8 research outputs found

    EFEITO BIOLÓGICO DO SOM FRENTE AO DESENVOLVIMENTO LARVAL DE AEDES AEGYPTI

    Get PDF
    The perception or sensation of sound is generated from vibrations of air particles in the organ responsible for detecting these variations, the eardrum in the case of humans and the sensory organs in the case of insects. Much is said about means of vector controls, so chemicals, microorganisms and even sound waves are usually used as electronic repellents. In order to understand how the larval development of Aedes aegypti occurs, subjected to specific sound frequencies, experiments were carried out in triplicate with sound devices emitting waves at the frequencies of 14, 40 and 80 kHz. This experiment was divided into two moments, the first without intermittency and the second with a timer controlling the sound-emitting devices, applied to trays containing A. aegypti larvae that were hatched in the laboratory of the Serra Talhada Academic Unit. Through the experiment it was possible to perceive, using the R-studio program with the T-student test, that the results were not significant in relation to the development time, but it was possible to observe that there was an acceleration in the larval of those who had the timer controlling the periods of activation of the sound devices.La percepción o sensación del sonido se genera a partir de las vibraciones de las partículas de aire en el órgano encargado de detectar estas variaciones, el tímpano en el caso de los humanos y los órganos sensoriales en el caso de los insectos. Mucho se habla de los medios de control de vectores, por lo que se suelen utilizar productos químicos, microorganismos e incluso ondas sonoras como repelentes electrónicos. Con el fin de comprender cómo se produce el desarrollo larvario de Aedes aegypti, sometido a frecuencias sonoras específicas, se realizaron experimentos por triplicado con dispositivos sonoros que emiten ondas en las frecuencias de 14, 40 y 80 kHz. Este experimento se dividió en dos momentos, el primero sin intermitencia y el segundo con un temporizador que controlaba los dispositivos emisores de sonido, aplicados a bandejas que contenían larvas de A. aegypti que fueron incubadas en el laboratorio de la Unidad Académica Serra Talhada. A través del experimento se pudo percibir, utilizando el programa R-studio con la prueba T-student, que los resultados no fueron significativos en relación al tiempo de desarrollo, pero sí se pudo observar que hubo una aceleración en las larvas de aquellos que tenían el temporizador controlando los periodos de activación de los dispositivos sonoros.A percepção ou sensação de som é gerada a partir de vibrações das partículas do ar no órgão responsável por detectar essas variações, o tímpano no caso dos humanos e os órgãos sensoriais no caso dos insetos. Muito se fala em meios de controles vetoriais, para tanto, usualmente são utilizados produtos químicos, microrganismos e até ondas sonoras como repelentes eletrônicos. Com o intuito de compreender como se dá o desenvolvimento larval de Aedes aegypti, submetido a frequências sonoras especificas, foram realizados experimentos em triplicata com aparelhos sonoros emitindo ondas nas frequências de 14, 40 e 80 kHz. Esse experimento foi dividido em dois momentos, um primeiro sem intermitência e um segundo com um timer controlando os aparelhos emissores de som, aplicando-se em bandejas contendo larvas de A. aegypti que foram eclodidas no laboratório da Unidade Acadêmica de Serra Talhada. Através do experimento foi possível perceber, utilizando-se o programa R-studio com o teste T-student, que os resultados não foram significativos com relação ao tempo de desenvolvimento, mas foi possível observar que houve uma aceleração no larval das que estavam com o timer controlando os períodos de acionamento dos aparelhos sonoros.A percepção ou sensação de som é gerada a partir de vibrações das partículas do ar no órgão responsável por detectar essas variações, o tímpano no caso dos humanos e os órgãos sensoriais no caso dos insetos. Muito se fala em meios de controles vetoriais, para tanto, usualmente são utilizados produtos químicos, microrganismos e até ondas sonoras como repelentes eletrônicos. Com o intuito de compreender como se dá o desenvolvimento larval de Aedes aegypti, submetido a frequências sonoras especificas, foram realizados experimentos em triplicata com aparelhos sonoros emitindo ondas nas frequências de 14, 40 e 80 kHz. Esse experimento foi dividido em dois momentos, um primeiro sem intermitência e um segundo com um timer controlando os aparelhos emissores de som, aplicando-se em bandejas contendo larvas de A. aegypti que foram eclodidas no laboratório da Unidade Acadêmica de Serra Talhada. Através do experimento foi possível perceber, utilizando-se o programa R-studio com o teste T-student, que os resultados não foram significativos com relação ao tempo de desenvolvimento, mas foi possível observar que houve uma aceleração no larval das que estavam com o timer controlando os períodos de acionamento dos aparelhos sonoros

    Wavelet-Based determination of Cu and Pb in water samples using potentiometric stripping analysis with a Lab-Made potentiostat

    Full text link
    This paper demonstrates the possibility of simultaneously determining lead and copper in mineral, river and tap water by potentiometric stripping analysis using a low-cost lab-made potentiostat and a wavelet-based signal processing method. Pb(II) and Cu(II) concentrations were found to be in the range 3-7 µg L-1. Relative standard deviations were on average smaller than 3%, which is satisfactory in view of the trace concentration. For comparison, the determination was also carried out by using a high-end commercial equipment (μAutolab Type II, Eco Chemie). The average and standard deviation of the results were similar to those obtained with the lab-made potentiostat. No significant statistical difference was verified according to a paired t-test at a confidence level of 95%

    Um sistema microcontrolado para o monitoramento on-line, in situ e remoto de pH, condutividade e temperatura de águas

    Full text link
    A portable microcontrolled system is proposed to monitor conductivity, temperature and pH in on-line, in situ and remote way from a water reservoir faraway 200 m. The system comprises two modules: one for data reception (located in laboratory) and another for data acquisition/transmission (located near water reservoir). It uses a microcontroller and a transceiver to remote data transmission/reception by radio frequency. Variations of water parameters were simultaneously monitored without interruption during a period of ten hours with a relative error about 4.0 %. The developed system showed simple, stable, accurate, robust and low-cost to determine parameters of water in field

    Desenvolvimento de um espectrômetro de absorção atômica com atomização eletrotérmica empregando filamento de tungstênio e detecção com arranjo de fotodiodos

    No full text
    Nos últimos anos, a espectrometria de absorção atômica com atomização eletrotérmica tem evoluído bastante e hoje vêm sendo desenvolvidos equipamentos de menor custo que ocupam menor espaço físico, utilizando filamento de tungstênio como atomizador eletrotérmico. Porém, os equipamentos até então desenvolvidos apresentam certa complexidade quanto à sua instrumentação. Com o intuito de superar alguns inconvenientes destes equipamentos e contribuir para o avanço das pesquisas na área de instrumentação analítica, foi desenvolvido neste trabalho um instrumento simples empregando a atomização eletrotérmica com filamento de tungstênio e um detector de arranjo de fotodiodos, que permite a determinação simultânea de metais por absorção atômica em análise multicomponente. Além disso, procurando agilizar as etapas que antecedem as medidas analíticas, foi desenvolvido um sistema automático de preparação de soluções e/ ou misturas padrão de calibração. O controle de todo o instrumento bem como do sistema de preparação de soluções é feito por um microcomputador através de um software desenvolvido em linguagem gráfica Labview 5.1. Os resultados obtidos com o equipamento desenvolvido foram comparados com os obtidos por um espectrômetro comercial Perkin Elmer para determinação de Cu por espectrometria de absorção atômica com chama. As medidas foram feitas em triplicatas e o desvio padrão relativo foi em média igual a 1,7%. Os resultados obtidos com os dois equipamentos apresentaram boa concordância comprovando a potencialidade do instrumento desenvolvido. O módulo de preparação de misturas e/ ou soluções foi testado na preparação de misturas padrão de calibração contendo Fe, Mn, Cr, Ni e Mo. Ele foi acoplado a um ICP-OES e os resultados apresentaram pequenos desvios padrão com o máximo de 1,7% para o Fe. Os resultados obtidos com este trabalho mostraram que o instrumento proposto é viável e que pode ser utilizado na determinação de metais em diferentes tipos de amostra e que o módulo de preparação de misturas pode ser acoplado a qualquer instrumento analítico que necessite da preparação de soluções ou misturas de calibraçã

    Uma interface lab-made para aquisição de sinais analógicos instrumentais via porta paralela do microcomputador A lab-made interface for acquisition of instrumental analog signals at the parallel port of a microcomputer

    No full text
    <abstract language="eng">A lab-made interface for acquisition of instrumental analog signals between 0 and 5 V at a frequency up to 670 kHz at the parallel port of a microcomputer is described. Since it uses few and small components, it was built into the connector of a printer parallel cable. Its performance was evaluated by monitoring the signals of four different instruments and similar analytical curves were obtained with the interface and from readings from the instrument' displays. Because the components are cheap (~U$35,00) and easy to get, the proposed interface is a simple and economical alternative for data acquisition in small laboratories for routine work, research and teaching
    corecore