatment presented a highest susceptibility to the pitting corrosion with Ep value smaller, which was confrmed by the profle depth, giving as a result a higher rate, probably for absence of tantalum in this material. the cpt for the stainless steel was of 29±1°c, which is very close to the temperature of service, bein this variable (temperature) the cause of the deterioration of the material. En la presente investigación se estudió el acero inoxidable AISI-SAE 630 en estado de entrega y después de un tratamiento térmico, con el fin de eliminar tensiones posiblemente producidas durante el tiempo de servicio, en un medio que simuló las condiciones del agua de mar, para conocer el comportamiento del material bajo estas condiciones, en un tiempo de treinta y cinco dÃas. se emplearon las técnicas electroquÃmicas de espectroscopia de impedancias (Eis), polarización cÃclica, y las pruebas de aireación diferencial y temperatura crÃtica de picado (cpt), con el fin de determinar la velocidad de corrosión por picado, y la cpt. Los resultados mostraron que las técnicas de EIS y Rp no son las más adecuadas para medir la velocidad de corrosión por picado. La probeta "blanco" presentó una mayor susceptibilidad a la corrosión por picado dado que el valor de Ep fue menor, además para esta probeta la profundidad de picado fue mayor, lo cual se confrmó por el perfl de profundidad, dando como resultado una velocidad de corrosión más alta, probablemente por la ausencia de ta en este material. La cpt para el acero inoxidable aisi-saE 630 fue de 29±1°c, la cual está muy cercana a la temperatura de servicio, siendo esta variable (temperatura) quien haya sido la causante del deterioro del material.
Evaluación de la corrosión por picado de un acero inoxidable aisi-sae 630 endurecido por precipitación en agua de mar sintética mediante técnicas eletroquÃmicas
En la presente investigación se estudió el acero inoxidable AISI-SAE 630 en estado de entrega y después de un tratamiento térmico, con el fin de eliminar tensiones posiblemente producidas durante el tiempo de servicio, en un medio que simuló las condiciones del agua de mar, para conocer el comportamiento del material bajo estas condiciones, en un tiempo de treinta y cinco dÃas. se emplearon las técnicas electroquÃmicas de espectroscopia de impedancias (Eis), polarización cÃclica, y las pruebas de aireación diferencial y temperatura crÃtica de picado (cpt), con el fin de determinar la velocidad de corrosión por picado, y la cpt. Los resultados mostraron que las técnicas de EIS y Rp no son las más adecuadas para medir la velocidad de corrosión por picado. La probeta "blanco" presentó una mayor susceptibilidad a la corrosión por picado dado que el valor de Ep fue menor, además para esta probeta la profundidad de picado fue mayor, lo cual se confrmó por el perfl de profundidad, dando como resultado una velocidad de corrosión más alta, probablemente por la ausencia de ta en este material. La cpt para el acero inoxidable aisi-saE 630 fue de 29±1°c, la cual está muy cercana a la temperatura de servicio, siendo esta variable (temperatura) quien haya sido la causante del deterioro del material. In this research, the stainless steel AISI-SAE 630 was studied under two conditions: manufacturing condition and after a thermal treatment, with the purpose of eliminating stress possibly produced during the service time, in an environment simulating the sea water conditions, in order to analyze the behavior of this material under these conditions, during 35 days. the techniques used were spectroscopy of impedances (Eis), cyclical polarization, and differential aeration test and critical pitting temperature (cpt), in order to determine the corrosion rate by pitting, and the cpt. the results showed that the techniques of Eis and Rp are not the most adequate for measuring the corrosion rate by pitting. the test specimen without treatment presented a highest susceptibility to the pitting corrosion with Ep value smaller, which was confrmed by the profle depth, giving as a result a higher rate, probably for absence of tantalum in this material. the cpt for the stainless steel was of 29±1°c, which is very close to the temperature of service, bein this variable (temperature) the cause of the deterioration of the material. 
Degradación de ácido poliláctico/hidroxiapatita y ácido poliglicólico en fluido corporal simulado
In this work the degradation of composites of polylactic acid, polyglycolic acid and hydroxyapatite in a simulated physiological electrolyte solution was evaluated by electrochemical quartz crystal microbalance. The materials were obtained at different concentrations and cathodically electrodeposited on piezoelectric quartz crystals to form thin films. Coated crystals were immersed for 1, 3, 5, 7 and 10 days in simulated body fluid at temperature and pH constant at each interval analysis was performed Electrochemical Impedance Spectroscopy and Quartz Crystal Microbalance that allowed to relate the frequency change of the microbalance with the total electric charge transferred in the process of degradation.El presente trabajo de investigación presenta la degradación de materiales compuestos de ácido poliláctico, ácido poliglicólico e hidroxiapatita en un electrolito de solución fisiológica simulada, fue evaluada mediante electroquÃmica y microbalanza de cristal de cuarzo. Los materiales fueron obtenidos a diferentes concentraciones y electrodepositados catódicamente sobre cristales de cuarzo piezoeléctricos para formar pelÃculas delgadas. Los cristales recubiertos fueron sumergidos durante 1, 3, 5, 7 y 10 dÃas en fluido corporal simulado a temperatura y pH constantes y en cada intervalo se realizaron análisis de espectroscopia de impedancia electroquÃmica y microbalanza de cristal de cuarzo que permitieron relacionar los cambios de frecuencia de la microbalanza con la carga eléctrica total transferida durante el proceso de degradación