88 research outputs found

    Does genetic anticipation occur in familial Alexander disease?

    Get PDF
    Alexander Disease (AxD) is a rare leukodystrophy caused by missense mutations of glial fibrillary acidic protein (GFAP). Primarily seen in infants and juveniles, it can present in adulthood. We report a family with inherited AxD in which the mother presented with symptoms many years after her daughter. We reviewed the age of onset in all published cases of familial AxD and found that 32 of 34 instances of parent–offspring pairs demonstrated an earlier age of onset in offspring compared to the parent. We suggest that genetic anticipation occurs in familial AxD and speculate that genetic mosaicism could explain this phenomenon

    Inflammation and In-Stent Restenosis: The Role of Serum Markers and Stent Characteristics in Carotid Artery Stenting

    Get PDF
    BACKGROUND: Carotid angioplasty and stenting (CAS) may currently be recommended especially in younger patients with a high-grade carotid artery stenosis. However, evidence is accumulating that in-stent restenosis (ISR) could be an important factor endangering the long-term efficacy of CAS. The aim of this study was to investigate the influence of inflammatory serum markers and procedure-related factors on ISR as diagnosed with duplex sonography. METHODS: We analyzed 210 CAS procedures in 194 patients which were done at a single university hospital between May 2003 and June 2010. Periprocedural C-reactive protein (CRP) and leukocyte count as well as stent design and geometry, and other periprocedural factors were analyzed with respect to the occurrence of an ISR as diagnosed with serial carotid duplex ultrasound investigations during clinical long-term follow-up. RESULTS: Over a median of 33.4 months follow-up (IQR: 14.9-53.7) of 210 procedures (mean age of 67.9±9.7 years, 71.9% male, 71.0% symptomatic) an ISR of ≥70% was detected in 5.7% after a median of 8.6 months (IQR: 3.4-17.3). After multiple regression analysis, leukocyte count after CAS-intervention (odds ratio (OR): 1.31, 95% confidence interval (CI): 1.02-1.69; p = 0.036), as well as stent length and width were associated with the development of an ISR during follow-up (OR: 1.25, 95% CI: 1.05-1.65, p = 0.022 and OR: 0.28, 95% CI: 0.09-0.84, p = 0.010). CONCLUSIONS: The majority of ISR during long-term follow-up after CAS occur within the first year. ISR is associated with periinterventional inflammation markers and influenced by certain stent characteristics such as stent length and width. Our findings support the assumption that stent geometry leading to vessel injury as well as periprocedural inflammation during CAS plays a pivotal role in the development of carotid artery ISR

    Length of carotid stenosis predicts peri-procedural stroke or death and restenosis in patients randomized to endovascular treatment or endarterectomy.

    Get PDF
    BACKGROUND: The anatomy of carotid stenosis may influence the outcome of endovascular treatment or carotid endarterectomy. Whether anatomy favors one treatment over the other in terms of safety or efficacy has not been investigated in randomized trials. METHODS: In 414 patients with mostly symptomatic carotid stenosis randomized to endovascular treatment (angioplasty or stenting; n = 213) or carotid endarterectomy (n = 211) in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS), the degree and length of stenosis and plaque surface irregularity were assessed on baseline intraarterial angiography. Outcome measures were stroke or death occurring between randomization and 30 days after treatment, and ipsilateral stroke and restenosis ≥50% during follow-up. RESULTS: Carotid stenosis longer than 0.65 times the common carotid artery diameter was associated with increased risk of peri-procedural stroke or death after both endovascular treatment [odds ratio 2.79 (1.17-6.65), P = 0.02] and carotid endarterectomy [2.43 (1.03-5.73), P = 0.04], and with increased long-term risk of restenosis in endovascular treatment [hazard ratio 1.68 (1.12-2.53), P = 0.01]. The excess in restenosis after endovascular treatment compared with carotid endarterectomy was significantly greater in patients with long stenosis than with short stenosis at baseline (interaction P = 0.003). Results remained significant after multivariate adjustment. No associations were found for degree of stenosis and plaque surface. CONCLUSIONS: Increasing stenosis length is an independent risk factor for peri-procedural stroke or death in endovascular treatment and carotid endarterectomy, without favoring one treatment over the other. However, the excess restenosis rate after endovascular treatment compared with carotid endarterectomy increases with longer stenosis at baseline. Stenosis length merits further investigation in carotid revascularisation trials

    Testing devices for the prevention and treatment of stroke and its complications

    Get PDF
    We are entering a challenging but exciting period when many new interventions may appear for stroke based on the use of devices. Hopefully these will lead to improved outcomes at a cost that can be afforded in most parts of the world. Nevertheless, it is vital that lessons are learnt from failures in the development of pharmacological interventions (and from some early device studies), including inadequate preclinical testing, suboptimal trial design and analysis, and underpowered studies. The device industry is far more disparate than that seen for pharmaceuticals; companies are very variable in size and experience in stroke, and are developing interventions across a wide range of stroke treatment and prevention. It is vital that companies work together where sales and marketing are not involved, including in understanding basic stroke mechanisms, prospective systematic reviews, and education of physicians. Where possible, industry and academics should also work closely together to ensure trials are designed to be relevant to patient care and outcomes. Additionally, regulation of the device industry lags behind that for pharmaceuticals, and it is critical that new interventions are shown to be safe and effective rather than just feasible. Phase IV postmarketing surveillance studies will also be needed to ensure that devices are safe when used in the ‘real-world’ and to pick up uncommon adverse events

    Die spektralphotometrische Analyse des Liquor cerebrospinalis im UV-Licht

    No full text

    Zur Allergiefrage in der Neurologie und Psychiatrie

    No full text

    Daseinsanalyse und Psychose

    No full text

    Strategies for asymptomatic carotid artery stenosis

    No full text
    • …
    corecore