18 research outputs found

    HBV-RNA Co-amplification May Influence HBV DNA Viral Load Determination

    Get PDF
    Despite effective hepatitis B virus (HBV)-DNA suppression, HBV RNA can circulate in patients receiving nucleoside/nucleotide analogues (NAs). Current assays quantify HBV DNA by either real-time polymerase chain reaction (PCR), which uses DNA polymerase, or transcription-mediated amplification, which uses reverse-transcriptase (RT) and RNA polymerase. We assessed the effect of RT capability on HBV-DNA quantification in samples from three cohorts, including patients with quantified HBV RNA. We compared the HBV-DNA levels by real-time PCR (cobas HBV, Roche 6800/8800; Xpert HBV, Cepheid), transcription-mediated amplification (Aptima HBV, Hologic), and real-time PCR with added RT capability (cobas HBV+RT). In the first cohort (n = 45) followed over 192 weeks of NA therapy, on-treatment HBV-DNA levels were higher with cobas HBV+RT than cobas HBV (mean difference: 0.14 log10 IU/mL). In a second cohort (n = 50) followed over 96 weeks of NA therapy, HBV-DNA viral load was significantly higher with the cobas HBV+RT and Aptima HBV compared with the cobas HBV test at all time points after initiation of NA therapy (mean difference: 0.65-1.16 log10 IU/mL). A clinically significant difference was not detected between the assays at baseline. In a third cohort (n = 53), after a median of 2.2 years of NA therapy, we detected HBV RNA (median 5.6 log10 copies/mL) in 23 patients (43.4%). Median HBV-DNA levels by Aptima HBV were 2.4 versus less than 1 log10 IU/mL in samples with HBV RNA and without HBV RNA, respectively (P = 0.0006). In treated patients with HBV RNA, Aptima HBV measured higher HBV-DNA levels than Xpert HBV and cobas HBV. Conclusion: Tests including an RT step may overestimate HBV DNA, particularly in samples with low viral loads as a result of NA therapy. This overestimation is likely due to amplification of HBV RNA and may have an impact on clinical decisions

    Multicenter comparison study of both analytical and clinical performance across four roche hepatitis C virus RNA assays utilizing different platforms

    No full text
    The efficacy of antiviral treatment for chronic hepatitis C virus (HCV) infection is determined by measuring HCV RNA at specific time points throughout therapy using highly sensitive and accurate HCV RNA assays. This study compared the performances of two recently developed real-time PCR HCV RNA assays, cobas HCV for use on the cobas 6800/8800 systems (cobas 6800/8800 HCV) and cobas HCV for use on the cobas 4800 system (cobas 4800 HCV), with those of two established assays, the Cobas AmpliPrep/Cobas TaqMan HCV quantitative test, version 2 (CAP/CTM v2) and the Cobas TaqMan HCV test, version 2 for use with the High Pure system (HPS/CTM v2). The limits of detection (LODs) and linearity at lower concentrations (5 to 1000 IU/ml) were assessed for cobas 6800/8800 HCV and cobas 4800 HCV using WHO standard traceable panels representing HCV genotypes (GT) 1 to 4. Pairwise assay comparisons were also performed using 245 clinical samples representing HCV GT 1 to GT 4. Results from cobas 6800/8800 HCV and cobas 4800 HCV were linear at low HCV RNA concentrations (<0.3 log10 IU/ml difference between expected and observed results) with LODs of 8.2 IU/ml and 11.7 IU/ml, respectively, for GT 1. The new assays showed excellent agreement with results from CAP/CTM v2 and HPS/CTM v2 in samples with quantifiable viral loads. The concordances using the 6 million IU/ml cutoff were high among all four assays (90 to 94%). In conclusion, the cobas 6800/8800 HCV and cobas 4800 HCV tests are sensitive and linear and correlate well with the established Roche assays used in clinical practice

    First identification of a recombinant form of hepatitis C virus in Austrian patients by full-genome next generation sequencing.

    No full text
    Hepatitis C virus (HCV) intergenotypic recombinant forms have been reported for various HCV genotypes/subtypes in several countries worldwide. In a recent study, four patients living in Austria had been identified to be possibly infected with a recombinant HCV strain. To clarify results and determine the point of recombination, full-genome next-generation sequencing using the Illumina MiSeq v2 300 cycle kit (Illumina, San Diego, CA, USA) was performed in the present study. Samples of all of the patients contained the recombinant HCV strain 2k/1b. The point of recombination was found to be within the HCV NS2 gene between nucleotide positions 3189-3200 based on H77 numbering. While three of four patients were male and had migration background from Chechnya (n = 2) and Azerbaijan (n = 1), the forth patient was a female born in Austria. Three of the four patients including the female had intravenous drug abuse as a risk factor for HCV transmission. While sequencing techniques are limited to a few specialized laboratories, a genotyping assay that uses both ends of the HCV genome should be employed to identify patients infected with a recombinant HCV strain. The correct identification of recombinant strains also has an impact considering the tailored choice of anti-HCV treatment

    Utility of the new cobas HCV test for viral load monitoring during direct-acting antiviral therapy

    No full text
    Background: The COBAS AmpliPrep/COBAS TaqMan assay HCV (CAP/CTM) is widely used in clinical routine for HCV testing. Recently, the new cobas HCV test was established for high throughput testing with minimal operator intervention. As different assays may yield different quantitative/qualitative results that possibly impact treatment decisions, the aim of this study was to externally evaluate the cobas HCV test performance in comparison to CAP/CTM in a clinically relevant setting. Methods: Serum samples were obtained from 270 patients who received direct acting antiviral therapy with different treatment regimens at two study sites (Hannover and Frankfurt) in 2016. Overall, 1545 samples (baseline, on-treatment and follow-up) were tested in parallel by both assays. Results: The mean difference between cobas HCV and CAP/CTM for the quantification of HCV RNA was 0.008 log10 IU/ml HCV RNA (95% limits of agreement: -0.02–0.036) showing excellent agreement of both assays. With respect to clinical cut offs (HCV RNA detectable vs. target not detected and HCV RNA above the lower limit of quantification (LLOQ) vs. <LLOQ), discordant results were obtained in 9.5% and 4.6%, respectively; the greatest differences were observed during early stages of antiviral therapy (week 1, week 2 and week 4), but none were statistically significant. Overall percent agreement for SVR between cobas HCV and CAP/CTM at the 15 IU/ml cutoff was 99.2% (95%CI 92.7%-100%). Conclusion: The performance of the new cobas HCV test was comparable to CAP/CTM in a clinical setting representing a large patient population with HCV GT 1 and 3 treated with DAAs

    Utility of the new cobas HCV test for viral load monitoring during direct-acting antiviral therapy.

    No full text
    BackgroundThe COBAS AmpliPrep/COBAS TaqMan assay HCV (CAP/CTM) is widely used in clinical routine for HCV testing. Recently, the new cobas HCV test was established for high throughput testing with minimal operator intervention. As different assays may yield different quantitative/qualitative results that possibly impact treatment decisions, the aim of this study was to externally evaluate the cobas HCV test performance in comparison to CAP/CTM in a clinically relevant setting.MethodsSerum samples were obtained from 270 patients who received direct acting antiviral therapy with different treatment regimens at two study sites (Hannover and Frankfurt) in 2016. Overall, 1545 samples (baseline, on-treatment and follow-up) were tested in parallel by both assays.ResultsThe mean difference between cobas HCV and CAP/CTM for the quantification of HCV RNA was 0.008 log10 IU/ml HCV RNA (95% limits of agreement: -0.02-0.036) showing excellent agreement of both assays. With respect to clinical cut offs (HCV RNA detectable vs. target not detected and HCV RNA above the lower limit of quantification (LLOQ) vs. ConclusionThe performance of the new cobas HCV test was comparable to CAP/CTM in a clinical setting representing a large patient population with HCV GT 1 and 3 treated with DAAs

    Commutability and concordance of four hepatitis B virus DNA assays in an international multicenter study

    No full text
    Background HBV DNA is the most important molecular marker in hepatitis B, used to determine treatment indication and monitoring. Most patients require lifelong hepatitis B virus (HBV) management, thus viral load (VL) monitoring may be performed at different laboratories, with different HBV assays, which may result in different VL results. This multicenter study compares the commutability and concordance of results from four different HBV DNA assays: CAP/CTM HBVv2, HPS/CTM HBVv2 and the new cobas 6800/8800 HBV and cobas 4800 HBV assays. Methods Across all four assays, HBV limit of detection (LoD) and linearity at lower concentrations were assessed using panels traceable to the World Health Organization international standard, and concordance was investigated at the important medical decision cutoffs 2000 and 20,000 IU/ml, using specimens from HBV-positive patients. Results The calculated LoD via a probit curve was 2.7 IU/ml for cobas 6800/8800 HBV, 2.8 IU/ml for cobas 4800 HBV, 9.6 IU/ml for CAP/CTM HBVv2, and 6.2 IU/ml for HPS/CTM HBVv2. The average accuracy was comparable between cobas 6800/8800 HBV, cobas 4800 HBV and CAP/CTM HBVv2 (0.04–0.05 log 10 IU/ml), while a slightly lower accuracy was documented for HPS/CTM HBVv2 (−0.16 log 10 IU/ml). A total of 211–245 clinical samples were used for a pairwise comparison. Mean paired log differences ranged from −0.17 log 10 IU/ml to −0.01 log 10 IU/ml. Coefficient of determination was over 98% for all pairs with high overall percent agreement at the 2000 and 20,000 IU/ml cutoffs (from 91.7% to 96.3%). In a subset of samples with VL±0.5 log 10 to the 2000 and 20,000 IU/ml thresholds, concordance was still 72% and 82%, respectively. Conclusions The new cobas 6800/8800 HBV and 4800 HBV assays show high accuracy in samples with low-level viremia and a high concordance with the established HBV tests, CAP/CTM HBVv2 and HPS/CTM HBVv2, at 2000 and 20,000 IU/ml. Thus, all four HBV assays have high commutability and may be used interchangeably in routine clinical practice