16 research outputs found

    Comparative study of carbon quantification methods in soil with high Fe contents (Oxisols)

    Get PDF
    Soil organic matter (SOM) plays an important role in physical, chemical and biological properties of soil. Therefore, the amount of SOM is important for soil management for sustainable agriculture. The objective of this work was to evaluate the amount of SOM in oxisols by different methods and compare them, using principal component analysis, regarding their limitations. The methods used in this work were Walkley-Black, elemental analysis, total organic carbon (TOC) and thermogravimetry. According to our results, TOC and elemental analysis were the most satisfactory methods for carbon quantification, due to their better accuracy and reproducibility.FAPESPCNP

    Chromobacterium Violaceum Sepsis in Minas Gerais

    Get PDF
    Infection by Chromobacterium violaceum, known as chromobacteriosis, is a rare cause of severe sepsis with rapid spread and high mortality. In February 2009, a 14-year-old male patient was admitted to Santa Casa of Misericórdia of Juiz de Fora Hospital, and he deteriorated rapidly with severe sepsis and death by chromobacteriosis. In this article we discuss the main clinical fidings, sensitivity profie, and antimicrobial therapy of this case

    Not available

    No full text
    Filmes ultrafinos de polímeros condutores, polímeros naturais e lipídios foram depositados sobre microeletrodos interdigitados a fim de se desenvolver sensores capazes de detectar gases liberados durante o processo de amadurecimento de frutas e avaliar a qualidade de bebidas. Foi investigado o efeito do ácido dopante em um filme self-assembly de poli(o-etoxianilina) (POEA) na detecção do gás etileno utilizando-se medidas elétricas em corrente contínua (DC). Observou-se um aumento na sensibilidade do dispositivo aos gases quando o polímero é dopado com o ácido p-toluenosulfônico, acompanhado de um comportamento não ôhmico na resposta elétrica do sensor. Em contraste, a dopagem da POEA em ácido clorídrico indica um comportamento ôhmico, sem melhorar a sensibilidade do sensor polimérico ao gás. O sensoriamento dos gases etileno e CO2 também foi realizado por meio das medidas elétricas em corrente alternada (AC), que se mostrou mais eficiente tanto na aquisição dos dados quanto na sensibilidade do sensor aos gases de interesse. A variação de umidade foi observada de forma bastante pronunciada pelo sensor polimérico, que demonstrou menores valores de resistência elétrica para maiores valores de umidade relativa. A combinação das diferentes técnicas de deposição de filmes ultrafinos, automontagem (SA) e Langmuir - Blodgett (LB), e a escolha adequada de diversos materiais (polímeros condutores, lignina e lipídio) para a fabricação das unidades sensoriais de uma \"língua eletrônica\" permitiu o reconhecimento de soluções padrões de paladares distintos e a análise da qualidade de vinhos. A sensibilidade da língua eletrônica mostrou-se acima da sensibilidade humana, sendo muito eficiente tanto na diferenciação de vinhos com características semelhantes de paladar, como por exemplo, distinguir Cabernet Sauvignon de Cabemet Franc, como entre vinhos rosados, brancos e tintos de diferentes tipos e produtores. O modelo teórico que combina capacitores e resistores em um circuito equivalente descreveu com muito boa aproximação o comportamento do sistema em estudo, o que foi evidenciado pela boa concordância entre os valores calculados e aqueles encontrados na literatura para as constantes dielétricas do 16-mero e ácido esteárico.Ultra-thin films of conducting polymers, a natural polymer and a lipid-like material were deposited onto gold interdigitated rnicroelectrodes envisaging the development of sensors able to detect gases released in the fruit ripening process and also to evaluate the quality of some beverages. It was checked the doping effect over a self assembled film of poly(o-ethoxyalinine) (POEA) regarding to the detection of ethylene through DC measurements. The POEA doping with p-toluenesulphonic acid (TSA) leads to a non-ohmic behavior and to an increase in the sensitivity of the device. On the other band, HCI doping points to an ohmic behavior regardless to the gas with no improvement in the sensor sensitivity. AC measurements were also acquired in the assessment of the sensor, displaying a better data acquisition and a higher sensibility of the polymeric film to the gaseous species ana1ysed. The humidity effect was quite strong in the sensor response, as the polymeric film became more conducting at high humidity environments. The combination of the self-assembly and Langmuir-Blodgett techniques together with the right choice of the materials (conducting polymers, a natural polymer and stearic acid) to make the sensing units of an electronic tongue allowed the distinction of tastants and the appraisal of wine quality in a simple and cheaper way than the conventional techniques normally employed in the analysis of complex liquid system threshold of the device was quite below of that observed in humans, and a very good efficiency was observed in the distinction of similar wines, e.g., Cabernet Sauvignon and Cabernet Franc as well as between white, rose and red wines from different brands and producers. A theoretical model using an equivalent circuit described well the system investigated providing a very good agreement between the relative permittivity values found in the literature and those from the curve fitting for 16-mer polyaniline and stearic aci

    Sensors made with polymers for detecting heavy metals and assessing water quality

    No full text
    Línguas eletrônicas constituídas de filmes nanoestruturados depositados sobre eletrodos metálicos, e empregando a técnica de espectroscopia de impedância como princípio de detecção, vêm apresentando excelentes resultados para a diferenciação de substâncias que constituem os paladares básicos e na detecção de impurezas em amostras líquidas. A principal limitação para o uso comercial é a necessidade da substituição das unidades sensoriais do arranjo, que necessita de recalibração. Nesta tese introduzimos um novo arranjo de unidades sensoriais, constituídos de eletrodos de cromo eletrodepositados, que não necessitam de filmes finos. Usando arranjos de cinco ou dez unidades sensoriais nominalmente idênticas, obtivemos uma língua eletrônica capaz de detectar paladares básicos e íons de cobre em água em concentrações abaixo de 1μM. As diferenças nas respostas elétricas dos eletrodos são oriundas das diferenças na sua morfologia. A alta sensibilidade apresentada foi explorada na análise de vinhos e amostras de águas coletadas de vários rios e lagos. Similarmente às línguas eletrônicas com filmes nanoestruturados, o arranjo sensorial de eletrodos de cromo foi capaz de distinguir vinhos de uma mesma varietal e produtor, mas de diferentes safras, e de um mesmo produtor e safra, mas de diferentes varietais. Tentamos também melhorar o desempenho das línguas eletrônicas combinando unidades constituídas de filmes finos de quitosana e poli(o-etoxianilina). Apesar do interesse nas propriedades advindas da interação entre esses materiais, especialmente quando a quitosana foi utilizada na forma de nanopartículas, o desempenho foi similar ao da língua eletrônica contendo eletrodos de cromo sem filmes.Electronic tongues based on nanostructured films and employing impedance spectroscopy as the principle of detection have proven excellent to distinguish between basic tastes and detect trace amounts of impurities in liquid samples. The main limitation for a commercial use, though, is the need to replace the sensing units of the sensor array, which requires recalibration, owing to the relatively poor stability of the nanostructured films. In this thesis we introduce a new arrangement for the sensing units, which are produced from electrodeposited chrome electrodes, with no need to adsorb an organic film. Using an array with 5 or 10 nominally identical chrome electrodes, we obtained an electronic tongue capable of detecting basic tastes and copper ions in water down to the 1μM level. The differences in electrical properties for the electrodes arose from differences in morphology. Furthermore, this high sensitivity could be exploited in the analysis of wines, and water samples collected from various rivers and lakes. Similarly to electronic tongues made with nanostructured films, the sensor array with electrodeposited chrome electrodes was capable of distinguishing wines from the same grape and producer, but different vintages, or from the same producer and vintage but different grapes. We also attempted to optimize the performance of electronic tongues by combining sensing units made of chitosan and poly(o-ethoxyaniline). In spite of the interesting properties deriving from the interaction between these components, especially when chitosan nanoparticles were used, the performance of the sensor array was similar to that of the electronic tongue obtained with bare chrome electrodes

    Not available

    No full text
    Filmes ultrafinos de polímeros condutores, polímeros naturais e lipídios foram depositados sobre microeletrodos interdigitados a fim de se desenvolver sensores capazes de detectar gases liberados durante o processo de amadurecimento de frutas e avaliar a qualidade de bebidas. Foi investigado o efeito do ácido dopante em um filme self-assembly de poli(o-etoxianilina) (POEA) na detecção do gás etileno utilizando-se medidas elétricas em corrente contínua (DC). Observou-se um aumento na sensibilidade do dispositivo aos gases quando o polímero é dopado com o ácido p-toluenosulfônico, acompanhado de um comportamento não ôhmico na resposta elétrica do sensor. Em contraste, a dopagem da POEA em ácido clorídrico indica um comportamento ôhmico, sem melhorar a sensibilidade do sensor polimérico ao gás. O sensoriamento dos gases etileno e CO2 também foi realizado por meio das medidas elétricas em corrente alternada (AC), que se mostrou mais eficiente tanto na aquisição dos dados quanto na sensibilidade do sensor aos gases de interesse. A variação de umidade foi observada de forma bastante pronunciada pelo sensor polimérico, que demonstrou menores valores de resistência elétrica para maiores valores de umidade relativa. A combinação das diferentes técnicas de deposição de filmes ultrafinos, automontagem (SA) e Langmuir - Blodgett (LB), e a escolha adequada de diversos materiais (polímeros condutores, lignina e lipídio) para a fabricação das unidades sensoriais de uma \"língua eletrônica\" permitiu o reconhecimento de soluções padrões de paladares distintos e a análise da qualidade de vinhos. A sensibilidade da língua eletrônica mostrou-se acima da sensibilidade humana, sendo muito eficiente tanto na diferenciação de vinhos com características semelhantes de paladar, como por exemplo, distinguir Cabernet Sauvignon de Cabemet Franc, como entre vinhos rosados, brancos e tintos de diferentes tipos e produtores. O modelo teórico que combina capacitores e resistores em um circuito equivalente descreveu com muito boa aproximação o comportamento do sistema em estudo, o que foi evidenciado pela boa concordância entre os valores calculados e aqueles encontrados na literatura para as constantes dielétricas do 16-mero e ácido esteárico.Ultra-thin films of conducting polymers, a natural polymer and a lipid-like material were deposited onto gold interdigitated rnicroelectrodes envisaging the development of sensors able to detect gases released in the fruit ripening process and also to evaluate the quality of some beverages. It was checked the doping effect over a self assembled film of poly(o-ethoxyalinine) (POEA) regarding to the detection of ethylene through DC measurements. The POEA doping with p-toluenesulphonic acid (TSA) leads to a non-ohmic behavior and to an increase in the sensitivity of the device. On the other band, HCI doping points to an ohmic behavior regardless to the gas with no improvement in the sensor sensitivity. AC measurements were also acquired in the assessment of the sensor, displaying a better data acquisition and a higher sensibility of the polymeric film to the gaseous species ana1ysed. The humidity effect was quite strong in the sensor response, as the polymeric film became more conducting at high humidity environments. The combination of the self-assembly and Langmuir-Blodgett techniques together with the right choice of the materials (conducting polymers, a natural polymer and stearic acid) to make the sensing units of an electronic tongue allowed the distinction of tastants and the appraisal of wine quality in a simple and cheaper way than the conventional techniques normally employed in the analysis of complex liquid system threshold of the device was quite below of that observed in humans, and a very good efficiency was observed in the distinction of similar wines, e.g., Cabernet Sauvignon and Cabernet Franc as well as between white, rose and red wines from different brands and producers. A theoretical model using an equivalent circuit described well the system investigated providing a very good agreement between the relative permittivity values found in the literature and those from the curve fitting for 16-mer polyaniline and stearic aci

    Sensors made with polymers for detecting heavy metals and assessing water quality

    No full text
    Línguas eletrônicas constituídas de filmes nanoestruturados depositados sobre eletrodos metálicos, e empregando a técnica de espectroscopia de impedância como princípio de detecção, vêm apresentando excelentes resultados para a diferenciação de substâncias que constituem os paladares básicos e na detecção de impurezas em amostras líquidas. A principal limitação para o uso comercial é a necessidade da substituição das unidades sensoriais do arranjo, que necessita de recalibração. Nesta tese introduzimos um novo arranjo de unidades sensoriais, constituídos de eletrodos de cromo eletrodepositados, que não necessitam de filmes finos. Usando arranjos de cinco ou dez unidades sensoriais nominalmente idênticas, obtivemos uma língua eletrônica capaz de detectar paladares básicos e íons de cobre em água em concentrações abaixo de 1μM. As diferenças nas respostas elétricas dos eletrodos são oriundas das diferenças na sua morfologia. A alta sensibilidade apresentada foi explorada na análise de vinhos e amostras de águas coletadas de vários rios e lagos. Similarmente às línguas eletrônicas com filmes nanoestruturados, o arranjo sensorial de eletrodos de cromo foi capaz de distinguir vinhos de uma mesma varietal e produtor, mas de diferentes safras, e de um mesmo produtor e safra, mas de diferentes varietais. Tentamos também melhorar o desempenho das línguas eletrônicas combinando unidades constituídas de filmes finos de quitosana e poli(o-etoxianilina). Apesar do interesse nas propriedades advindas da interação entre esses materiais, especialmente quando a quitosana foi utilizada na forma de nanopartículas, o desempenho foi similar ao da língua eletrônica contendo eletrodos de cromo sem filmes.Electronic tongues based on nanostructured films and employing impedance spectroscopy as the principle of detection have proven excellent to distinguish between basic tastes and detect trace amounts of impurities in liquid samples. The main limitation for a commercial use, though, is the need to replace the sensing units of the sensor array, which requires recalibration, owing to the relatively poor stability of the nanostructured films. In this thesis we introduce a new arrangement for the sensing units, which are produced from electrodeposited chrome electrodes, with no need to adsorb an organic film. Using an array with 5 or 10 nominally identical chrome electrodes, we obtained an electronic tongue capable of detecting basic tastes and copper ions in water down to the 1μM level. The differences in electrical properties for the electrodes arose from differences in morphology. Furthermore, this high sensitivity could be exploited in the analysis of wines, and water samples collected from various rivers and lakes. Similarly to electronic tongues made with nanostructured films, the sensor array with electrodeposited chrome electrodes was capable of distinguishing wines from the same grape and producer, but different vintages, or from the same producer and vintage but different grapes. We also attempted to optimize the performance of electronic tongues by combining sensing units made of chitosan and poly(o-ethoxyaniline). In spite of the interesting properties deriving from the interaction between these components, especially when chitosan nanoparticles were used, the performance of the sensor array was similar to that of the electronic tongue obtained with bare chrome electrodes

    Perfil e evolução clínica de pacientes com urticária crônica

    No full text
    In spite of therapeutic breakthroughs, chronic urticaria is one of the most frequent skin conditions. Objective: assess patient profile and clinical outcome of a population with chronic urticaria seen in a specialist facility. Sample and methods: Cross-sectional, observational study of patients seen in a specialist outpatient facility during the period 1993-2005. Patients with acute urticaria and dermatographism were excluded. Age, sex, etiology, clinical outcome, and treatment were the variables analyzed. Results: Mean age was 36.8 years (standard deviation 18.4 years), with 207 (83.1%) patients over 18 years old. 186 (74.7%) patients were female and 63 (25.3%) males. 167 patients (67.1%) were followed up, with a median of two subsequent consultations. Of these, 84 (50.3%) improved clinically, 79 (47.3%) stopped treatment and reported partial improvement, and 4 (2.4%) stopped treatment without any clinical improvement. In 170 (68.3%) no specific etiology was found. Of the 79 patients (31.7%) with a specific etiology for their chronic urticaria, 32 (40.5%) had an abnormality in the laboratory investigation of the thyroid function. Conclusion: The epidemiologic profile of our patients is in accordance with literature data, with a predominance of adult females and a high proportion of treatment interruption or interruption with partial improvement.Apesar dos avanços terapêuticos, a urticária constitui uma das dermatoses mais freqüentes. Objetivo: avaliar o perfil e a evolução clínica dos pacientes com urticária crônica (UC) atendidos em consultório de especialidade. Casuística e Métodos: Estudo observacional, seccional, dos pacientes atendidos em ambulatório de especialidade, no período de 1993 a 2005. Pacientes com quadro de urticária aguda e física foram excluídos. As variáveis analisadas foram idade, sexo, etiologia, bem como evolução clínica e tratamento. Resultados. A média da idade foi 36,8 anos, com desvio-padrão de 18,4 anos, com 207 (83,1%) pacientes tendo mais de 18 anos. 186 (74,7%) pacientes são do sexo feminino e 63 (25,3%), do sexo masculino. Na evolução clínica, verificou-se que 67,1% (167) dos pacientes continuaram o acompanhamento, com uma mediana de duas consultas subseqüentes. Nestes, a melhora clínica completa foi observada em 84 (50,3%) pacientes; a interrupção do tratamento com referência de melhora parcial, em 79 (47,3%) e a interrupção do tratamento com referência de nenhuma melhora clínica, em quatro (2,4%). Quanto à etiologia, em 170 (68,3%) pacientes não se conseguiu estabelecer uma causa específica. Entre os 79 (31,7%) pacientes que apresentaram uma causa para a UC, 32 (40,5%) tinham alguma alteração laboratorial ligada à tireóide. Conclusão: Observamos que o perfil epidemiológico dos pacientes segue o demonstrado na literatura, com predomínio em adultos e no sexo feminino, sendo elevado o número de pacientes que não dão continuidade ao acompanhamento ou com interrupção com melhora parcial

    Impacto do ecocardiograma transesofágico intraoperatório na mortalidade em cirurgia de revascularização do miocárdio com circulação extracorpórea

    Get PDF
    OBJETIVO: avaliar as taxas de mortalidade e morbidade de doentes submetidos à revascularização do miocárdio (RVM) com circulação extracorpórea (CEC) que utilizaram rotineiramente o ecocardiograma transesofágico intraoperatório (ETEio). MÉTODOS: estudo retrospectivo, observacional com avaliação de prontuários de 360 doentes no período entre abril de 2010 a abril de 2012. Foram analisados: idade, peso, altura sexo, EUROscore, diabete melito, fração de ejeção e artérias acometidas. Os desfechos foram compilados no intra e no pós-operatório (infarto do miocárdio, acidente vascular cerebral, disfunção renal, hemodiálise, fibrilação atrial, tempo de internação no centro de tratamento intensivo). RESULTADOS: foram incluídos 53 doentes, com 27 recebendo a monitoração. Foram excluídos 307 porque não foram operados pela mesma equipe cirúrgica. Os dois grupos foram homogêneos quanto a idade, peso e sexo, porém, a fração ejeção foi menor no grupo que recebeu o ecotransesofágico (G ETEio: 56,3%; G Não ETEio: 65,9% ± 11; p=0,01). Nos doentes em que não foi utilizado o ETEio, a mortalidade foi maior (G ETEio: 0% e G Não ETEio: 7,6%; p=0,01). Não houve diferença significativa entre os grupos quanto à incidência de acidente vascular encefálico, infarto agudo do miocárdio, fibrilação atrial aguda e lesão renal. CONCLUSÃO: a utilização do ecocardiograma transesofágico intraoperatório em pacientes submetidos à revascularização do miocárdio, com circulação extracorpórea, diminuiu a mortalidade perioperatória; orientou quanto a utilização dos fármacos inotrópicos e vasodilatadores e contribuiu para uma melhor evolução dos doentes
    corecore