13 research outputs found

    Factors associated with coronary heart disease in COPD patients and controls

    Get PDF
    Background: COPD and coronary heart disease (CHD) frequently co-occur, yet which COPD phenotypes are most prone to CHD is poorly understood. The aim of this study was to see whether COPD patients did have a true higher risk for CHD than subjects without COPD, and to examine a range of potential factors associated with CHD in COPD patients and controls. Methods: 347 COPD patients and 428 non-COPD controls, were invited for coronary computed tomography angiography (CCTA) and pulmonary CT. Arterial blood gas, bioelectrical impedance and lung function was measured, and a detailed medical history taken. The CCTA was evaluated for significant coronary stenosis and calcium score (CaSc), and emphysema defined as >10% of total area <-950 Hounsfield units. Results: 12.6% of the COPD patients and 5.7% of the controls had coronary stenosis (p100 compared to 31.6% of the controls (p100 was 1.68 (1.12–2.53) in COPD patients compared with controls. Examining the risk of significant stenosis and CaSc>100 among COPD patients, no variable was associated with significant stenosis, whereas male sex [OR 2.85 (1.56–5.21)], age [OR 3.74 (2.42–5.77)], statin use [OR 2.23 (1.23–4.50)] were associated with CaSc>100, after adjusting for body composition, pack-years, C-reactive protein, use of angiotensin converting enzyme (ACE) inhibitors or angiotensin receptor blockers (ARBs), diabetes, emphysema score, GOLD category, exacerbation frequency, eosinophilia, and hypoxemia. Conclusion: COPD patients were more likely to have CHD, but neither emphysema score, lung function, exacerbation frequency, nor hypoxemia predicted presence of either coronary stenosis or CaSc>100.publishedVersio

    Complications and discomfort after research bronchoscopy in the MicroCOPD study

    Get PDF
    Background: Data on discomfort and complications from research bronchoscopy in chronic obstructive pulmonary disease (COPD) and asthma is limited. We present complications and discomfort occurring within a week after bronchoscopy, and investigate personal and procedural risk factors. Methods: 239 subjects with COPD, asthma or without lung disease underwent research bronchoscopies as part of a microbiome study of the lower airways (the MicroCOPD study). Bronchoscopy was done in the supine position with oral scope insertion with the option of light conscious alfentanil sedation. Sampling consisted of protected specimen brushes, bronchoalveolar lavage, small volume lavage and for some, endobronchial biopsies. Bleeding, desaturation, cough, haemodynamic changes, dyspnoea and other events that required an unplanned intervention or early termination of bronchoscopy were prospectively recorded. Follow-up consisted of a telephone interview where subjects rated discomfort and answered questions about fever sensation and respiratory symptoms in the week following bronchoscopy. Results: An unplanned intervention or early termination of bronchoscopy was required in 25.9% of bronchoscopies. Three subjects (1.3%) experienced potentially severe complications, of which all recovered without sequelae. COPD subjects experienced more dyspnoea than controls. Sedation and lower age was associated with less unplanned intervention or premature termination. About half of the subjects (47.7%) reported fever. Discomfort was associated with postprocedural fever, dread of bronchoscopy, higher score on the COPD Assessment Test and never-smoking. In subjects undergoing more than one bronchoscopy, the first bronchoscopy was often predictive for complications and postprocedural fever in the repeated bronchoscopy. Conclusion: Research bronchoscopies were not associated with more complications or discomfort in COPD subjects. 47.7% experienced postbronchoscopy fever sensation, which was associated with discomfort.publishedVersio

    Protected sampling is preferable in bronchoscopic studies of the airway microbiome

    Get PDF
    The aim was to evaluate susceptibility of oropharyngeal contamination with various bronchoscopic sampling techniques. 67 patients with obstructive lung disease and 58 control subjects underwent bronchoscopy with small-volume lavage (SVL) through the working channel, protected bronchoalveolar lavage (PBAL) and bilateral protected specimen brush (PSB) sampling. Subjects also provided an oral wash (OW) sample, and negative control samples were gathered for each bronchoscopy procedure. DNA encoding bacterial 16S ribosomal RNA was sequenced and bioinformatically processed to cluster into operational taxonomic units (OTU), assign taxonomy and obtain measures of diversity. The proportion of Proteobacteria increased, whereas Firmicutes diminished in the order OW, SVL, PBAL, PSB (p<0.01). The alpha-diversity decreased in the same order (p<0.01). Also, beta-diversity varied by sampling method (p<0.01), and visualisation of principal coordinates analyses indicated that differences in diversity were smaller between OW and SVL and OW and PBAL samples than for OW and the PSB samples. The order of sampling (left versus right first) did not influence alpha- or beta-diversity for PSB samples. Studies of the airway microbiota need to address the potential for oropharyngeal contamination, and protected sampling might represent an acceptable measure to minimise this problem.publishedVersio

    Cohort Profile: Burden of Obstructive Lung Disease (BOLD) study

    Get PDF
    The Burden of Obstructive Lung Disease (BOLD) study was established to assess the prevalence of chronic airflow obstruction, a key characteristic of chronic obstructive pulmonary disease, and its risk factors in adults (≥40 years) from general populations across the world. The baseline study was conducted between 2003 and 2016, in 41 sites across Africa, Asia, Europe, North America, the Caribbean and Oceania, and collected high-quality pre- and post-bronchodilator spirometry from 28 828 participants. The follow-up study was conducted between 2019 and 2021, in 18 sites across Africa, Asia, Europe and the Caribbean. At baseline, there were in these sites 12 502 participants with high-quality spirometry. A total of 6452 were followed up, with 5936 completing the study core questionnaire. Of these, 4044 also provided high-quality pre- and post-bronchodilator spirometry. On both occasions, the core questionnaire covered information on respiratory symptoms, doctor diagnoses, health care use, medication use and ealth status, as well as potential risk factors. Information on occupation, environmental exposures and diet was also collected

    Drengenes_LaboratoryContamination_DRYAD_Metadata

    No full text
    Metadata file needed to rerun the bioinformatics analyses performed in Laboratory Contamination in Airway Microbiome Studies

    Laboratory contamination in airway microbiome studies

    No full text
    Background The low bacterial load in samples acquired from the lungs, have made studies on the airway microbiome vulnerable to contamination from bacterial DNA introduced during sampling and laboratory processing. We have examined the impact of laboratory contamination on samples collected from the lower airways by protected (through a sterile catheter) bronchoscopy and explored various in silico approaches to dealing with the contamination post-sequencing. Our analyses included quantitative PCR and targeted amplicon sequencing of the bacterial 16S rRNA gene. Results The mean bacterial load varied by sample type for the 23 study subjects (oral wash>1st fraction of protected bronchoalveolar lavage>protected specimen brush>2nd fraction of protected bronchoalveolar lavage; p < 0.001). By comparison to a dilution series of know bacterial composition and load, an estimated 10–50% of the bacterial community profiles for lower airway samples could be traced back to contaminating bacterial DNA introduced from the laboratory. We determined the main source of laboratory contaminants to be the DNA extraction kit (FastDNA Spin Kit). The removal of contaminants identified using tools within the Decontam R package appeared to provide a balance between keeping and removing taxa found in both negative controls and study samples. Conclusions The influence of laboratory contamination will vary across airway microbiome studies. By reporting estimates of contaminant levels and taking use of contaminant identification tools (e.g. the Decontam R package) based on statistical models that limit the subjectivity of the researcher, the accuracy of inter-study comparisons can be improved

    Laboratory contamination in airway microbiome studies

    Get PDF
    Background The low bacterial load in samples acquired from the lungs, have made studies on the airway microbiome vulnerable to contamination from bacterial DNA introduced during sampling and laboratory processing. We have examined the impact of laboratory contamination on samples collected from the lower airways by protected (through a sterile catheter) bronchoscopy and explored various in silico approaches to dealing with the contamination post-sequencing. Our analyses included quantitative PCR and targeted amplicon sequencing of the bacterial 16S rRNA gene. Results The mean bacterial load varied by sample type for the 23 study subjects (oral wash>1st fraction of protected bronchoalveolar lavage>protected specimen brush>2nd fraction of protected bronchoalveolar lavage; p < 0.001). By comparison to a dilution series of know bacterial composition and load, an estimated 10–50% of the bacterial community profiles for lower airway samples could be traced back to contaminating bacterial DNA introduced from the laboratory. We determined the main source of laboratory contaminants to be the DNA extraction kit (FastDNA Spin Kit). The removal of contaminants identified using tools within the Decontam R package appeared to provide a balance between keeping and removing taxa found in both negative controls and study samples. Conclusions The influence of laboratory contamination will vary across airway microbiome studies. By reporting estimates of contaminant levels and taking use of contaminant identification tools (e.g. the Decontam R package) based on statistical models that limit the subjectivity of the researcher, the accuracy of inter-study comparisons can be improved

    Drengenes_LaboratoryContamination_DRYAD_fastq

    No full text
    Fastq files generated by Illumina MiSeq sequencing of the bacterial 16S rRNA gene region V3V4 (164 samples, paired-end reads)

    Data from: Laboratory contamination in airway microbiome studies

    Get PDF
    Background: The low bacterial load in samples acquired from the lungs, have made studies on the airway microbiome vulnerable to contamination from bacterial DNA introduced during sampling and laboratory processing. We have examined the impact of laboratory contamination on samples collected from the lower airways by protected (through a sterile catheter) bronchoscopy and explored various in silico approaches to dealing with the contamination post-sequencing. Our analyses included quantitative PCR and targeted amplicon sequencing of the bacterial 16S rRNA gene. Results: The mean bacterial load varied by sample type for the 23 study subjects (oral wash>1st fraction of protected bronchoalveolar lavage>protected specimen brush>2nd fraction of protected bronchoalveolar lavage; p < 0.001). By comparison to a dilution series of know bacterial composition and load, an estimated 10-50% of the bacterial community profiles for lower airway samples could be traced back to contaminating bacterial DNA introduced from the laboratory. We determined the main source of laboratory contaminants to be the DNA extraction kit (FastDNA Spin Kit). The removal of contaminants identified using tools within the Decontam R package appeared to provide a balance between keeping and removing taxa found in both negative controls and study samples. Conclusions: The influence of laboratory contamination will vary across airway microbiome studies. By reporting estimates of contaminant levels and taking use of contaminant identification tools (e.g. the Decontam R package) based on statistical models that limit the subjectivity of the researcher, the accuracy of inter-study comparisons can be improved

    Motivation and response rates in bronchoscopy studies

    Get PDF
    Background Bronchoscopy is frequently used to sample the lower airways in lung microbiome studies. Despite being a safe procedure, it is associated with discomfort that may result in reservations regarding participation in research bronchoscopy studies. Information on participation in research bronchoscopy studies is limited. We report response rates, reasons for non-response, motivation for participation, and predictors of participation in a large-scale single-centre bronchoscopy study (“MicroCOPD”). Methods Two hundred forty-nine participants underwent at least one bronchoscopy in addition to being examined by a physician, having lung function tested, and being offered a CT scan of the heart and lungs (subjects > 40 years). Each participant was asked an open question regarding motivation. Non-response reasons were gathered, and response rates were calculated. Results The study had a response rate just above 50%, and men had a significantly higher response rate than women (56.5% vs. 44.8%, p = 0.01). Procedural fear was the most common non-response reason. Most participants participated due to perceived personal benefit, but a large proportion did also participate to help others and contribute to science. Men were less likely to give exclusive altruistic motives, whereas subjects with asthma were more likely to report exclusive personal benefit as main motive. Conclusion Response rates of about 50% in bronchoscopy studies make large bronchoscopy studies feasible, but the fact that participants are motivated by their own health status places a large responsibility on the investigators regarding the accuracy of the provided study information
    corecore