21 research outputs found

    Próteses parciais fixas reforçadas por fibras: um estudo clínico retrospectivo preliminar

    Get PDF
    The aim of this study was to evaluate the clinical performance (retention rate) of fiber-reinforced composite fixed partial dentures (FPDs). Polyethylene fiber (Ribbond®) was used combined with restorative composite during FPDs fabrication. FPDs were placed in thirteen patients in a private clinic. Nineteen FPDs were evaluated. The prosthetic space was filled with only one pontic using extracted teeth (2 cases), acrylic resin teeth (11 cases), or with composite resin (6 cases), combined with Polyethylene fiber. The clinical criterion used was based on retention rate of FPDs. If FPDs were in function in the mouth at the time of examination without previous repair they were classified as Complete Survival (CS) restorations. A classification of Survival with Rebonding (SR) was assigned in the event of an adhesive failure, but after rebonding the FPD still remained under evaluation. Treatment was classified as a Failure (F) if the FPD restoration was lost. The time of evaluation was 41.15 months (±15.13). The FPDs evaluated were retained (CS=94.75%), and no failure was found except for in one situation which required rebonding (SR=5.25%). According to the survival estimation method of Kaplan-Meyer the mean survival time was 42.3 months. At the time of evaluation investigated, polyethylene-reinforced FPDs showed a favorable retention rate in preliminary data.O objetivo deste estudo foi avaliar a performance clínica (percentagem de retenção) de próteses parciais fixas reforçadas por fibras. Fibras de polietileno (Ribbond®) foram usadas em combinação com resina composta durante a confecção das próteses. Os tratamentos foram realizadas em 13 pacientes, em uma clínica privada., sendo que 19 próteses foram reavaliadas. O espaço protético era preenchido com um pôntico usando o próprio dente extraído (2 casos), dentes de acrílico (11 casos) ou confeccionados com resina composta (6 casos), em todas as situações eram empregadas fibras de polietileno. Os critérios clínicos usados foram baseados na percentagem de retenção das próteses parciais fixas. As próteses que estavam em função no momento da avaliação, sem nunca necessitar de qualquer reparo prévio, foram classificadas como sobrevivência completa (SC). A classificação de sobrevivência com nova colagem (SR) foi utilizada para os casos de falha adesiva, com posterior cimentação da peça, a qual permanecia em função. O tratamento era classificado como falha (F) quando a restauração era perdida. O tempo médio de avaliação foi de 41,15 meses (±15,13). Nenhum caso de falha foi detectado, em apenas um caso houve falha adesiva com posterior colagem da peça (SR=5,25%) e em 94.75% dos casos as próteses permaneciam em função.. De acordo com o método de sobrevida de Kaplan-Meyer o tempo médio de sobrevida foi de 42,3 meses. As próteses parciais fixas reforçadas por fibras mostraram uma percentagem de retenção favorável neste estudo preliminar

    Fibre-reinforced composites in restorative dentistry

    No full text
    Restorative dentistry is constantly evolving as a result of innovative treatment solutions based on new materials, treatment techniques and technologies, with composite materials being a prime example. The advent of fibre reinforcement has further increased the potential uses of composites within restorative dentistry. This paper discusses fibre types, structure and the physical properties of fibre-reinforced composites, in addition to outlining some of the potential clinical applications of this exciting group of materials, thus updating the reader on the new treatment possibilities offered by these developments. </jats:p

    Effects of plasma on polyethylene fiber surface for prosthodontic application

    No full text
    ABSTRACT Plasma technology has the potential to improve the adherence of fibers to polymeric matrices, and there are prospects for its application in dentistry to reinforce the dental particulate composite. Objectives This study aimed to investigate the effect of oxygen or argon plasma treatment on polyethylene fibers. Material and Methods Connect, Construct, InFibra, and InFibra treated with oxygen or argon plasma were topographically evaluated by scanning electron microscopy (SEM), and chemically by X-ray photoelectron spectroscopy (XPS). For bending analysis, one indirect composite (Signum) was reinforced with polyethylene fiber (Connect, Construct, or InFibra). The InFibra fiber was subjected to three different treatments: (1) single application of silane, (2) oxygen or argon plasma for 1 or 3 min, (3) oxygen or argon plasma and subsequent application of silane. The samples (25x2x2 mm), 6 unreinforced and 60 reinforced with fibers, were subjected to three-point loading tests to obtain their flexural strength and deflection. The results were statistically analyzed with ANOVA and the Bonferroni correction for multiple comparison tests. Results SEM analysis showed that oxygen and argon plasma treatments promote roughness on the polyethylene fiber surface. X-ray photoelectron spectroscopy (XPS) analysis shows that both plasmas were effective in incorporating oxygenated functional groups. Argon or oxygen plasma treatment affected the flexural strength and deflection of a fiber reinforced composite. The application of silane does not promote an increase in the flexural strength of the reinforced composites. Conclusions Oxygen and argon plasma treatments were effective in incorporating oxygenated functional groups and surface roughness. The highest strength values were obtained in the group reinforced with polyethylene fibers treated with oxygen plasma for 3 min
    corecore