23,867 research outputs found

    Dynamic characteristics of far-field radiation of current modulated phase-locked diode laser arrays

    Get PDF
    A versatile and powerful streak camera/frame grabber system for studying the evolution of the near and far field radiation patterns of diode lasers was assembled and tested. Software needed to analyze and display the data acquired with the steak camera/frame grabber system was written and the total package used to record and perform preliminary analyses on the behavior of two types of laser, a ten emitter gain guided array and a flared waveguide Y-coupled array. Examples of the information which can be gathered with this system are presented

    An isolated epizootic of hemorrhagic-like fever in cats caused by a novel and highly virulent strain of feline calicivirus.

    Get PDF
    An isolated epizootic of a highly fatal feline calicivirus (FCV) infection, manifested in its severest form by a systemic hemorrhagic-like fever, occurred over a 1-month period among six cats owned by two different employees and a client of a private veterinary practice. The infection may have started with an unowned shelter kitten that was hospitalized during this same period for a severe atypical upper respiratory infection. The causative agent was isolated from blood and nasal swabs from two cats; the electron microscopic appearance was typical for FCV and capsid gene sequencing showed it to be genetically similar to other less pathogenic field strains. An identical disease syndrome was recreated in laboratory cats through oral inoculation with tissue culture grown virus. During the course of transmission studies in experimental cats, the agent was inadvertently spread by caretakers to an adjoining room containing a group of four normal adult cats. One of the four older cats was found dead and a second was moribund within 48-72h in spite of symptomatic treatment; lesions in these animals were similar to those of the field cats but with the added feature of severe pancreatitis. The mortality in field cats, deliberately infected laboratory cats, and inadvertently infected laboratory cats ranged from 33-50%. This new isolate of calicivirus, named FCV-Ari, was neutralized at negligible to low titer by antiserum against the universal FCV-F9 vaccine strain. Cats orally immunized with FCV-F9, and then challenge-exposed shortly thereafter with FCV-Ari, developed a milder self-limiting form of disease, indicating partial protection. However, all of the field cats, including the three that died, had been previously immunized with parenteral FCV-F9 vaccine. FCV-Ari caused a disease that was reminiscent of Rabbit Hemorrhagic Disease, a highly fatal calicivirus infection of older rabbits

    A Radon Progeny Deposition Model

    Full text link
    The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly Rn-222) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of Pb-210 on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.Comment: Proceedings of the Topical Workshop in Low Radioactivity Techniques, (Sudbury, Canada) August 28-29, 201

    Surface Partition of Large Fragments

    Full text link
    The surface partition of large fragments is derived analytically within a simple statistical model by the Laplace-Fourier transformation method. In the limit of small amplitude deformations, a suggested Hills and Dales Model reproduces the leading term of the famous Fisher result for the surface entropy with an accuracy of a few percent. The surface partition of finite fragments is discussed as well.Comment: 4 pages, 1 figur

    Electrical properties of a-antimony selenide

    Full text link
    This paper reports conduction mechanism in a-\sbse over a wide range of temperature (238K to 338K) and frequency (5Hz to 100kHz). The d.c. conductivity measured as a function of temperature shows semiconducting behaviour with activation energy Δ\DeltaE= 0.42 eV. Thermally induced changes in the electrical and dielectric properties of a-\sbse have been examined. The a.c. conductivity in the material has been explained using modified CBH model. The band conduction and single polaron hopping is dominant above room temperature. However, in the lower temperature range the bipolaron hopping dominates.Comment: 9 pages (RevTeX, LaTeX2e), 9 psfigures, also at http://pu.chd.nic.in/ftp/pub/san16 e-mail: gautam%[email protected]

    Results of On-Orbit Testing of an Extra-Vehicular Infrared Camera Inspection System

    Get PDF
    This paper will discuss an infrared camera inspection system that has been developed to allow astronauts to demonstrate the ability to inspect reinforced carbon-carbon (RCC) components on the space shuttle as part of extra-vehicular activities (EVA) while in orbit. Presented will be the performance of the EVA camera system coupled with solar heating for inspection of damaged RCC specimens and NDE standards. The data presented was acquired during space shuttle flights STS-121 and STS-115 as well during a staged EVA from the ISS. The EVA camera system was able to detect flatbottom holes as small as 2.54cm in diameter with 25% material loss. Results obtained are shown to be comparable to ground-based thermal inspections performed in the laboratory using the same camera and simulated solar heating. Data on both the time history of the specimen temperature and the ability of the inspection system to image defects due to impact will likewise be presented
    corecore