135 research outputs found

    Versatile lithium fluoride thin-film solid-state detectors for nanoscale radiation imaging

    Get PDF
    Point defects in insulating materials are successfully used for radiation detectors. Among them, colour centres in lithium fluoride (LiF) are well known for application in dosimeters and in light-emitting devices and lasers. LiF thin-film detectors for extreme ultraviolet radiation, soft and hard X-rays, based on photoluminescence from aggregate electronic defects, are currently under development for imaging application with laboratory radiation sources, e.g. laser-driven plasma sources and conventional X-ray tubes, as well as large-scale facilities, e.g. synchrotrons and free-electron lasers. Among the peculiarities of these detectors, noteworthy ones are the very high intrinsic spatial resolution ( 1 cm2) and the wide dynamic range. Moreover, they are insensitive to ambient light and no development process is needed. The latent images stored in the LiF thin layer can be read with fluorescence optical microscopy techniques. These detectors prove to be highly versatile, as LiF is sensitive to almost any kind of radiation, including charged particles and neutrons, and can be grown in the form of polycrystalline thin films, whose photoluminescence response can be tailored trough the control of the growth conditions

    VUV-Vis optical characterization of Tetraphenyl-butadiene films on glass and specular reflector substrates from room to liquid Argon temperature

    Full text link
    The use of efficient wavelength-shifters from the vacuum-ultraviolet to the photosensor's range of sensitivity is a key feature in detectors for Dark Matter search and neutrino physics based on liquid argon scintillation detection. Thin film of Tetraphenyl-butadiene (TPB) deposited onto the surface delimiting the active volume of the detector and/or onto the photosensor optical window is the most common solution in current and planned experiments. Detector design and response can be evaluated and correctly simulated only when the properties of the optical system in use (TPB film + substrate) are fully understood. Characterization of the optical system requires specific, sometimes sophisticated optical methodologies. In this paper the main features of TPB coatings on different, commonly used substrates is reported, as a result of two independent campaigns of measurements at the specialized optical metrology labs of ENEA and University of Tor Vergata. Measured features include TPB emission spectra with lineshape and relative intensity variation recorded as a function of the film thickness and for the first time down to LAr temperature, as well as optical reflectance and transmittance spectra of the TPB coated substrates in the wavelength range of the TPB emission

    Photoluminescence of radiation-induced color centers in lithium fluoride thin films for advanced diagnostics of proton beams

    Get PDF
    Systematic irradiation of thermally evaporated 0.8 μm thick polycrystalline lithium fluoride films on glass was performed by proton beams of 3 and 7 MeV energies, produced by a linear accelerator, in a fluence range from 1011 to 1015 protons/cm2. The visible photoluminescence spectra of radiation-induced F2 and F3+ laser active color centers, which possess almost overlapping absorption bands at about 450 nm, were measured under laser pumping at 458 nm. On the basis of simulations of the linear energy transfer with proton penetration depth in LiF, it was possible to obtain the behavior of the measured integrated photoluminescence intensity of proton irradiated LiF films as a function of the deposited dose. The photoluminescence signal is linearly dependent on the deposited dose in the interval from 103 to about 106 Gy, independently from the used proton energies. This behavior is very encouraging for the development of advanced solid state radiation detectors based on optically transparent LiF thin films for proton beam diagnostics and two-dimensional dose mapping

    High resolution and high efficiency coloration of lithium fluoride by soft X-rays irradiation

    Get PDF
    The efficient coloration of LiF material, in the form of bulk and films, by EUV and soft X-rays emitted by a laser-plasma source is demonstrated. The short penetration depth of soft-X-rays is exploited to obtain high spatial resolution luminescent patterns while the high dynamic range of proportionality between X-ray dose and coloration is exploited for using LiF as image detector in micro-radiography and soft X-ray microscopy applications

    Optical characterization of lithium fluoride thin-film imaging detectors for monochromatic hard X-rays

    Get PDF
    Lithium fluoride (LiF) crystals and thin films have been successfully investigated as X-ray imaging detectors based on optical reading of visible photoluminescence emitted by stable radiation-induced F2 and F+3 colour centres. In this work, the visible photoluminescence response of optically-transparent LiF film detectors of three different thicknesses, grown by thermal evaporation on Si(100) substrates and irradiated with monochromatic 7 keV X-rays at several doses in the range between 13 and 4.5 × 103 Gy, was carefully investigated by fluorescence optical microscopy. For all the film thicknesses, the photoluminescence response linearly depends on the irradiation dose in the investigated dose range. The lowest detected dose, delivered to the thinnest LiF film, only 0.5 μm thick, is estimated 13 Gy. Edge-enhancement imaging experiments, conducted by irradiating LiF film detectors at the same energy placing an Au mesh in front of them at a distance of 15 mm, allowed estimating a spatial resolution of (0.38 ± 0.05) μm, which is comparable to the microscope one. This very high spatial resolution in LiF film radiation detectors based on colour centres photoluminescence is combined with the availability of a wide field of view on large areas

    Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature

    Full text link
    Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photo multiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these testes the Hamamatsu PMTs showed superb performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments

    Lithium fluoride thin film detectors for low-energy proton beam diagnostics by photoluminescence of colour centres

    Get PDF
    Optically transparent LiF thin films thermally evaporated on glass and Si(100) substrates were used for advanced diagnostics of proton beams of energies from 1.4 to 7 MeV produced by a linear accelerator for protontheraphy under development at ENEA C.R. Frascati. The proton irradiation induces the formation of stable colour centres, among them the aggregate F2 and F3 + optically active defects. After exposure of LiF films grown on glass perpendicularly to the proton beams, their accumulated transversal spatial distributions were carefully measured by reading the latent two-dimensional (2-D) fluorescence images stored in the LiF thin layers by local formation of these broad-band visible light-emitting defects with an optical microscope under blue lamp excitation. Taking advantage from the low thickness of LiF thin films and from the linear behaviour of the integrated F2 and F3 + photoluminescence intensities up to the irradiation fluence of ~5x1015 p/cm2, placing a cleaved LiF film grown on Si substrate with the cutted edge perpendicular to the proton beam, the 2-D fluorescence image of the film surface could allow to obtain the depth profile of the energy released by protons, which mainly lose their energy at the end of the path

    thermoluminescence in lif crystals and the role of impurities

    Get PDF
    Eight nominally pure lithium fluoride crystals, obtained from a single LiF crystal containing less than 100 ppm impurities, were irradiated by gamma-rays from a 60 Co source at room temperature, with doses from 8.4 to 2.5 x 10 5 Gy, but one at -60 °C. Optical density measurements were performed to investigate the radiation-induced color centres (CCs) and to evaluate their concentrations. Thermoluminescence (TL) glow curves were collected and simulated by a first-order kinetics approach, and from the best-fit procedure ten glow peaks (GPs) spanning from 100 to 450 °C were highlighted. A comparative analysis of GP intensities and CC concentrations as a function of the irradiation dose has questioned their association as obtained in previous measurements, showing the impurities, less than 10 18 cm -3 , still playing a predominant role in TL spectra. New measurements on LiF crystals more pure, at least an order of magnitude, are required to establish for sure the association of GPs to CCs

    Lithium fluoride coloration by laser-plasma soft x-rays: A promising tool for X-ray microscopy and photonics

    Get PDF
    A new imaging detector for EUV or soft-X-ray radiation based on optically stimulated luminescence (OSL) of lithium fluoride (LiF) films or crystals is presented. The first micro-radiography images of biological samples and of meshes obtained on LiF using a laser-plasma source or an X-ray laser are shown, and (up to now) a resolution better than one micron is demonstrated. The dependence of the coloration density vs the deposited X-ray dose is considered and the advantages of this new diagnostic technique for both coherent and non-coherent EUV sources, compared with CCDs detectors, photographic films and photoresists are discussed. This new detector is extremely suitable for laser plasmas and for X-ray lasers sources

    Utility of percutaneous lung biopsy for diagnosing filamentous fungal infections in hematologic malignancies

    Get PDF
    Background and Objectives. The incidence of invasive filamentous fungal infections in hematologic patients is increasing as a consequence of high dose chemotherapy and bone marrow transplant procedures. Mortality is usually very high. The diagnosis is often difficult and yet a fast, accurate diagnosis is of fundamental importance for treating the infection and planning subsequent management of the hematologic disease. We evaluated the sensitivity of computed tomography (CT)-guided percutaneous biopsy in diagnosing pulmonary fungal infections. Design and Methods. Between 1997 and 2002 we performed 17 CT-guided percutaneous transthoracic lung biopsies in 17 hematologic patients with suspected filamentous fungi infection with negative BAL, to obtain a certain diagnosis and to know what species of fungi was responsible for infection. In all cases suspected mycosis began during the post-chemotherapy aplastic period. Patients were receiving antifungal therapy at the time of all biopsies. When the platelet count rose above 50 7109/L, CT-guided percutaneous lung biopsy with fine-needle aspiration for cytology was performed. Results. Twelve of 17 patients had histologic confirmation of the fungal infection (70.5%), 8 with Aspergillus spp. 4 with Mucorales spp. Biopsies provided non-specific results in 4 cases; in 2 of these cases, clinical course and response to therapy confirmed the diagnosis of mycosis; in the last case bronchoalveolar carcinoma was found as a new diagnosis. Cultures were positive in only 6 cases, all for Aspergillus spp. The sensitivity of CT-guided percutaneous lung biopsy was 70.6% and its positive predictive value (PPV) was 100%. This procedure provided an immediate diagnosis and only one side-effect (1 pneumothorax, without complications). Interpretation and Conclusions. Histologic discrimination between aspergillosis and mucormycosis is very important for deciding secondary prophylaxis during transplant procedures, because Mucor is usually resistant to azoles
    • …
    corecore