48,496 research outputs found

    Control of recollision wave packets for molecular orbital tomography using short laser pulses

    Full text link
    The tomographic imaging of arbitrary molecular orbitals via high-order harmonic generation requires that electrons recollide from one direction only. Within a semi-classical model, we show that extremely short phase-stabilized laser pulses offer control over the momentum distribution of the returning electrons. By adjusting the carrier-envelope phase, recollisions can be forced to occur from mainly one side, while retaining a broad energy spectrum. The signatures of the semi-classical distributions are observed in harmonic spectra obtained by numerical solution of the time-dependent Schr\"{o}dinger equation.Comment: 8 pages, 4 figures; v2: Added some extra clarifications; v3: minor grammatical change

    Konrad-Thaler-Gedächtnispreis der Arachnologischen Gesellschaft

    Get PDF
    Erstverleihung im Rahmen des Treffens der deutschsprachigen Arachnologen in Halle am 15.09.200

    An Efficient Beam Steerable Antenna Array Concept for Airborne Applications

    Get PDF
    Deployment of a satellite borne, steerable antenna array with higher directivity and gain in Low Earth Orbit makes sense to reduce ground station complexity and cost, while still maintaining a reasonable link budget. The implementation comprises a digitally beam steerable phased array antenna integrated with a complete system, comprising the antenna, hosting platform, ground station, and aircraft based satellite emulator to facilitate convenient aircraft based testing of the antenna array and ground-space communication link. This paper describes the design, development and initial successful interim testing of the various subsystems. A two element prototype used in this increases the signal-to-noise ratio (SNR) by 3 dB which is corresponding to more than 10 times better bit error rate (BER)

    Exploring the electron density in plasmas induced by extreme ultraviolet radiation in argon

    Get PDF
    The new generation of lithography tools use high energy EUV radiation which ionizes the present background gas due to photoionization. To predict and understand the long term impact on the highly delicate mirrors It is essential to characterize these kinds of EUV-induced plasmas. We measured the electron density evolution in argon gas during and just after irradiation by a short pulse of EUV light at 13.5 nm by applying microwave cavity resonance spectroscopy. Dependencies on EUV pulse energy and gas pressure have been explored over a range relevant for industrial applications. Our experimental results show that the maximum reached electron density depends linearly on pulse energy. A quadratic dependence - caused by photoionization and subsequent electron impact ionization by free electrons - is found from experiments where the gas pressure is varied. This is demonstrated by our theoretical estimates presented in this manuscript as well.Comment: submitted to J. Phys. D. 16 pages, 8 figure

    Surface acoustic wave modulation of single photon emission from GaN/InGaN nanowire quantum dots

    Get PDF
    On-chip quantum information processing requires controllable quantum light sources that can be operated on-demand at high-speeds and with the possibility of in-situ control of the photon emission wavelength and its optical polarization properties. Here, we report on the dynamic control of the optical emission from core-shell GaN/InGaN nanowire (NW) heterostructures using radio frequency surface acoustic waves (SAWs). The SAWs are excited on the surface of a piezoelectric lithium niobate crystal equipped with a SAW delay line onto which the NWs were mechanically transferred. Luminescent quantum dot (QD)-like exciton localization centers induced by compositional fluctuations within the InGaN nanoshell were identified using stroboscopic micro-photoluminescence (micro-PL) spectroscopy. They exhibit narrow and almost fully linearly polarized emission lines in the micro-PL spectra and a pronounced anti-bunching signature of single photon emission in the photon correlation experiments. When the nanowire is perturbed by the propagating SAW, the embedded QD is periodically strained and its excitonic transitions are modulated by the acousto-mechanical coupling, giving rise to a spectral fine-tuning within a ~1.5 meV bandwidth at the acoustic frequency of ~330 MHz. This outcome can be further combined with spectral detection filtering for temporal control of the emitted photons. The effect of the SAW piezoelectric field on the QD charge population and on the optical polarization degree is also observed. The advantage of the acousto-optoelectric over other control schemes is that it allows in-situ manipulation of the optical emission properties over a wide frequency range (up to GHz frequencies).Comment: arXiv admin note: text overlap with arXiv:1902.0791

    Time-and-motion tool for the assessment of working time in tuberculosis laboratories: a multicentre study

    Get PDF
    SETTING: Implementation of novel diagnostic assays in tuberculosis (TB) laboratory diagnosis requires effective management of time and resources. OBJECTIVE: To further develop and assess at multiple centres a time-and-motion (T&M) tool as an objective means for recording the actual time spent on running laboratory assays. DESIGN: Multicentre prospective study conducted in six European Union (EU) reference TB laboratories. RESULTS: A total of 1060 specimens were tested using four laboratory assays. The number of specimens per batch varied from one to 60; a total of 64 recordings were performed. Theoretical hands-on times per specimen (TTPS) in h:min:s for Xpert® MTB/RIF, mycobacterial interspersed repetitive unit-variable number of tandem repeats genotyping, Ziehl-Neelsen staining and manual fluorescence microscopy were respectively 00:33:02 ± 00:12:32, 00:13:34 ± 00:03:11, 00:09:54 ± 00:00:53 and 00:06:23 ± 00:01:36. Variations between laboratories were predominantly linked to the time spent on reporting and administrative procedures. Processing specimens in batches could help save time in highly automated assays (e.g., line-probe) (TTPS 00:14:00 vs. 00:09:45 for batches comprising 7 and 31 specimens, respectively). CONCLUSIONS: The T&M tool can be considered a universal and objective methodology contributing to workload assessment in TB diagnostic laboratories. Comparison of workload between laboratories could help laboratory managers justify their resource and personnel needs for the implementation of novel, time-saving, cost-effective technologies, as well as identify areas for improvement

    Weak Localization Thickness Measurements of Si:P Delta-Layers

    Full text link
    We report on our results for the characterization of Si:P delta-layers grown by low temperature molecular beam epitaxy. Our data shows that the effective thickness of a delta-layer can be obtained through a weak localization analysis of electrical transport measurements performed in perpendicular and parallel magnetic fields. An estimate of the diffusivity of phosphorous in silicon is obtained by applying this method to several samples annealed at 850 Celsius for intervals of zero to 15 minutes. With further refinements, this may prove to be the most precise method of measuring delta-layer widths developed to date, including that of Secondary Ion Mass Spectrometry analysis
    corecore