12 research outputs found

    Dosimetric impact of gastrointestinal air column in radiation treatment of pancreatic cancer

    Get PDF
    OBJECTIVE: Dosimetric evaluation of air column in gastrointestinal (GI) structures in intensity modulated radiation therapy (IMRT) of pancreatic cancer. METHODS: Nine sequential patients were retrospectively chosen for dosimetric analysis of air column in the GI apparatus in pancreatic cancer using cone beam CT (CBCT). The four-dimensional CT (4DCT) was used for target and organs at risk (OARs) and non-coplanar IMRT was used for treatment. Once a week, these patients underwent CBCT for air filling, isocentre verification and dose calculations retrospectively. RESULTS: Abdominal air column variation was as great as ±80% between weekly CBCT and 4DCT. Even with such a large air column in the treatment path for pancreatic cancer, changes in anteroposterior dimension were minimal (2.8%). Using IMRT, variations in air column did not correlate dosimetrically with large changes in target volume. An average dosimetric deviation of mere -3.3% and a maximum of -5.5% was observed. CONCLUSION: CBCT revealed large air column in GI structures; however, its impact is minimal for target coverage. Because of the inherent advantage of segmentation in IMRT, where only a small fraction of a given beam passes through the air column, this technique might have an advantage over 3DCRT in treating upper GI malignancies where the daily air column can have significant impact. Advances in knowledge: Radiation treatment of pancreatic cancer has significant challenges due to positioning, imaging of soft tissues and variability of air column in bowels. The dosimetric impact of variable air column is retrospectively studied using CBCT. Even though, the volume of air column changes by ± 80%, its dosimetric impact in IMRT is minimum

    Quantifying Proton Fields for Midline Brain Tumors: A Benefit/Cost Analysis of Planning Objectives

    Get PDF
    Purpose: We sought to quantify the optimum number of beams by using a midline sagittal arrangement for midline brain tumors when considering the competing demands of a high degree of target conformation and maximizing reduction of nontarget brain dose. The volume of nontarget brain tissue receiving between 5 and 20 Gy (V5-V20) was selected to measure "low-dose bath" to normal brain. Materials and Methods: An exploratory model was developed with 6 midline brain targets created by using spheres of 1-, 3-, and 5-cm diameters located in superficial and deep locations. For each, five 3-dimensional proton treatment plans with uniform beam scanning were generated by using 1 to 5 fields. Dose-volume histograms were analyzed to calculate conformation number and V5-V20. A benefit/cost analysis was performed to determine the marginal gain in conformation number and the marginal cost of V5-V20 for the addition of each field and hypothesize the optimum number of treatment fields. We tested our hypothesis by re-planning 10 actual patient tumors with the same technique to compare the averages of these 50 plans to our model. Results: Our model and validation cohort demonstrated the largest marginal benefit in target conformation and the lowest marginal cost in normal brain V5-V20 with the addition of a second proton field. The addition of a third field resulted in a relative marginal benefit in target conformation of just 3.9% but a relative marginal cost in V5-V20 of 78.7%. Normal brain absolute V5-V20 increased in a nearly linear fashion with each additional field. Conclusions: When treating midline brain lesions with 3-dimensional proton therapy in an array of midline sagittal beams, our model suggests the most appropriate number of fields is 2. There was little marginal benefit in target conformation and increasing cost of normal brain dose when increasing the number of fields beyond this

    Does Graded Prognostic Assessment outperform Recursive Partitioning Analysis in patients with moderate prognosis brain metastases?

    Get PDF
    AIM: To compare the clinical utility of the Recursive Partitioning Analysis (RPA) and Graded Prognostic Assessment (GPA) in predicting outcomes for moderate prognosis patients with brain metastases. METHODS & MATERIALS: We reviewed 101 whole brain radiotherapy cases. RPA and GPA were calculated. Overall survival was compared. RESULTS: Sixty-eight patients had moderate prognosis. RPA patient characteristics for increased death hazard were ≤10 WBRT fractions or no surgery/radiosurgery. GPA patients had increased death risk with no surgery/radiosurgery or lower Karnofsky Performance Status. CONCLUSION: The indices have similar predicted survival. Patients scored by RPA with longer radiation schedules had longer survival; patients scored by GPA did not. This indicates GPA is more clinically useful, leaving less room for subjective treatment choices

    Forward Modeling of Space-borne Gravitational Wave Detectors

    Full text link
    Planning is underway for several space-borne gravitational wave observatories to be built in the next ten to twenty years. Realistic and efficient forward modeling will play a key role in the design and operation of these observatories. Space-borne interferometric gravitational wave detectors operate very differently from their ground based counterparts. Complex orbital motion, virtual interferometry, and finite size effects complicate the description of space-based systems, while nonlinear control systems complicate the description of ground based systems. Here we explore the forward modeling of space-based gravitational wave detectors and introduce an adiabatic approximation to the detector response that significantly extends the range of the standard low frequency approximation. The adiabatic approximation will aid in the development of data analysis techniques, and improve the modeling of astrophysical parameter extraction.Comment: 14 Pages, 14 Figures, RevTex

    DMAPT inhibits NF-κB activity and increases sensitivity of prostate cancer cells to X-rays in vitro and in tumor xenografts in vivo

    Get PDF
    Constitutive activation of the pro-survival transcription factor NF-κB has been associated with resistance to both chemotherapy and radiation therapy in many human cancers, including prostate cancer. Our lab and others have demonstrated that the natural product parthenolide can inhibit NF-κB activity and sensitize PC-3 prostate cancers cells to X-rays in vitro; however, parthenolide has poor bioavailability in vivo and therefore has little clinical utility in this regard. We show here that treatment of PC-3 and DU145 human prostate cancer cells with dimethylaminoparthenolide (DMAPT), a parthenolide derivative with increased bioavailability, inhibits constitutive and radiation-induced NF-κB binding activity and slows prostate cancer cell growth. We also show that DMAPT increases single and fractionated X-ray-induced killing of prostate cancer cells through inhibition of DNA double strand break repair and also that DMAPT-induced radiosensitization is, at least partially, dependent upon the alteration of intracellular thiol reduction-oxidation chemistry. Finally, we demonstrate that the treatment of PC-3 prostate tumor xenografts with oral DMAPT in addition to radiation therapy significantly decreases tumor growth and results in significantly smaller tumor volumes compared to xenografts treated with either DMAPT or radiation therapy alone, suggesting that DMAPT might have a potential clinical role as a radiosensitizing agent in the treatment of prostate cancer

    Predictors of Nodal and Metastatic Failure in Early Stage Non-Small Cell Lung Cancer after Stereotactic Body Radiation Therapy

    Get PDF
    Introduction/Background Many early-stage non-small cell lung cancer (ES-NSCLC) patients undergoing stereotactic body radiation therapy (SBRT) develop metastases, which is associated with poor outcomes. We sought to identify factors predictive of metastases after lung SBRT and created a risk stratification tool. Materials and Methods We included 363 patients with ES-NSCLC who received SBRT; median follow-up was 5.8 years. The following patient and tumor factors were retrospectively analyzed for their association with metastases (defined as nodal and/or distant failure): sex; age; lobe involved; centrality; previous NSCLC; smoking status; gross tumor volume (GTV); T-stage; histology; dose; minimum, maximum, and mean GTV dose; and parenchymal lung failure. A metastasis risk-score linear-model using beta coefficients from a multivariate Cox model was built. Results A total of 111/406 (27.3%) lesions metastasized. GTV volume and dose were significantly associated with metastases on univariate and multivariate Cox proportional hazards modeling (p<0.001 and HR=1.02 per mL, p<0.05 and HR=0.99 per Gy, respectively). Histology, T-stage, centrality, lung parenchymal failures, and previous NSCLC were not associated with development of metastasis. A metastasis risk-score model using GTV volume and prescription dose was built: [risk score=(0.01611 x GTV)–(0.00525 x dose (BED10))]. Two risk-score cutoffs separating the cohort into low-, medium-, and high-risk subgroups were examined. The risk-score identified significant differences in time to metastases between low-, medium-, and high-risk patients (p<0.001), with 3-year estimates of 81.1%, 63.8%, and 38%, respectively. Conclusion GTV volume and radiation dose are associated with time to metastasis and may be used to identify patients at higher risk of metastasis after lung SBRT

    A Randomized Prospective Study of Lumpectomy Margin Assessment with use of MarginProbe in Patients with Nonpalpable Breast Malignancies.

    No full text
    BACKGROUND: The presence of tumor cells at the margins of breast lumpectomy specimens is associated with an increased risk of ipsilateral tumor recurrence. Twenty to 30 % of patients undergoing breast-conserving surgery require second procedures to achieve negative margins. This study evaluated the adjunctive use of the MarginProbe device (Dune Medical Devices Ltd, Caesarea, Israel) in providing real-time intraoperative assessment of lumpectomy margins. METHODS: This multicenter randomized trial enrolled patients with nonpalpable breast malignancies. The study evaluated MarginProbe use in addition to standard intraoperative methods for margin assessment. After specimen removal and inspection, patients were randomized to device or control arms. In the device arm, MarginProbe was used to examine the main lumpectomy specimens and direct additional excision of positive margins. Intraoperative imaging was used in both arms; no intraoperative pathology assessment was permitted. RESULTS: In total, 596 patients were enrolled. False-negative rates were 24.8 and 66.1 % and false-positive rates were 53.6 and 16.6 % in the device and control arms, respectively. All positive margins on positive main specimens were resected in 62 % (101 of 163) of cases in the device arm, versus 22 % (33 of 147) in the control arm (p \u3c 0.001). A total of 19.8 % (59 of 298) of patients in the device arm underwent a reexcision procedure compared with 25.8 % (77 of 298) in the control arm (6 % absolute, 23 % relative reduction). The difference in tissue volume removed was not significant. CONCLUSIONS: Adjunctive use of the MarginProbe device during breast-conserving surgery improved surgeons\u27 ability to identify and resect positive lumpectomy margins in the absence of intraoperative pathology assessment, reducing the number of patients requiring reexcision. MarginProbe may aid performance of breast-conserving surgery by reducing the burden of reexcision procedures for patients and the health care system
    corecore