4 research outputs found

    EVALUATION OF RADIATION DOSE TO THE OPERATOR AND THE EFFECTIVENESS OF PROTECTIVE MEASURES IN EXAMINATIONS WITH PORTABLE RADIOGRAPHIC DEVICES: A SYSTEMATIC REVIEW

    No full text
    With the advance in the commercialization and use of the portable radiographic device in private and university clinics, it is extremely important to know the safety of this equipment for routine clinical use in these environments. Therefore, as to date (09/20/2021), no systematic review on this topic have been found in the different databases, and as this type of investigation is extremely important, the aim of the present study will be to carry out a systematic review with laboratory studies to assess the radiation dose to the operator and the effectiveness of protective measures in examinations with portable radiographic devices

    Avaliação dos níveis de pressão sonora emitidos pelo aparelho de ressonância magnética

    No full text
    RESUMO Objetivo: mensurar o nível de pressão sonora emitido pelo aparelho de ressonância magnética em funcionamento e verificar as sensações auditivas descritas pelos indivíduos submetidos a este exame após a realização do mesmo. Métodos: foi realizada a mensuração do ruído produzido, durante a aquisição das imagens, por meio de um medidor de nível de pressão sonora (decibelímetro) e a aplicação de um questionário com a finalidade de verificar as sensações auditivas apresentadas por estes indivíduos após a realização do exame. Tal procedimento foi aplicado a 60 indivíduos submetidos ao exame de ressonância magnética do crânio. Resultados: o nível de pressão sonora média apresentada durante a realização do exame foi inferior ao nível de intensidade considerado como risco para lesões auditivas. No entanto, sensações como zumbido, ansiedade, plenitude auricular e alívio após o término do exame foram citados pelos indivíduos após a execução do mesmo. Conclusão: é pertinente o uso de protetores auriculares como medida preventiva para o controle do nível de ruído que atinge a cóclea do indivíduo, minimizando desta forma os efeitos físicos e psicossociais decorrentes da exposição ao ruído

    Diagnóstico do defeito ósseo de Stafne por meio de tomografia computadorizada de feixe cônico: relato de caso

    No full text
    O defeito ósseo de Stafne possui o diagnóstico controverso por apresentar imagem semelhante às lesões benignas e malignas dos maxilares, principalmente quando é visualizado em radiografias convencionais, o que pode proporcionar intervenções cirúrgicas desnecessárias. O presente trabalho tem como objetivo descrever um relato de caso clínico de defeito ósseo de Stafne diagnosticado por meio de tomografia computadorizada de feixe cônico (TCFC), demonstrando as características imaginológicas no exame tomográfico

    Two and Three-dimensional Parameters in Cone-beam Computed Tomography Monitoring of Apical Periodontitis in Traumatized Teeth: Case Report and Long-term Follow-up

    No full text
    Assessment of apical periodontitis (AP) is a challenging task. This case report highlights the CBCT diagnosis and monitoring of periapical radiolucency (PR) using ITK-SNAP software 3.8v in a complex clinical scenario of three traumatized anterior teeth. An 11-year-old male patient complained of recurrent swelling and pain in the maxillary incisor region (teeth #11 and #21).  His parents reported a history of traumatic injury affecting these teeth two years back. Digital periapical radiographic (DPR) and cone-beam computed tomography (CBCT) were requested. PR was identified on teeth #11, #21, and # 22. In tooth #22, besides a PR, an area suggesting internal root resorption or oblique root fracture was observed. The teeth were shaped and dressing with calcium hydroxide Ca(OH)2. MTA repair was delivered to the apical portion of the canals (approximately 3 mm). The remainder of the canal was filled with thermoplastic gutta-percha and Endosequence sealer. After one year, the patient returned complaining of pain in tooth #11. Radiographically, the PR of tooth #11 did not reduce. A CBCT was taken, showing a reduction of radiolucency. The patient was clinical and radiographically re-evaluated for 6 months, and he remained asymptomatic. After three years of follow-up, the patient suffered a new trauma on teeth #11 and #21. As tooth #11 presents mobility and biting pain, a new CBCT was requested due to the risk of a possible root fracture. So, the PR was synchronously monitored with linear measurements and volumetric analysis using ITK-SNAP software 3.8v. In this case, the volumetric evaluation was essential to identify the PR's correct dimensions, reducing image interpretation's subjectivity. At 48-month follow-up, the patient was symptoms free and radiographically showed a reduction in the PR's size, compatible with osseous healing
    corecore