18 research outputs found

    Travelling waves for the Gross-Pitaevskii equation II

    Full text link
    The purpose of this paper is to provide a rigorous mathematical proof of the existence of travelling wave solutions to the Gross-Pitaevskii equation in dimensions two and three. Our arguments, based on minimization under constraints, yield a full branch of solutions, and extend earlier results, where only a part of the branch was built. In dimension three, we also show that there are no travelling wave solutions of small energy.Comment: Final version accepted for publication in Communications in Mathematical Physics with a few minor corrections and added remark

    Boost operators in Coulomb-gauge QCD: the pion form factor and Fock expansions in phi radiative decays

    Get PDF
    In this article we rederive the Boost operators in Coulomb-Gauge Yang-Mills theory employing the path-integral formalism and write down the complete operators for QCD. We immediately apply them to note that what are usually called the pion square, quartic... charge radii, defined from derivatives of the pion form factor at zero squared momentum transfer, are completely blurred out by relativistic and interaction corrections, so that it is not clear at all how to interpret these quantities in terms of the pion charge distribution. The form factor therefore measures matrix elements of powers of the QCD boost and Moeller operators, weighted by the charge density in the target's rest frame. In addition we remark that the decomposition of the eta' wavefunction in quarkonium, gluonium, ... components attempted by the KLOE collaboration combining data from phi radiative decays, requires corrections due to the velocity of the final state meson recoiling against a photon. This will be especially important if such decompositions are to be attempted with data from J/psi decays.Comment: 14 pages, 4 figure

    Physics Opportunities with the 12 GeV Upgrade at Jefferson Lab

    Full text link
    This white paper summarizes the scientific opportunities for utilization of the upgraded 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab. It is based on the 52 proposals recommended for approval by the Jefferson Lab Program Advisory Committee.The upgraded facility will enable a new experimental program with substantial discovery potential to address important topics in nuclear, hadronic, and electroweak physics.Comment: 64 page

    Body weight-length relationships in giant otters (Pteronura brasiliensis) (Carnivora, Mustelidae)

    Get PDF
    Few giant otters (Pteronura brasiliensis) have been measured and weighed and its actual size is controversial in the literature. This study presents the weight-length relationship of Amazonian giant otters using 15 captive individuals. The maximum length and weight were 163cm and 22.5kg, and 162cm and 28.8kg, for the males and females, respectively. The weight-length relationships were not significantly different between the sexes (t = 0.658, d.f.=11, P>0.05) and can be expressed by the equation: W=1.48×10-5 L2.81. Considering that some of the giant otters used in this study were old individuals (more than 10 years old), and that all the animals analyzed were healthy, it is possible to assume that the weight-length relationships obtained are probably a close approximation of the relationship of giant otters of the Amazon region and can be used by institutions that keep this species in captivity as a base to quickly assess the animal's nutritive status. © 2009 Tecpar

    Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications

    No full text
    In single-isocenter stereotactic radiosurgery/radiotherapy (SRS/SRT) intracranial applications, multiple targets are being treated concurrently, often involving non-coplanar arcs, small photon beams and steep dose gradients. In search for more rigorous quality assurance protocols, this work presents and evaluates a novel methodology for patient-specific pre-treatment plan verification, utilizing 3D printing technology. In a patient's planning CT scan, the external contour and bone structures were segmented and 3D-printed using high-density bone-mimicking material. The resulting head phantom was filled with water while a film dosimetry insert was incorporated. Patient and phantom CT image series were fused and inspected for anatomical coherence. HUs and corresponding densities were compared in several anatomical regions within the head. Furthermore, the level of patient-to-phantom dosimetric equivalence was evaluated both computationally and experimentally. A single-isocenter multi-focal SRS treatment plan was prepared, while dose distributions were calculated on both CT image series, using identical calculation parameters. Phantom- and patient-derived dose distributions were compared in terms of isolines, DVHs, dose-volume metrics and 3D gamma index (GI) analysis. The phantom was treated as if the real patient and film measurements were compared against the patient-derived calculated dose distribution. Visual inspection of the fused CT images suggests excellent geometric similarity between phantom and patient, also confirmed using similarity indices. HUs and densities agreed within one standard deviation except for the skin (modeled as 'bone') and sinuses (water-filled). GI comparison between the calculated distributions resulted in passing rates better than 97% (1%/1 mm). DVHs and dose-volume metrics were also in satisfying agreement. In addition to serving as a feasibility proof-of-concept, experimental absolute film dosimetry verified the computational study results. GI passing rates were above 90%. Results of this work suggest that employing the presented methodology, patient-equivalent phantoms (except for the skin and sinuses areas) can be produced, enabling literally patient-specific pre-treatment plan verification in intracranial applications. © 2019 Institute of Physics and Engineering in Medicine

    Dosimetric performance of the Elekta Unity MR-linac system: 2D and 3D dosimetry in anthropomorphic inhomogeneous geometry

    No full text
    Following the clinical introduction of the Elekta Unity MR-linac, there is an urgent need for development of dosimetry protocols and tools, not affected by the presence of a magnetic field. This work presents a benchmarking methodology comprising 2D/3D passive dosimetry and involving on-couch adaptive treatment planning, a unique step in MR-linac workflows. Two identical commercially available 3D-printed head phantoms (featuring realistic bone anatomy and MR/CT contrast) were employed. One phantom incorporated a film dosimetry insert, while the second was filled with polymer gel. Gel dose-response characteristics were evaluated under the Unity irradiation and read-out conditions, using vials and a cubic container filled with gel from the same batch. Treatment plan for the head phantoms involved a hypothetical large C-shape brain lesion, partly surrounding the brainstem. An IMRT step-and-shoot 7-beam plan was employed. Pre-treatment on-couch MR-images were acquired in order for the treatment planning system to calculate the virtual couch shifts and perform adaptive planning. Absolute 2D and relative 3D measurements were compared against calculations related to both adapted and original plans. Real-time dose accumulation monitoring in the gel-filled phantom was also performed. Results from the vials and cubic container suggest that gel dose-response is linear in the dose range investigated and signal integrity is mature at the read-out timings considered. Head phantom 2D and 3D measurements agreed well with calculations with 3D gamma index passing rates above 90% in all cases, even with the most stringent criteria used (2 mm/2%). By exploiting the 3D information provided by the gel, comparison also involved DVHs, dose-volume and plan quality metrics, which also reflected the agreement between adapted and delivered plans within ±4%. No considerable discrepancies were detected between adapted and original plans. A novel methodology was developed and implemented, suitable for QA procedures in Unity. TPS calculations were validated within the experimental uncertainties involved. © 2019 Institute of Physics and Engineering in Medicine
    corecore