9 research outputs found

    Análisis secuencial de parámetros en evaluación de búsqueda flotante y extracción de metaclasifcadores débiles

    Get PDF
    Feature extraction is one of the most challenging tasks in the design of a classification system. In this work we present a novel floating evaluation and search algorithm focused on weak features. In classification problem with a high number of weak features an exhaustive feature selection protocol is calculation cost prohibitive, so in our approach a floating method is proposed with restricted feature subset evaluation. Our proposal considerably decreases the calculation costs of feature search compared with conventional bottom-up, top-down and floating techniques, as well with other recent techniques, without reducing the classification performance. The proposed methodology was tested for 7-class facial expression recognition and the results show the viability of the approach for multiclass problems with weak features.La extracción de parámetros es una de las tareas más exigentes en el diseño de un sistema de clasifcación. En este artículo se presenta un nuevo algoritmo de evaluación y búsqueda fotante enfocado en parámetros débiles. En problemas de clasifcación con un elevado número de parámetros débiles, un protocolo de búsqueda exhaustiva de parámetros es limitado por costos de cálculo. La propuesta reduce notablemente los costos de cálculo de la búsqueda de parámetros comparado con técnicas convencionales bottom-up, top-down y fotantes, así como otras técnicas recientes, sin reducir el desempeño del sistema de clasifcación. La metodología propuesta fue probada en un problema de reconocimiento de 7 clases de expresión facial y los resultados muestran la viabilidad del método para problemas multiclase con parámetros débiles

    Análisis secuencial de parámetros en evaluación de búsqueda flotante y extracción de metaclasifcadores débiles

    Get PDF
    Feature extraction is one of the most challenging tasks in the design of a classification system. In this work we present a novel floating evaluation and search algorithm focused on weak features. In classification problem with a high number of weak features an exhaustive feature selection protocol is calculation cost prohibitive, so in our approach a floating method is proposed with restricted feature subset evaluation. Our proposal considerably decreases the calculation costs of feature search compared with conventional bottom-up, top-down and floating techniques, as well with other recent techniques, without reducing the classification performance. The proposed methodology was tested for 7-class facial expression recognition and the results show the viability of the approach for multiclass problems with weak features.La extracción de parámetros es una de las tareas más exigentes en el diseño de un sistema de clasifcación. En este artículo se presenta un nuevo algoritmo de evaluación y búsqueda fotante enfocado en parámetros débiles. En problemas de clasifcación con un elevado número de parámetros débiles, un protocolo de búsqueda exhaustiva de parámetros es limitado por costos de cálculo. La propuesta reduce notablemente los costos de cálculo de la búsqueda de parámetros comparado con técnicas convencionales bottom-up, top-down y fotantes, así como otras técnicas recientes, sin reducir el desempeño del sistema de clasifcación. La metodología propuesta fue probada en un problema de reconocimiento de 7 clases de expresión facial y los resultados muestran la viabilidad del método para problemas multiclase con parámetros débiles

    Evaluación de desempeño del algoritmo de seguimiento de características faciales basado en modelos ASM usando Kinect

    Get PDF
    En este trabajo se presenta la evaluación del desempeño de un algoritmo de seguimiento de las características faciales, aplicando modelos de forma activa (ASM) y utilizando el sensor Kinect como dispositivo de captura de imagen. El desarrollo se realizó mediante las librerías de OpenCV, en un PC portátil con Procesador Core i5 a 2.4Ghz, 4 Gigabytes de memoria RAM, que corre bajo sistema operativo Windows 7. Para la evaluación, se ejecutó el algoritmo para observar la respuesta respecto a las distintas posturas y expresiones faciales. Se tomaron los tiempos de estabilización de los puntos sobre la imagen y se analizó punto a punto y con criterio humano la localización de los puntos sobre la imagen. Para facilitar el análisis se agrupan los puntos acordes a la zona del rostro: Contorno de la cara, cejas, nariz, ojos y boca. Por último, se presentan los resultados del tiempo promedio de ajuste del modelo, el promedio de frames, así como un error promedio de posicionamiento en las distintas condiciones del rostro, lo cual muestra la robustez de este trabajo y la adaptabilidad para trabajos futuros

    Equipo para adquisición de señales de electroconducción en el sistema nervioso periférico en humanos. Diseño y construcción

    Get PDF
    Un examen de electroconducción consiste en la medición de la velocidad de respuesta de los nerviosperiféricos, ante un estimulo eléctrico de alto voltaje y corto duración. La respuesta a este estimulopuede ser un potencial de acción nervioso sensitivo compuesto o potencial de acción nervioso motorcompuesto. Es asíquepara realizar un estudio de electroconduccián es necesario registrary visualizareste tipo de potenciales de acción. El NCV2003 es un dispositivo diseñado para este propósito,contiene un estimulador, un sensor de temperatura y un sistema de adquisición de señales. La señalcapturada se digitaliza con una resolución de 16 bits Y es llevada a un computador que visualizaresultados como la temperatura, la latencia, amplitudy velocidadde conducción nerviosa delpaciente.Con los resultados obtenidos, se genera un reporte con el cual el especialista que está realizando elestudio, puede realizar con facilidad un diagnostico del paciente.An examination of electroconduction consists of the measurement of the speed of response of the peripheral nerves, before an electric stimulation of high voltage and short duration. The response to this stimulus may be a composite or potential sensory nerve action potential or motor potential nerve action potential. It is so to perform an electroconduction study it is necessary to register and visualize the type of action potentials. The NCV2003 is a device designed for this purpose, it contains a stimulator, a temperature sensor and a signal acquisition system. The captured signal is digitized with a resolution of 16 bits AND is taken to a computer that displays results such as temperature, latency, amplitude and speed of nerve conduction of the patient. With the results obtained, a report is generated with which the specialist who is performing the study, can easily perform a patient diagnosis

    Equipo para adquisición de señales de electroconducción en el sistema nervioso periférico en humanos. Diseño y construcción

    Get PDF
    Un examen de electroconducción consiste en la medición de la velocidad de respuesta de los nerviosperiféricos, ante un estimulo eléctrico de alto voltaje y corto duración. La respuesta a este estimulopuede ser un potencial de acción nervioso sensitivo compuesto o potencial de acción nervioso motorcompuesto. Es asíquepara realizar un estudio de electroconduccián es necesario registrary visualizareste tipo de potenciales de acción. El NCV2003 es un dispositivo diseñado para este propósito,contiene un estimulador, un sensor de temperatura y un sistema de adquisición de señales. La señalcapturada se digitaliza con una resolución de 16 bits Y es llevada a un computador que visualizaresultados como la temperatura, la latencia, amplitudy velocidadde conducción nerviosa delpaciente.Con los resultados obtenidos, se genera un reporte con el cual el especialista que está realizando elestudio, puede realizar con facilidad un diagnostico del paciente.An examination of electroconduction consists of the measurement of the speed of response of the peripheral nerves, before an electric stimulation of high voltage and short duration. The response to this stimulus may be a composite or potential sensory nerve action potential or motor potential nerve action potential. It is so to perform an electroconduction study it is necessary to register and visualize the type of action potentials. The NCV2003 is a device designed for this purpose, it contains a stimulator, a temperature sensor and a signal acquisition system. The captured signal is digitized with a resolution of 16 bits AND is taken to a computer that displays results such as temperature, latency, amplitude and speed of nerve conduction of the patient. With the results obtained, a report is generated with which the specialist who is performing the study, can easily perform a patient diagnosis

    Análisis secuencial de parámetros en evaluación de búsqueda flotante y extracción de metaclasifcadores débiles

    No full text
    Feature extraction is one of the most challenging tasks in the design of a classification system. In this work we present a novel floating evaluation and search algorithm focused on weak features. In classification problem with a high number of weak features an exhaustive feature selection protocol is calculation cost prohibitive, so in our approach a floating method is proposed with restricted feature subset evaluation. Our proposal considerably decreases the calculation costs of feature search compared with conventional bottom-up, top-down and floating techniques, as well with other recent techniques, without reducing the classification performance. The proposed methodology was tested for 7-class facial expression recognition and the results show the viability of the approach for multiclass problems with weak features.La extracción de parámetros es una de las tareas más exigentes en el diseño de un sistema de clasifcación. En este artículo se presenta un nuevo algoritmo de evaluación y búsqueda fotante enfocado en parámetros débiles. En problemas de clasifcación con un elevado número de parámetros débiles, un protocolo de búsqueda exhaustiva de parámetros es limitado por costos de cálculo. La propuesta reduce notablemente los costos de cálculo de la búsqueda de parámetros comparado con técnicas convencionales bottom-up, top-down y fotantes, así como otras técnicas recientes, sin reducir el desempeño del sistema de clasifcación. La metodología propuesta fue probada en un problema de reconocimiento de 7 clases de expresión facial y los resultados muestran la viabilidad del método para problemas multiclase con parámetros débiles

    Fusión de clasificadores débiles euclidianos, FDA y SVM por a posteriori confidence classification (APCC)

    Get PDF
    Los sistemas de clasificación binario y multiclase presentan inconvenientes cuando existe traslape importante entre las clases, representación insuficiente de las clases o asimetría en la representación. Sistemas de clasificación sofisticados, incluyendo SVM (máquinas de soporte vectorial) y SVM-RBF (máquinas de soporte vectorial con funciones de base radial) pueden tener inconvenientes en la generalización de estos problemas, de manera que la obtención de una clasificación exitosa tiene inconvenientes importantes. En este trabajo se muestra cómo el uso de clasificadores por métricas más simples puede ayudar al sistema global mediante fusión de criterios usando el algoritmo APCC (A Posteriori Confidence Classification). El algoritmo APCC determina la confiabilidad individual de cada parámetro y cada sistema de clasificación y otorga ponderación a posteriori a cada clasificador en función de su salida. Los protocolos desarrollados fueron probados tanto en datos simulados como en datos reales de parámetros VPOEM y TPOEM (Volumetric Patterns of Oriented Edge Magnitudes y Temporal Patterns of Oriented Edge Magnitudes) para la representación de la expresión facial. En ambos casos el uso de APCC y fusión de clasificadores permitió incrementar significativamente la tasa de clasificación

    Equipo para adquisición de señales de electroconducción en el sistema nervioso periférico en humanos. Diseño y construcción

    No full text
    An examination of electroconduction consists of the measurement of the speed of response of the peripheral nerves, before an electric stimulation of high voltage and short duration. The response to this stimulus may be a composite or potential sensory nerve action potential or motor potential nerve action potential. It is so to perform an electroconduction study it is necessary to register and visualize the type of action potentials. The NCV2003 is a device designed for this purpose, it contains a stimulator, a temperature sensor and a signal acquisition system. The captured signal is digitized with a resolution of 16 bits AND is taken to a computer that displays results such as temperature, latency, amplitude and speed of nerve conduction of the patient. With the results obtained, a report is generated with which the specialist who is performing the study, can easily perform a patient diagnosis.Un examen de electroconducción consiste en la medición de la velocidad de respuesta de los nerviosperiféricos, ante un estimulo eléctrico de alto voltaje y corto duración. La respuesta a este estimulopuede ser un potencial de acción nervioso sensitivo compuesto o potencial de acción nervioso motorcompuesto. Es asíquepara realizar un estudio de electroconduccián es necesario registrary visualizareste tipo de potenciales de acción. El NCV2003 es un dispositivo diseñado para este propósito,contiene un estimulador, un sensor de temperatura y un sistema de adquisición de señales. La señalcapturada se digitaliza con una resolución de 16 bits Y es llevada a un computador que visualizaresultados como la temperatura, la latencia, amplitudy velocidadde conducción nerviosa delpaciente.Con los resultados obtenidos, se genera un reporte con el cual el especialista que está realizando elestudio, puede realizar con facilidad un diagnostico del paciente

    Worldwide Disparities in Recovery of Cardiac Testing 1 Year Into COVID-19

    No full text
    BACKGROUND The extent to which health care systems have adapted to the COVID-19 pandemic to provide necessary cardiac diagnostic services is unknown.OBJECTIVES The aim of this study was to determine the impact of the pandemic on cardiac testing practices, volumes and types of diagnostic services, and perceived psychological stress to health care providers worldwide.METHODS The International Atomic Energy Agency conducted a worldwide survey assessing alterations from baseline in cardiovascular diagnostic care at the pandemic's onset and 1 year later. Multivariable regression was used to determine factors associated with procedure volume recovery.RESULTS Surveys were submitted from 669 centers in 107 countries. Worldwide reduction in cardiac procedure volumes of 64% from March 2019 to April 2020 recovered by April 2021 in high- and upper middle-income countries (recovery rates of 108% and 99%) but remained depressed in lower middle- and low-income countries (46% and 30% recovery). Although stress testing was used 12% less frequently in 2021 than in 2019, coronary computed tomographic angiography was used 14% more, a trend also seen for other advanced cardiac imaging modalities (positron emission tomography and magnetic resonance; 22%-25% increases). Pandemic-related psychological stress was estimated to have affected nearly 40% of staff, impacting patient care at 78% of sites. In multivariable regression, only lower-income status and physicians' psychological stress were significant in predicting recovery of cardiac testing.CONCLUSIONS Cardiac diagnostic testing has yet to recover to prepandemic levels in lower-income countries. Worldwide, the decrease in standard stress testing is offset by greater use of advanced cardiac imaging modalities. Pandemic-related psychological stress among providers is widespread and associated with poor recovery of cardiac testing. (C) 2022 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation
    corecore