82 research outputs found

    Fast Detection of SARS-CoV-2 RNA Directly from Respiratory Samples Using a Loop-Mediated Isothermal Amplification (LAMP) Test

    Get PDF
    The availability of simple SARS-CoV-2 detection methods is crucial to contain the COVID-19 pandemic. This study examined whether a commercial LAMP assay can reliably detect SARS-CoV-2 genomes directly in respiratory samples without having to extract nucleic acids (NA) beforehand. Nasopharyngeal swabs (NPS, n = 220) were tested by real-time reverse transcription (RT)-PCR and with the LAMP assay. For RT-PCR, NA were investigated. For LAMP, NA from 26 NPS in viral transport medium (VTM) were tested. The other 194 NPS were analyzed directly without prior NA extraction (140 samples in VTM; 54 dry swab samples stirred in phosphate buffered saline). Ten NPS were tested directly by LAMP using a sous-vide cooking unit. The isothermal assay demonstrated excellent specificity (100%) but moderate sensitivity (68.8%), with a positive predictive value of 1 and a negative predictive value of 0.65 for direct testing of NPS in VTM. The use of dry swabs, even without NA extraction, improved the analytical sensitivity; up to 6% of samples showed signs of inhibition. LAMP could be performed successfully with a sous-vide cooking unit. This technique is very fast, requires little laboratory resources, and can replace rapid antigen tests or verify reactive rapid tests on-site

    On the Mechanism of Time--Delayed Feedback Control

    Full text link
    The Pyragas method for controlling chaos is investigated in detail from the experimental as well as theoretical point of view. We show by an analytical stability analysis that the revolution around an unstable periodic orbit governs the success of the control scheme. Our predictions concerning the transient behaviour of the control signal are confirmed by numerical simulations and an electronic circuit experiment.Comment: 4 pages, REVTeX, 4 eps-figures included Phys. Rev. Lett., in press also available at http://athene.fkp.physik.th-darmstadt.de/public/wolfram.htm

    The new Felsenkeller 5 MV underground accelerator

    Full text link
    The field of nuclear astrophysics is devoted to the study of the creation of the chemical elements. By nature, it is deeply intertwined with the physics of the Sun. The nuclear reactions of the proton-proton cycle of hydrogen burning, including the 3He({\alpha},{\gamma})7Be reaction, provide the necessary nuclear energy to prevent the gravitational collapse of the Sun and give rise to the by now well-studied pp, 7Be, and 8B solar neutrinos. The not yet measured flux of 13N, 15O, and 17F neutrinos from the carbon-nitrogen-oxygen cycle is affected in rate by the 14N(p,{\gamma})15O reaction and in emission profile by the 12C(p,{\gamma})13N reaction. The nucleosynthetic output of the subsequent phase in stellar evolution, helium burning, is controlled by the 12C({\alpha},{\gamma})16O reaction. In order to properly interpret the existing and upcoming solar neutrino data, precise nuclear physics information is needed. For nuclear reactions between light, stable nuclei, the best available technique are experiments with small ion accelerators in underground, low-background settings. The pioneering work in this regard has been done by the LUNA collaboration at Gran Sasso/Italy, using a 0.4 MV accelerator. The present contribution reports on a higher-energy, 5.0 MV, underground accelerator in the Felsenkeller underground site in Dresden/Germany. Results from {\gamma}-ray, neutron, and muon background measurements in the Felsenkeller underground site in Dresden, Germany, show that the background conditions are satisfactory for nuclear astrophysics purposes. The accelerator is in the commissioning phase and will provide intense, up to 50{\mu}A, beams of 1H+, 4He+ , and 12C+ ions, enabling research on astrophysically relevant nuclear reactions with unprecedented sensitivity.Comment: Submitted to the Proceedings of the 5th International Solar Neutrino Conference, Dresden/Germany, 11-14 June 2018, to appear on World Scientific -- updated version (Figure 2 and relevant discussion updated, co-author A. Domula added

    Restricted feedback control of one-dimensional maps

    Full text link
    Dynamical control of biological systems is often restricted by the practical constraint of unidirectional parameter perturbations. We show that such a restriction introduces surprising complexity to the stability of one-dimensional map systems and can actually improve controllability. We present experimental cardiac control results that support these analyses. Finally, we develop new control algorithms that exploit the structure of the restricted-control stability zones to automatically adapt the control feedback parameter and thereby achieve improved robustness to noise and drifting system parameters.Comment: 29 pages, 9 embedded figure

    Review

    No full text

    Purification and analysis of partially alkylated cyclodextrins by liquid and gas chromatography

    No full text
    Complex mixtures of partially alkylated cyclodextrins can be analyzed by both HPLC and high temperature capillary GC. Because of the limited efficiency of LC, suitable analytical and preparative separations can be achieved only with systems of carefully optimized selectivity. Using LC it has been possible to isolate and purify single cyclodextrin species from very complex mixtures of components which contain unreacted hydroxyl groups in addition to the alkoxy groups. Analysis of the reaction mixtures and of fractions taken from LC separations can be performed with advantage by high resolution capillary GC at high temperatures between 300 and 400 °C. The thermal stability of partially alkylated cyclodextrins in high temperature GC is considerably increased by trimethylsilylation of the free hydroxyl groups. Fast atom bombardment mass spectrometry and proton NMR were used to identify species isolated from the preparative LC separations

    Preparation, purification, and analysis of alkylated cyclodextrins

    No full text
    Methods of alkylation of α-, β- and γ-cyclodextrins have been optimized with regard to the parameters of reaction, degree of alkylation and yields. The analysis of the reaction mixtures and of the isolated single species has been performed by high temperature GC and HPLC. The phase systems of the preferably applied HPLC have been carefully adjusted by variation of both the stationary and mobile phases to the very different hydrophobicities of the various alkylated CD species which have been synthesized. Several partially or fully alkylated CD species were isolated from preparative scale HPLC separations in high purity
    corecore