15 research outputs found

    Improved Energy Supply Regulation in Chronic Hypoxic Mouse Counteracts Hypoxia-Induced Altered Cardiac Energetics

    Get PDF
    Hypoxic states of the cardiovacular system are undoubtedly associated with the most frequent diseases of modern time. Therefore, understanding hypoxic resistance encountered after physiological adaptation such as chronic hypoxia, is crucial to better deal with hypoxic insult. In this study, we examine the role of energetic modifications induced by chronic hypoxia (CH) in the higher tolerance to oxygen deprivation.P-NMR), and to describe the integrated changes in cardiac energetics regulation by using Modular Control Analysis (MoCA). Oxygen reduction induced a concomitant decrease in RPP (−46%) and in [PCr] (−23%) in Control hearts while CH hearts energetics was unchanged. MoCA demonstrated that this adaptation to hypoxia is the direct consequence of the higher responsiveness (elasticity) of ATP production of CH hearts compared with Controls (−1.88±0.38 vs −0.89±0.41, p<0.01) measured under low oxygen perfusion. This higher elasticity induces an improved response of energy supply to cellular energy demand. The result is the conservation of a healthy control pattern of contraction in CH hearts, whereas Control hearts are severely controlled by energy supply.As suggested by the present study, the mechanisms responsible for this increase in elasticity and the consequent improved ability of CH heart metabolism to respond to oxygen deprivation could participate to limit the damages induced by hypoxia

    The structure and dynamics of M13 procoat protein membrane insertion

    No full text
    A review and discussion with 5 refs., on membrane insertion of bacteriophage M13 procoat protein, giving emphasis to structural fluctuations during assocn. with membranes. [on SciFinder (R)

    4-Amino-TEMPO loaded liposomes as sensitive EPR and OMRI probes for the detection of phospholipase A2 activity

    No full text
    Abstract This work aims at developing a diagnostic method based on Electron Paramagnetic Resonance (EPR) measurements of stable nitroxide radicals released from “EPR silent” liposomes. The liposome destabilisation and consequent radical release is enzymatically triggered by the action of phospholipase A2 (PLA2) present in the biological sample of interest. PLA2 are involved in a broad range of processes, and changes in their activity may be considered as a unique valuable biomarker for early diagnoses. The minimum amount of PLA2 measured “in vitro” was 0.09 U/mL. Moreover, the liposomes were successfully used to perform Overhauser-enhanced Magnetic Resonance Imaging (OMRI) in vitro at 0.2 T. The amount of radicals released by PLA2 driven liposome destabilization was sufficient to generate a well detectable contrast enhancement in the corresponding OMRI image

    A system for in vivo on-demand ultra-low field Overhauser-enhanced 3D-Magnetic resonance imaging

    No full text
    &lt;p&gt;Development of very-low field MRI is an active area of research. It aims at reducing operating costs and improve portability. However, the signal-to-noise issue becomes prominent at ultra-low field (&lt;1 mT), especially for molecular imaging purposes that addresses specific biochemical events. In the context of preclinical molecular MRI of abnormal proteolysis the paper describes a MRI system able to produce Overhauser-enhanced MR images in living rats through in situ Dynamic Nuclear Polarization at 206 ÎŒT using stable and non-toxic nitroxides. In parallel conventional images are generated at 206 ÎŒT following pre-polarization at 20 mT. Results show that nitroxides are visualized in 3D within a few minutes in the lungs, kidneys and bladder post-administration. This system will be used for molecular imaging of inflammation using protease-specific nitroxide probes.&lt;/p&gt

    J Magn Reson

    No full text
    Development of very-low field MRI is an active area of research. It aims at reducing operating costs and improve portability. However, the signal-to-noise issue becomes prominent at ultra-low field (<1 mT), especially for molecular imaging purposes that addresses specific biochemical events. In the context of preclinical molecular MRI of abnormal proteolysis the paper describes a MRI system able to produce Overhauser-enhanced MR images in living rats through in situ Dynamic Nuclear Polarization at 206 ”T using stable and non-toxic nitroxides. In parallel conventional images are generated at 206 ”T following pre-polarization at 20 mT. Results show that nitroxides are visualized in 3D within a few minutes in the lungs, kidneys and bladder post-administration. This system will be used for molecular imaging of inflammation using protease-specific nitroxide probes

    Study of the MR relaxation of microglia cells labeled with Gd-DTPA-bearing nanoparticles.

    No full text
    Therapies involving cells as vehicles need to visualize in situ the trafficking of the cells concerned. This cellular imaging can be driven by cell contrast agent-based nanoparticle internalization and non-invasive MRI (magnetic resonance imaging) detection. Here, microglial cells, that would transport a suicide gene to a glioma, were incubated for different times, with various concentrations of silica nanoparticles on which numerous Gd-DTPA were grafted. The goal of this study was to investigate the repartition of cell-associated particles. MRI was used to quantitatively follow the particle uptake process. Fluorescence microscopy images showed that, although most of the nanoparticles were internalized, some remained adsorbed on the extracellular membrane surface. The cells were then submitted to various treatments: glycine to release bound nanoparticles and/or ultrasound to destroy the cell membranes. The R(1) relaxation rates were measured at 4.7 T. R(1) was maximal for 4 h of incubation, decreased after 8 h and remained stable for the 24 following hours. The magnetic resonance signal of ultrasonicated and glycine-treated cells made it possible to quantify the loss of bound nanoparticles after 8 h. Nevertheless, this release did not prevent cell detection since the internalized nanoparticles are enough concentrated to visualize the labeled cells even after 4 days of cell growth. These results highlight the compartmentalization of nanoparticles in microglia and the evolution of the MR signal of the labeled cells. This study could be of importance to interpret in vivo the MR signal changes that could occur after administration of such nanoparticle-labeled cells in therapeutic strategies

    beta-Phosphorus hyperfine coupling constant in nitroxides: 5. Solvent effect

    No full text
    International audienceRecently, we published the titration of water in organic solvents and conversely using this family of nitroxides (Org. Biomol. Chem. 2015 ASAP). In this article, we show that the a(beta,P) of persistent cyclic beta-phosphorylated nitroxides decreases with the normalized polarity Reichardt's constant E-T(N). Koppel-Palm and Kalmet-Abboud-Taft relationships were applied to get a deeper insight into the effects influencing a(N) and a(beta,P): polarity/polarizability, hydrogen bond donor property, and structuredness of the cybotactic region

    Magnetic Resonance Imaging of Protease-Mediated Lung Tissue Inflammation and Injury

    No full text
    Pulmonary inflammation usually involves strong neutrophil recruitment with a marked release of proteases such as neutrophil elastase (NE). Noninvasive in vivo assessment of unregulated elastase activity in the lungs would provide a valuable diagnostic tool. Here, it is proposed to use Overhauser-enhanced magnetic resonance imaging (OMRI) in mice where inflammation was induced by the instillation of lipopolysaccharide (LPS). OMRI contrast in the lungs was generated by a dedicated NE free radical substrate. The free radical decayed more rapidly in LPS-treated mouse lungs than in control mice, indicating the occurrence of increased proteolysis under inflammation. Preclinical detection of abnormal proteolysis opens the way for new diagnosis modality and antiprotease testing in vivo
    corecore