536 research outputs found

    A new displacement-based approach to calculate stress intensity factors with the boundary element method

    Get PDF
    The analysis of cracked brittle mechanical components considering linear elastic fracture mechanics is usually reduced to the evaluation of stress intensity factors (SIFs). The SIF calculation can be carried out experimentally, theoretically or numerically. Each methodology has its own advantages but the use of numerical methods has be-come very popular. Several schemes for numerical SIF calculations have been developed, the J-integral method being one of the most widely used because of its energy-like formulation. Additionally, some variations of the J-integral method, such as displacement-based methods, are also becoming popular due to their simplicity. In this work, a simple displacement-based scheme is proposed to calculate SIFs, and its performance is compared with contour integrals. These schemes are all implemented with the Boundary Element Method (BEM) in order to exploit its advantages in crack growth modelling. Some simple examples are solved with the BEM and the calculated SIF values are compared against available solutions, showing good agreement between the different schemes

    Continuum corrections to the level density and its dependence on excitation energy, n-p asymmetry, and deformation

    Full text link
    In the independent-particle model, the nuclear level density is determined from the neutron and proton single-particle level densities. The single-particle level density for the positive-energy continuum levels is important at high excitation energies for stable nuclei and at all excitation energies for nuclei near the drip lines. This single-particle level density is subdivided into compound-nucleus and gas components. Two methods were considered for this subdivision. First in the subtraction method, the single-particle level density is determined from the scattering phase shifts. In the Gamov method, only the narrow Gamov states or resonances are included. The level densities calculated with these two methods are similar, both can be approximated by the backshifted Fermi-gas expression with level-density parameters that are dependent on A, but with very little dependence on the neutron or proton richness of the nucleus. However, a small decrease in the level-density parameter was predicted for some nuclei very close to the drip lines. The largest difference between the calculations using the two methods was the deformation dependence on the level density. The Gamov method predicts a very strong peaking of the level density at sphericity for high excitation energies. This leads to a suppression of deformed configurations and, consequently, the fission rate predicted by the statistical model is reduced in the Gamov method.Comment: 18 pages 24 figure

    Detection of osteomyelitis in the diabetic foot by imaging techniques. A systematic review and meta-analysis comparing mri, white blood cell scintigraphy, and FDG-PET

    Get PDF
    OBJECTIVE Diagnosing bone infection in the diabetic foot is challenging and often requires several diagnostic procedures, including advanced imaging. We compared the diagnostic performances of MRI, radiolabeled white blood cell (WBC) scintigraphy (either with 99mTc-hexamethylpropyleneamineoxime [HMPAO] or 111In-oxine), and [18F]fluorodeoxyglucose positron emission tomography (18F-FDG-PET)/ computed tomography. RESEARCH DESIGN AND METHODS We searchedMedline andEmbase as of August 2016 for studies of diagnostic tests on patients known or suspected to have diabetes and a foot infection. We performed a systematic review using criteria recommended by the Cochrane Review of a database that included prospective and retrospective diagnostic studies performed on patients with diabetes in whom there was a clinical suspicion of osteomyelitis of the foot. The preferred reference standard was bone biopsy and subsequent pathological (or microbiological) examination. RESULTS Our review found 6,649 articles; 3,894 in Medline and 2,755 in Embase. A total of 27 full articles and 2 posters was selected for inclusion in the analysis. The performance characteristics for the 18F-FDG-PET were: sensitivity, 89%; specificity, 92%; diagnostic odds ratio (DOR), 95; positive likelihood ratio (LR), 11; and negative LR, 0.11. For WBC scan with 111In-oxine, the values were: sensitivity, 92%; specificity, 75%; DOR, 34; positive LR, 3.6; and negative LR, 0.1. For WBC scan with 99mTc-HMPAO, the values were: sensitivity, 91%; specificity, 92%; DOR, 118; positive LR, 12; and negative LR, 0.1. Finally, forMRI, the valueswere: sensitivity, 93%; specificity, 75%; DOR, 37; positive LR, 3.66, and negative LR, 0.10. CONCLUSIONS The various modalities have similar sensitivity, but 18F-FDG-PET and 99mTc-HMPAO-labeled WBC scintigraphy offer the highest specificity. Larger prospective studies with a direct comparison among the different imaging techniques are required

    Procedural recommendations of cardiac PET/CT imaging: standardization in inflammatory-, infective-, infiltrative-, and innervation (4Is)-related cardiovascular diseases: a joint collaboration of the EACVI and the EANM

    Get PDF
    With this document, we provide a standard for PET/(diagnostic) CT imaging procedures in cardiovascular diseases that are inflammatory, infective, infiltrative, or associated with dysfunctional innervation (4Is). This standard should be applied in clinical practice and integrated in clinical (multicenter) trials for optimal procedural standardization. A major focus is put on procedures using [18F]FDG, but 4Is PET radiopharmaceuticals beyond [18F]FDG are also described in this document. Whilst these novel tracers are currently mainly applied in early clinical trials, some multicenter trials are underway and we foresee in the near future their use in clinical care and inclusion in the clinical guidelines. Finally, PET/MR applications in 4Is cardiovascular diseases are also briefly described. Diagnosis and management of 4Is-related cardiovascular diseases are generally complex and often require a multidisciplinary approach by a team of experts. The new standards described herein should be applied when using PET/CT and PET/MR, within a multimodality imaging framework both in clinical practice and in clinical trials for 4Is cardiovascular indications

    Relationship between 18F-FDG Uptake in the Oral Cavity, Recent Dental Treatments, and Oral Inflammation or Infection: A Retrospective Study of Patients with Suspected Endocarditis

    Get PDF
    [18F]-fluorodeoxyglucose positron emission tomography ([18F]FDG PET/CT) has proven to be a useful diagnostic tool in patients with suspected infective endocarditis (IE), but is conflicting in relation to dental procedures. Questions: Is there a correlation between [18F]FDG PET/CT findings, recent dental treatment, and an affected oral cavity? (2) Is there a correlation between infective endocarditis (IE), oral health status, and (extra)cardiac findings on [18F]FDG PET/CT? Methods: This retrospective study included 52 patients. All [18F]FDG PET/CT scans were examined visually by pattern recognition using a three-point scale and semi-quantified within the volume of interest (VOI) using SUVmax. Results: 19 patients were diagnosed with IE (group 1), 14 with possible IE (group 2), and 19 without IE based on the modified Duke criteria (group 3). No correlation was found between visual PET and SUVmax and sites of oral inflammation and infection. The visual PET scores and SUVmax were not significantly different between all groups. A significant difference in the SUVmax of the valve between all groups was observed. Conclusions: This study suggests that no correlation exists between the PET findings in the oral cavity and dental treatments or inflammation/infection. No correlation between IE, actual oral health status, and extra-cardiac findings was demonstrated. Additional research is needed to conclude whether [18F]FDG PET/CT imaging is a reliable diagnostic modality for oral inflammation and infection sites

    A Measurement of the Ds+ Lifetime

    Full text link
    A high statistics measurement of the Ds+ lifetime from the Fermilab fixed-target FOCUS photoproduction experiment is presented. We describe the analysis of the two decay modes, Ds+ -> phi(1020)pi+ and Ds+ -> \bar{K}*(892)0K+, used for the measurement. The measured lifetime is 507.4 +/- 5.5 (stat.) +/- 5.1 (syst.) fs using 8961 +/- 105 Ds+ -> phi(1020)pi+ and 4680 +/- 90 Ds+ -> \bar{K}*(892)0K+ decays. This is a significant improvement over the present world average.Comment: 5 pages, 3 figures, 2 tables, submitted to PR

    Measurement of the D+ and Ds+ decays into K+K-K+

    Full text link
    We present the first clear observation of the doubly Cabibbo suppressed decay D+ --> K-K+K+ and the first observation of the singly Cabibbo suppressed decay Ds+ --> K-K+K+. These signals have been obtained by analyzing the high statistics sample of photoproduced charm particles of the FOCUS(E831) experiment at Fermilab. We measure the following relative branching ratios: Gamma(D+ --> K-K+K+)/Gamma(D+ --> K-pi+pi+) = (9.49 +/- 2.17(statistical) +/- 0.22(systematic))x10^-4 and Gamma(Ds+ --> K-K+K+)/Gamma(Ds+ --> K-K+pi+) = (8.95 +/- 2.12(statistical) +2.24(syst.) -2.31(syst.))x10^-3.Comment: 10 pages, 8 figure
    • …
    corecore