49 research outputs found

    Quantifying uncertainty in the measurement of arsenic in suspended particulate matter by Atomic Absorption Spectrometry with hydride generator

    Get PDF
    Arsenic is the toxic element, which creates several problems in human being specially when inhaled through air. So the accurate and precise measurement of arsenic in suspended particulate matter (SPM) is of prime importance as it gives information about the level of toxicity in the environment, and preventive measures could be taken in the effective areas. Quality assurance is equally important in the measurement of arsenic in SPM samples before making any decision. The quality and reliability of the data of such volatile elements depends upon the measurement of uncertainty of each step involved from sampling to analysis. The analytical results quantifying uncertainty gives a measure of the confidence level of the concerned laboratory. So the main objective of this study was to determine arsenic content in SPM samples with uncertainty budget and to find out various potential sources of uncertainty, which affects the results. Keeping these facts, we have selected seven diverse sites of Delhi (National Capital of India) for quantification of arsenic content in SPM samples with uncertainty budget following sampling by HVS to analysis by Atomic Absorption Spectrometer-Hydride Generator (AAS-HG). In the measurement of arsenic in SPM samples so many steps are involved from sampling to final result and we have considered various potential sources of uncertainties. The calculation of uncertainty is based on ISO/IEC17025: 2005 document and EURACHEM guideline. It has been found that the final results mostly depend on the uncertainty in measurement mainly due to repeatability, final volume prepared for analysis, weighing balance and sampling by HVS. After the analysis of data of seven diverse sites of Delhi, it has been concluded that during the period from 31st Jan. 2008 to 7th Feb. 2008 the arsenic concentration varies from 1.44 ± 0.25 to 5.58 ± 0.55 ng/m3 with 95% confidence level (k = 2)

    Phthalate Diesters and Their Metabolites in Human Breast Milk, Blood or Serum, and Urine as Biomarkers of Exposure in Vulnerable Populations

    Get PDF
    BACKGROUND: Phthalates may pose a risk for perinatal developmental effects. An important question relates to the choice of suitable biological matrices for assessing exposure during this period. OBJECTIVES: This study was designed to measure the concentrations of phthalate diesters or their metabolites in breast milk, blood or serum, and urine and to evaluate their suitability for assessing perinatal exposure to phthalates. METHODS: In 2001, 2-3 weeks after delivery, 42 Swedish primipara provided breast milk, blood, and urine samples at home. Special care was taken to minimize contamination with phthalates (e.g., use of a special breast milk pump, heat treatment of glassware and needles, addition of phosphoric acid). RESULTS: Phthalate diesters and metabolites in milk and blood or serum, if detected, were present at concentrations close to the limit of detection. By contrast, most phthalate metabolites were detectable in urine at concentrations comparable to those from the general population in the United States and in Germany. No correlations existed between urine concentrations and those found in milk or blood/serum for single phthalate metabolites. Our data are at odds with a previous study documenting frequent detection and comparatively high concentrations of phthalate metabolites in Finnish and Danish mothers' milk. CONCLUSIONS: Concentrations of phthalate metabolites in urine are more informative than those in milk or serum. Furthermore, collection of milk or blood may be associated with discomfort and potential technical problems such as contamination (unless oxidative metabolites are measured). Although urine is a suitable matrix for health-related phthalate monitoring, urinary concentrations in nursing mothers cannot be used to estimate exposure to phthalates through milk ingestion by breast-fed infants

    Carbon nanoparticles in lateral flow methods to detect genes encoding virulence factors of Shiga toxin-producing Escherichia coli

    Get PDF
    The use of carbon nanoparticles is shown for the detection and identification of different Shiga toxin-producing Escherichia coli virulence factors (vt1, vt2, eae and ehxA) and a 16S control (specific for E. coli) based on the use of lateral flow strips (nucleic acid lateral flow immunoassay, NALFIA). Prior to the detection with NALFIA, a rapid amplification method with tagged primers was applied. In the evaluation of the optimised NALFIA strips, no cross-reactivity was found for any of the antibodies used. The limit of detection was higher than for quantitative PCR (q-PCR), in most cases between 104 and 105 colony forming units/mL or 0.1–0.9 ng/ÎŒL DNA. NALFIA strips were applied to 48 isolates from cattle faeces, and results were compared to those achieved by q-PCR. E. coli virulence factors identified by NALFIA were in very good agreement with those observed in q-PCR, showing in most cases sensitivity and specificity values of 1.0 and an almost perfect agreement between both methods (kappa coefficient larger than 0.9). The results demonstrate that the screening method developed is reliable, cost-effective and user-friendly, and that the procedure is fast as the total time required is <1 h, which includes amplification

    Evaluation of Uncertainty in Analytical Measurement

    No full text

    Statistical Considerations

    No full text
    corecore