6 research outputs found

    Efficient extraction of vaccines formulated in aluminum hydroxide gel by including surfactants in the extraction buffer

    No full text
    Efficient antigen extraction from vaccines formulated on aluminum hydroxide gels is a critical step for the evaluation of the quality of vaccines following formulation. It has been shown in our laboratory that the efficiency of antigen extraction from vaccines formulated on Alhydrogel decreased significantly with increased storage time. To increase antigen extraction efficiency, the present study determined the effect of surfactants on antigen recovery from vaccine formulations. The Plasmodium falciparum apical membrane antigen 1 (AMA1) formulated on Alhydrogel and stored at 2-8 °C for three years was used as a model in this study. The AMA1 on Alhydrogel was extracted in the presence or absence of 30 mM sodium dodecyl sulfate (SDS) or 20 mM cetylpyridinium chloride in the extraction buffer (0.60 M citrate, 0.55 M phosphate, pH 8.5) using our standard antigen extraction protocols. Extracted AMA1 antigen was analyzed by 4-20% Tris-glycine SDS-PAGE followed by silver staining or western blotting. The results showed that inclusion of SDS or cetylpyridinium chloride in extraction buffer increased the antigen recovery dramatically and can be used for efficient characterization of Alhydrogel vaccines

    Mouse BAC Ends Quality Assessment and Sequence Analyses

    No full text
    A large-scale BAC end-sequencing project at The Institute for Genomic Research (TIGR) has generated one of the most extensive sets of sequence markers for the mouse genome to date. With a sequencing success rate of >80%, an average read length of 485 bp, and ABI3700 capillary sequencers, we have generated 449,234 nonredundant mouse BAC end sequences (mBESs) with 218 Mb total from 257,318 clones from libraries RPCI-23 and RPCI-24, representing 15× clone coverage, 7% sequence coverage, and a marker every 7 kb across the genome. A total of 191,916 BACs have sequences from both ends providing 12× genome coverage. The average Q20 length is 406 bp and 84% of the bases have phred quality scores ≥ 20. RPCI-24 mBESs have more Q20 bases and longer reads on average than RPCI-23 sequences. ABI3700 sequencers and the sample tracking system ensure that > 95% of mBESs are associated with the right clone identifiers. We have found that a significant fraction of mBESs contains L1 repeats and ∼48% of the clones have both ends with ≥ 100 bp contiguous unique Q20 bases. About 3% mBESs match ESTs and > 70% of matches were conserved between the mouse and the human or the rat. Approximately 0.1% mBESs contain STSs. About 0.2% mBESs match human finished sequences and > 70% of these sequences have EST hits. The analyses indicate that our high-quality mouse BAC end sequences will be a valuable resource to the community

    A physical map of the mouse genome

    No full text

    A physical map of the mouse genome

    No full text
    corecore