12 research outputs found

    Minimally Invasive Versus Open Liver Resections for Hepatocellular Carcinoma in Patients With Metabolic Syndrome

    Get PDF
    Objective: To compare minimally invasive (MILR) and open liver resections (OLRs) for hepatocellular carcinoma (HCC) in patients with metabolic syndrome (MS).Background: Liver resections for HCC on MS are associated with high perioperative morbidity and mortality. No data on the minimally invasive approach in this setting exist.Material and Methods: A multicenter study involving 24 institutions was conducted. Propensity scores were calculated, and inverse probability weighting was used to weight comparisons. Short-term and long-term outcomes were investigated.Results: A total of 996 patients were included: 580 in OLR and 416 in MILR. After weighing, groups were well matched. Blood loss was similar between groups (OLR 275.9 +/- 3.1 vs MILR 226 +/- 4.0, P=0.146). There were no significant differences in 90-day morbidity (38.9% vs 31.9% OLRs and MILRs, P=0.08) and mortality (2.4% vs 2.2% OLRs and MILRs, P=0.84). MILRs were associated with lower rates of major complications (9.3% vs 15.3%, P=0.015), posthepatectomy liver failure (0.6% vs 4.3%, P=0.008), and bile leaks (2.2% vs 6.4%, P=0.003); ascites was significantly lower at postoperative day 1 (2.7% vs 8.1%, P=0.002) and day 3 (3.1% vs 11.4%, P<0.001); hospital stay was significantly shorter (5.8 +/- 1.9 vs 7.5 +/- 1.7, P<0.001). There was no significant difference in overall survival and disease-free survival.Conclusions: MILR for HCC on MS is associated with equivalent perioperative and oncological outcomes to OLRs. Fewer major complications, posthepatectomy liver failures, ascites, and bile leaks can be obtained, with a shorter hospital stay. The combination of lower short-term severe morbidity and equivalent oncologic outcomes favor MILR for MS when feasible

    Surgical approach to microwave and radiofrequency liver ablation for hepatocellular carcinoma and colorectal liver metastases less than 5 cm: A systematic review and meta-analysis

    No full text
    Background:Primary hepatocellular carcinoma (HCC) and colorectal liver metastases (CRLM) represent the two most common malignant neoplasms of the liver. The objective of this study was to assess outcomes of surgical approaches to liver ablation comparing laparoscopic versus percutaneous microwave ablation (MWA), and MWA versus radiofrequency ablation (RFA) in patients with HCC or CRLM lesions smaller than 5 cm. Methods:A systematic review was conducted across seven databases, including PubMed, Embase, and Cochrane, to identify all comparative studies between 1937 and 2021. Two independent reviewers screened for eligibility, extracted data for selected studies, and assessed study bias using the modified Newcastle Ottawa Scale. Random effects meta-analyses were subsequently performed on all available comparative data. Results:From 1066 records screened, 11 studies were deemed relevant to the study and warranted inclusion. Eight of the 11 studies were at high or uncertain risk for bias. Our meta-analyses of two studies revealed that laparoscopic MW ablation had significantly higher complication rates compared to a percutaneous approach (risk ratio = 4.66; 95% confidence interval = [1.23, 17.22]), but otherwise similar incomplete ablation rates, local recurrence, and oncologic outcomes. The remaining nine studies demonstrated similar efficacy of MWA and RFA, as measured by incomplete ablation, complication rates, local/regional recurrence, and oncologic outcomes, for both HCC and CRLM lesions less than 5 cm (p \u3e 0.05 for all outcomes). There was no statistical subgroup interaction in the analysis of tumors \u3c 3 cm. Conclusion:The available comparative evidence regarding both laparoscopic versus percutaneous MWA and MWA versus RFA is limited, evident by the few studies that suffer from high/uncertain risk of bias. Additional high-quality randomized trials or statistically matched cohort studies with sufficient granularity of patient variables, institutional experience, and physician specialty/training will be useful in informing clinical decision making for the ablative treatment of HCC or CRLM

    SAGES/AHPBA guidelines for the use of microwave and radiofrequency liver ablation for the surgical treatment of hepatocellular carcinoma or colorectal liver metastases less than 5 cm

    No full text
    This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature's AM terms of use, but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: http://dx.doi.org/10.1007/s00464-023-10468-1. <br><br>Deposited by shareyourpaper.org and openaccessbutton.org. We've taken reasonable steps to ensure this content doesn't violate copyright. However, if you think it does you can request a takedown by emailing [email protected]
    corecore