4 research outputs found

    International nosocomial infection control consortium (INICC) report, data summary of 36 countries, for 2004-2009

    Get PDF
    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright © 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved

    Device-associated infection rates in adult and pediatric intensive care units of hospitals in Egypt. International Nosocomial Infection Control Consortium (INICC) findings

    Get PDF
    ► Surveillance of device-associated infections in intensive care units in Egypt is proposed. ► Using INICC methods and CDC-NHSN definitions enabled us to obtain comparative data. ► Systematic surveillance enables benchmarking against other health care settings. ► Device-associated rates in our settings are higher than in developed countries. ► Infection control programs with surveillance must be prioritized in these settings. To determine the rate of device-associated healthcare-associated infections (DA-HAIs) at a respiratory intensive care unit (RICU) and in the pediatric intensive care units (PICUs) of member hospitals of the International Nosocomial Infection Control Consortium (INICC) in Egypt. A prospective cohort DA-HAI surveillance study was conducted from December 2008 to July 2010 by applying the methodology of the INICC and the definitions of the NHSN-CDC. In the RICU, 473 patients were hospitalized for 2930d and acquired 155 DA-HAIs, with an overall rate of 32.8%. There were 52.9 DA-HAIs per 1000 ICU-days. In the PICUs, 143 patients were hospitalized for 1535d and acquired 35 DA-HAIs, with an overall rate of 24.5%. There were 22.8 DA-HAIs per 1000 ICU-days. The central line-associated blood stream infection (CLABSI) rate was 22.5 per 1000 line-days in the RICU and 18.8 in the PICUs; the ventilator-associated pneumonia (VAP) rate was 73.4 per 1000 ventilator-days in the RICU and 31.8 in the PICUs; and the catheter-associated urinary tract infection (CAUTI) rate was 34.2 per 1000 catheter-days in the RICU. DA-HAIs in the ICUs in Egypt pose greater threats to patient safety than in industrialized countries, and infection control programs, including surveillance and guidelines, must become a priority

    Erratum: International Nosocomial Infection Control Consortium report, data summary of 43 countries for 2007-2012. Device-associated module (American Journal of Infection Control (2014) 42 (942-956))

    No full text
    corecore